Three‐dimensional motion tracking for high‐resolution optical microscopy, in vivo

When conducting optical imaging experiments, in vivo, the signal to noise ratio and effective spatial and temporal resolution is fundamentally limited by physiological motion of the tissue. A three‐dimensional (3D) motion tracking scheme, using a multiphoton excitation microscope with a resonant galvanometer, (512 × 512 pixels at 33 frames s−1) is described to overcome physiological motion, in vivo. The use of commercially available graphical processing units permitted the rapid 3D cross‐correlation of sequential volumes to detect displacements and adjust tissue position to track motions in near real‐time. Motion phantom tests maintained micron resolution with displacement velocities of up to 200 μm min−1, well within the drift observed in many biological tissues under physiologically relevant conditions. In vivo experiments on mouse skeletal muscle using the capillary vasculature with luminal dye as a displacement reference revealed an effective and robust method of tracking tissue motion to enable (1) signal averaging over time without compromising resolution, and (2) tracking of cellular regions during a physiological perturbation.

[1]  R. Balaban,et al.  Multi‐photon excitation microscopy in intact animals , 2006, Journal of microscopy.

[2]  R. Balaban,et al.  Skeletal muscle NAD(P)H two-photon fluorescence microscopy in vivo: topology and optical inner filters. , 2005, Biophysical journal.

[3]  Olivier D. Faugeras,et al.  Flows of diffeomorphisms for multimodal image registration , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[4]  Ian Parker,et al.  Real-time imaging of lymphocytes in vivo. , 2003, Current opinion in immunology.

[5]  Ruben M Sandoval,et al.  Functional Studies of the Kidney of Living Animals Using Multicolor 2-photon Microscopy , 2022 .

[6]  Olivier D. Faugeras,et al.  Variational Methods for Multimodal Image Matching , 2002, International Journal of Computer Vision.

[7]  A. Hudetz,et al.  Blood Flow in the Cerebral Capillary Network: A Review Emphasizing Observations with Intravital Microscopy , 1997, Microcirculation.

[8]  R S Balaban,et al.  Optimizing multiphoton fluorescence microscopy light collection from living tissue by noncontact total emission detection (epiTED) , 2011, Journal of microscopy.

[9]  Jay R Knutson,et al.  Optimization of multiphoton excitation microscopy by total emission detection using a parabolic light reflector , 2007, Journal of microscopy.

[10]  B. O’Rourke,et al.  Two-Photon Microscopy of Cells and Tissue , 2004 .

[11]  L Leybaert,et al.  A simple and practical method to acquire geometrically correct images with resonant scanning‐based line scanning in a custom‐built video‐rate laser scanning microscope , 2005, Journal of microscopy.

[12]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[13]  C. Stosiek,et al.  In vivo two-photon calcium imaging of neuronal networks , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[14]  C. Chefd'Hotel,et al.  Short Communication: Subcellular Motion Compensation for Minimally Invasive Microscopy, In Vivo: Evidence for Oxygen Gradients in Resting Muscle , 2010, Circulation research.

[15]  P. Poole‐Wilson,et al.  Hypoxia and calcium. , 1979, Journal of molecular and cellular cardiology.

[16]  R. A. Howlett,et al.  Effect of hypoxia on fatigue development in rat muscle composed of different fibre types , 2007, Experimental physiology.