Simultaneous continuous recording of accommodation and pupil size using the modified Shin‐Nippon SRW‐5000 autorefractor

The internal optics of the recent models of the Shin‐Nippon SRW‐5000 autorefractor (also marketed as the Grand Seiko WV‐500) have been modified by the manufacturer so that the infrared measurement ring has been replaced by pairs of horizontal and vertical infrared bars, on either side of fixation. The binocular, open field‐of‐view, allowing the accommodative state to be objectively monitored while a natural environment is viewed, has made the SRW‐5000 a valuable tool in further understanding the nature of the oculomotor response. It is shown that the root‐mean‐square of model eye measures was least (0.017 ± 0.002D) when the separation of the horizontal measurement bars were averaged twice. The separation of the horizontal bars changes by 3.59 pixels/dioptre (r2 = 0.99), allowing continuous on‐line analysis of the refractive state at up to 60 Hz temporal resolution to an accuracy of <0.001D, with pupils >3 mm. The pupil edge is not obscured in the diagonal axis by the measurement bars, unlike the ring of the original optics, so in the newer model pupil size can be measured simultaneously at the same rate with a resolution of <0.001 mm. The measurements of accommodation and pupil size are relatively unaffected by eccentricity of viewing up to ±10° from the visual axis and instrument focusing inaccuracies over a range of 10 mm towards the eye and 5 mm away from the eye. The resolution and temporal properties of the analysis are therefore ideal for the simultaneous measurement of dynamic accommodation and pupil responses.

[1]  M Millodot,et al.  Clinical evaluation of the Canon Autoref R-1. , 1985, American journal of optometry and physiological optics.

[2]  J S Wolffsohn,et al.  Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adults. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[3]  J. McLaren,et al.  Computerized analysis of pupillograms in studies of alertness. , 1992, Investigative ophthalmology & visual science.

[4]  Joanne Wood,et al.  Microfluctuations of steady-state accommodation and the cardiopulmonary system , 1995, Vision Research.

[5]  S. Chat,et al.  Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in children. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[6]  M Millodot,et al.  The relationship between tonic accommodation and refractive error. , 1987, Investigative ophthalmology & visual science.

[7]  B. Gilmartin,et al.  The effect of pupil size on static and dynamic measurements of accommodation using an infra‐red optometer , 1989, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[8]  J R Pugh,et al.  Modification of the Canon Auto Ref R1 for use as a continuously recording infra‐red optometer , 1988, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[9]  J. Wolffsohn,et al.  Clinical Evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K Autorefractor , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[10]  J S Wolffsohn,et al.  Continuous recording of accommodation and pupil size using the Shin-Nippon SRW-5000 autorefractor. , 2001, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.