Variation in the position of the elbow flexion axis after total joint replacement with three different prostheses.

The instantaneous flexion axes in rheumatoid patients treated with a Kudo (Biomet UK Ltd, Swindon, UK), Capitellocondylar (Johnson & Johnson Orthopaedics Inc, Raynham, MA), or GSB III (Zimmer GmbH, Winterthur, Switzerland) elbow prosthesis were calculated using radiostereometric analysis and compared with those previously found in the normal elbow in vivo. Variability in the flexion axis position was greater in the prosthetic elbows than reported for healthy subjects. This was especially evident for the unlinked Kudo prosthesis, with dispersions of the axes up to 84.3 degrees in the frontal and 45.0 degrees in the horizontal plane. Corresponding values for the unlinked Capitellocondylar prosthesis were 19.7 degrees and 20.9 degrees. The linked GSB III prosthesis was the most constrained, with dispersions within 15.4 degrees in the frontal and 4.6 degrees in the horizontal plane. The unlinked elbow prostheses displayed considerable axis dispersion under physiologic conditions. Implant design seems to be able to compensate for this to some extent, as indicated, for example, by the results of the Capitellocondylar prosthesis.

[1]  K. An,et al.  Role of collateral ligaments in the GSB-linked total elbow prosthesis. , 2001, Journal of shoulder and elbow surgery.

[2]  G L Niebur,et al.  Motion and laxity of the capitellocondylar total elbow prosthesis. , 1994, The Journal of bone and joint surgery. American volume.

[3]  K. An,et al.  In vitro stability of an unconstrained total elbow prosthesis. Influence of axial loading and joint flexion angle. , 1993, The Journal of arthroplasty.

[4]  K. An,et al.  Intrinsic constraint of unlinked total elbow replacements--the ulnotrochlear joint. , 2005, The Journal of bone and joint surgery. American volume.

[5]  Kai-Nan An Kinematics and constraint of total elbow arthroplasty. , 2005, Journal of shoulder and elbow surgery.

[6]  J. O. Søjbjerg,et al.  Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture: efficacy of prosthetic replacement and ligament repair. , 2005, Journal of shoulder and elbow surgery.

[7]  Bernard F. Morrey,et al.  The Elbow and Its Disorders , 2000 .

[8]  B F Morrey,et al.  Loose-hinge total elbow arthroplasty. An experimental study of the effects of implant alignment on three-dimensional elbow kinematics. , 1995, The Journal of arthroplasty.

[9]  A. Carr,et al.  Total elbow arthroplasty: a systematic review of the literature in the English language until the end of 2003. , 2005, The Journal of bone and joint surgery. British volume.

[10]  K Knutson,et al.  The Swedish Knee Arthroplasty Register 1975-1997: An update with special emphasis on 41,223 knees operated on in 1988-1997 , 2001, Acta orthopaedica Scandinavica.

[11]  Hideki Yoshikawa,et al.  In vivo elbow biomechanical analysis during flexion: three-dimensional motion analysis using magnetic resonance imaging. , 2004, Journal of shoulder and elbow surgery.

[12]  K. An,et al.  Kinematics of semi-constrained total elbow arthroplasty. , 1992, The Journal of bone and joint surgery. British volume.

[13]  P Herberts,et al.  Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases , 2000, Acta orthopaedica Scandinavica.

[14]  A. Lundberg,et al.  Variation in the position and orientation of the elbow flexion axis. , 2003, The Journal of bone and joint surgery. British volume.

[15]  K. An,et al.  Malrotation of the humeral component of the capitellocondylar total elbow replacement is not the sole cause of dislocation , 1994, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[16]  James A. Johnson,et al.  The effect of radial head excision and arthroplasty on elbow kinematics and stability. , 2004, The Journal of bone and joint surgery. American volume.