Design of Pressure Sensor Arrays to Assess Electrode Contact Pressure During In Vivo Recordings in the Gut*

The gastrointestinal (GI) tract is in part controlled by slow wave electrical activity. Recordings of slow waves with high-resolution (HR) electrode arrays are used to characterize normal and abnormal conduction pathways. Improving the quality of these electrical recordings is important for developing a better understanding of abnormal activity. Contact pressure is one factor that can affect the quality of electrical recordings. We compared the performance of two pressure sensing devices for measuring HR electrode array contact pressure. A Velostat-based sensor array was custom designed and built in a 4 × 2 conguration (area: 30 mm2 per sensor) to be integrated into electrical recordings. Commercially available FlexiForce A201 sensors were used to compare to the Velostat-based sensors. Benchtop testing of these sensors was performed; the error of the Velostat-based sensors (14−31%) was better than that of the FlexiForce sensors (20−49%) within a range of 2666−6666 Pa. The Velostat-based sensors were also more repeatable than the FlexiForce sensors over the same pressure range. Simultaneous pressure and slow wave recordings were performed in vivo on a rabbit small intestine. The Velostat-based sensors were able to resolve spatiotemporal changes in contact pressure in the range of 0−10 000 Pa.

[1]  Leo K. Cheng,et al.  Methods for High-Resolution Electrical Mapping in the Gastrointestinal Tract , 2019, IEEE Reviews in Biomedical Engineering.

[2]  G. O’Grady,et al.  Comparison of filtering methods for extracellular gastric slow wave recordings , 2013, Neurogastroenterology and motility : the official journal of the European Gastrointestinal Motility Society.

[3]  Leo K. Cheng,et al.  Dynamic slow‐wave interactions in the rabbit small intestine defined using high‐resolution mapping , 2019, Neurogastroenterology and Motility.

[4]  Leonel Paredes-Madrid,et al.  Underlying Physics of Conductive Polymer Composites and Force Sensing Resistors (FSRs). A Study on Creep Response and Dynamic Loading , 2017, Materials.

[5]  Leo K. Cheng,et al.  Loss of Interstitial Cells of Cajal and Patterns of Gastric Dysrhythmia in Patients With Chronic Unexplained Nausea and Vomiting. , 2015, Gastroenterology.

[6]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[7]  Leo K. Cheng,et al.  The gastrointestinal electrical mapping suite (GEMS): software for analyzing and visualizing high-resolution (multi-electrode) recordings in spatiotemporal detail , 2012, BMC Gastroenterology.

[8]  H. Zakaria,et al.  Low-Cost Pressure Sensor Matrix Using Velostat , 2017, 2017 5th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME).

[9]  Leo K. Cheng,et al.  Gastrointestinal system , 2010, Wiley interdisciplinary reviews. Systems biology and medicine.

[10]  Stylianos Siskos,et al.  A Signal Conditioning Circuit for Piezoresistive Pressure Sensors With Variable Pulse-Rate Output , 2000 .

[11]  Steve Rothberg,et al.  Evaluation of thin, flexible sensors for time-resolved grip force measurement , 2007 .

[12]  Alher Mauricio Hernández-Valdivieso,et al.  Test and fabrication of piezoresistive sensors for contact pressure measurement , 2017 .

[13]  Adrian D. C. Chan,et al.  Effect of Pressure on Skin-Electrode Impedance in Wearable Biomedical Measurement Devices , 2018, IEEE Transactions on Instrumentation and Measurement.

[14]  W. Lammers,et al.  Spatiotemporal electrical and motility mapping of distension-induced propagating oscillations in the murine small intestine. , 2005, American journal of physiology. Gastrointestinal and liver physiology.

[15]  P. Nielsen,et al.  High-resolution Mapping of In Vivo Gastrointestinal Slow Wave Activity Using Flexible Printed Circuit Board Electrodes: Methodology and Validation , 2009, Annals of Biomedical Engineering.