Correlation between PDIV and life distribution under different testing waveforms

The implementation of underground distribution lines has grown significantly over the last decades due to the rapid increase of electric energy demands. But, the lifetime distribution of lines is strongly affected by the single or multiple stresses that could develop in the insulation system of the power cables. In this paper, the influence of applied voltage waveform on partial discharge activity and lifetime distribution of insulation material for power cables was investigated. In this sense, the Inverse Power Law-Weibull model was applied in order to develop a life model of the PD induced degradation processes under different voltage waveforms occurring in micro-cavities from the power cables insulation system. For the insulation design it is of great importance to assess the insulation threshold by using the voltage tests. As result, the step-up test method was used.

[1]  Hideo Hirose,et al.  Estimation for the Weibull Power Law Parameters in the Step-up Voltage Test , 2009, Eng. Lett..

[2]  D. Wald,et al.  Evolution of Medium Voltage Cable Technology in Europe , 2008, IEEE Electrical Insulation Magazine.

[3]  E. Helerea,et al.  Enhancing reliability for medium voltage underground power lines , 2011, 2011 7TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE).

[4]  L. Niemeyer,et al.  Measurement and simulation of PD in epoxy voids , 1995 .

[5]  L. Niemeyer A generalized approach to partial discharge modeling , 1995 .

[6]  Gian Carlo Montanari,et al.  Patterns of partial discharge activity in XLPE: From inception to breakdown , 2010, 2010 10th IEEE International Conference on Solid Dielectrics.

[7]  Gian Carlo Montanari,et al.  Theoretical and experimental derivation of partial discharge height distribution models , 1999, 1999 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.99CH36319).

[8]  R. Bodega,et al.  Partial discharge detection using oscillating voltage at different frequencies , 2002, IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276).

[9]  Gian Carlo Montanari,et al.  Relation between the trend of partial discharges and aging models under AC voltage , 2009, 2009 IEEE 9th International Conference on the Properties and Applications of Dielectric Materials.

[10]  Hernandez Mejia,et al.  Characterization of real power cable defects by diagnostic measurements , 2008 .

[11]  A. Cavallini,et al.  Effect of supply voltage frequency on testing of insulation system , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.