Spatio-temporal (2D+T) non-rigid registration of real-time 3D echocardiography and cardiovascular MR image sequences
暂无分享,去创建一个
Harald Becher | Weiwei Zhang | J Alison Noble | J Michael Brady | J. Brady | J. Noble | H. Becher | Weiwei Zhang
[1] Nicholas Ayache,et al. Polyrigid and polyaffine transformations: A novel geometrical tool to deal with non-rigid deformations - Application to the registration of histological slices , 2005, Medical Image Anal..
[2] Hany Farid,et al. Elastic registration in the presence of intensity variations , 2003, IEEE Transactions on Medical Imaging.
[3] Michael Brady,et al. Real time 3-D ultrasound to MR cardiovascular image registration using a phase-based approach , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..
[4] Richard D. White,et al. ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. , 2010, Circulation.
[5] Matthew D Robson,et al. Computerised planning of the acquisition of cardiac MR images. , 2004, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.
[6] Accf Task Force Members. ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance A Report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents , 2010 .
[7] J. Alison Noble,et al. 2D+T Acoustic Boundary Detection in Echocardiography , 1998, MICCAI.
[8] Michael Brady,et al. Colorectal MRI image registration using phase mutual information from non-parametric probability density function estimator , 2008, 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.
[9] L. Sugeng,et al. Real-time 3-dimensional echocardiography: an integral component of the routine echocardiographic examination in adult patients? , 2009, Circulation.
[10] J. Hilgert. A Connected Lie Group Equals the Square of the Exponential Image , 2003 .
[11] Michael Brady,et al. Non-Parametric Mixture Model Based Evolution of Level Sets and Application to Medical Images , 2007, 2007 International Conference on Computing: Theory and Applications (ICCTA'07).
[12] Max A. Viergever,et al. A survey of medical image registration , 1998, Medical Image Anal..
[13] Michael Brady,et al. Spatio-temporal Registration of Real Time 3D Ultrasound to Cardiovascular MR Sequences , 2007, MICCAI.
[14] Hyunjin Park,et al. Adaptive registration using local information measures , 2004, Medical Image Anal..
[15] Max A. Viergever,et al. Mutual-information-based registration of medical images: a survey , 2003, IEEE Transactions on Medical Imaging.
[16] David J. Hawkes,et al. Registration of freehand 3D ultrasound and magnetic resonance liver images , 2004, Medical Image Anal..
[17] Daniel Rueckert,et al. Fast Spatio-temporal Free-Form Registration of Cardiac MR Image Sequences , 2004, FIMH.
[18] Michael Brady,et al. Adaptive Non-rigid Registration of Real Time 3D Ultrasound to Cardiovascular MR Images , 2007, IPMI.
[19] Kashif Rajpoot,et al. Multiview RT3D Echocardiography Image Fusion , 2009, FIMH.
[20] Manesh R. Patel,et al. ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. , 2010, Circulation.
[21] Jing Ren,et al. Rapid registration of multimodal images using a reduced number of voxels , 2006, SPIE Medical Imaging.
[22] Michael Brady,et al. Non-parametric Mixture Model Based Evolution of Level Sets , 2007, ICCTA.
[23] J. Alison Noble,et al. 2D+T acoustic boundary detection in echocardiography , 2000, Medical Image Anal..
[24] Nicholas Ayache,et al. Rigid registration of 3-D ultrasound with MR images: a new approach combining intensity and gradient information , 2001, IEEE Transactions on Medical Imaging.
[25] J. Alison Noble,et al. Registration of Multiview Real-Time 3-D Echocardiographic Sequences , 2007, IEEE Transactions on Medical Imaging.
[26] María J. Ledesma-Carbayo,et al. Cardiac Motion Analysis from Ultrasound Sequences Using Non-rigid Registration , 2001, MICCAI.
[27] Michael Felsberg,et al. The monogenic signal , 2001, IEEE Trans. Signal Process..
[28] Patrick Clarysse,et al. A review of cardiac image registration methods , 2002, IEEE Transactions on Medical Imaging.
[29] Michael Felsberg,et al. A New Extension of Linear Signal Processing for Estimating Local Properties and Detecting Features , 2000, DAGM-Symposium.
[30] M. Wüstner. A Connected Lie Group Equals the Square of the Exponential Image , 2002 .
[31] Jing Ren,et al. Dynamic 3D Ultrasound and MR Image Registration of the Beating Heart , 2005, MICCAI.
[32] Michael Jerosch-Herold,et al. Expert Consensus Document Accf/acr/aha/nasci/scmr 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance a Report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents Writing Committee Members Expert Consensus Document Table of Contents Hundley Et Al , 2010 .
[33] Michael Brady,et al. Phase mutual information as a similarity measure for registration , 2005, Medical Image Anal..
[34] V.R.S Mani,et al. Survey of Medical Image Registration , 2013 .
[35] K. Rhode,et al. Echocardiography to magnetic resonance image registration for use in image-guided cardiac catheterization procedures. , 2009, Physics in medicine and biology.