Placement of Endosteal Implants in the Zygoma after Maxillectomy: A Cadaver Study Using Surgical Navigation

Endosteal implants facilitate obturator prosthesis fixation in tumor patients after maxillectomy. Previous clinical studies have shown, however, that the survival of implants placed into available bone after maxillectomy is generally poor. Nevertheless, implants positioned optimally in residual zygomatic bone provide superior stability from a biomechanical point of view. In a pilot study, the authors assessed the precision of VISIT, a computer‐aided surgical navigation system dedicated to the placement of endosteal implants in the maxillofacial area. Five cadaver specimens underwent hemimaxillectomy. The cadaver head was matched to a preoperative high‐resolution computed tomograph by using implanted surgical microscrews as fiducial markers. The position of a surgical drill relative to the cadaver head was determined with an optical tracking system. Implants were placed into the zygomatic arch, where maximum bone volume was available. The results were assessed using tests for localization accuracy and postoperative computed tomographic scans of the cadaver specimens. The localization accuracy of landmarks on the bony skull was 0.6 ± 0.3 mm (average ± SD), as determined with a 5‐df pointer probe; the localization accuracy of the tip of the implant burr was 1.7 ± 0.4 mm. The accuracy of the implant position compared with the planned position was 1.3 ± 0.8 mm for the external perforation of the zygoma and 1.7 ±1.3 mm for the internal perforation. Eight of 10 implants were inserted with maximal contact to surrounding bone, and two implants were located unfavorably. Reliable placement of implants in this region is difficult to achieve. The technique described in this article may be very helpful in the management of patients after maxillary resection with poor support for obturator prostheses. (Plast. Reconstr. Surg. 107: 659, 2001.)

[1]  J J Gary,et al.  Rehabilitation with calvarial bone grafts and osseointegrated implants after partial maxillary resection: a clinical report. , 1992, The Journal of prosthetic dentistry.

[2]  O. Ganslandt,et al.  Technical accuracy of a neuronavigation system measured with a high-precision mechanical micromanipulator. , 1997, Neurosurgery.

[3]  A Wagner,et al.  Computer-aided navigation in secondary reconstruction of post-traumatic deformities of the zygoma. , 1997, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[4]  P J Mentag,et al.  Increased retention of a maxillary obturator prosthesis using osteointegrated intramobile cylinder dental implants: A clinical report. , 1988, The Journal of prosthetic dentistry.

[5]  Ann Fyler,et al.  Bilateral Maxillectomy and Midfacial Reconstruction , 1995, The Annals of otology, rhinology, and laryngology.

[6]  D Schettler,et al.  Titanium implants in the zygoma as retaining elements after hemimaxillectomy. , 1997, The International journal of oral & maxillofacial implants.

[7]  W Birkfellner,et al.  Computer-aided surgery in distraction osteogenesis of the maxilla and mandible. , 1999, International journal of oral and maxillofacial surgery.

[8]  S M Parel,et al.  Osseointegration in maxillofacial prosthetics. Part I: Intraoral applications. , 1986, The Journal of prosthetic dentistry.

[9]  S. James Zinreich,et al.  An optical 3D digitizer for frameless stereotactic surgery , 1996, IEEE Computer Graphics and Applications.

[10]  M Ueda,et al.  Maxillary obturator supported by osseointegrated implants placed in irradiated bone: report of cases. , 1993, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[11]  C Giorgi,et al.  A computer controlled stereotactic arm: virtual reality in neurosurgical procedures. , 1993, Acta neurochirurgica. Supplementum.

[12]  Russell H. Taylor,et al.  Computer-Integrated Surgery: Technology and Clinical Applications , 1995 .

[13]  F L Bookstein,et al.  Three‐Dimensional Computer‐Assisted Design of Craniofacial Surgical Procedures: Optimization and Interaction with Cephalometric and CT‐Based Models , 1986, Plastic and reconstructive surgery.

[14]  H Bergmann,et al.  Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method. , 1999, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[15]  D van Steenberghe,et al.  Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. , 1992, Clinical oral implants research.

[16]  Ismail Jy,et al.  Osseointegration in maxillofacial prosthetics. , 1990 .

[17]  R. Acland,et al.  The Osteocutaneous Scapular Flap for Mandibular and Maxillary Reconstruction , 1986, Plastic and reconstructive surgery.

[18]  J G McCarthy,et al.  A virtual reality system for bone fragment positioning in multisegment craniofacial surgical procedures. , 1998, Plastic and reconstructive surgery.

[19]  Berthold K. P. Horn,et al.  Closed-form solution of absolute orientation using unit quaternions , 1987 .

[20]  Junaida Ismail,et al.  Osseointegration in maxillofacial prosthetics. , 1990, Dental clinics of North America.

[21]  H. Obwegeser,et al.  Late reconstruction of large maxillary defects after tumor-resection. , 1973, Journal of maxillofacial surgery.

[22]  A Wagner,et al.  Image-guided surgery. , 1996, International journal of oral and maxillofacial surgery.

[23]  D. Riediger Restoration of Masticatory Function by Microsurgically Revascularized Iliac Crest Bone Grafts Using Enosseous Implants , 1988, Plastic and reconstructive surgery.

[24]  H Bergmann,et al.  In-vitro assessment of a registration protocol for image guided implant dentistry. , 2001, Clinical oral implants research.

[25]  A Wagner,et al.  [Computer-assisted intraoperative visualization of dental implants. Augmented reality in medicine]. , 1995, Der Radiologe.

[26]  J N Kent,et al.  Hemimaxillectomy prosthesis stabilization with hydroxylapatite coated implants: a case report. , 1987, The International journal of oral & maxillofacial implants.

[27]  E. Roumanas,et al.  Clinical evaluation of implants retaining edentulous maxillary obturator prostheses. , 1997, The Journal of prosthetic dentistry.

[28]  J L Coudert,et al.  Computer-assisted dental implant surgery using computed tomography. , 1995, Journal of image guided surgery.

[29]  J Beumer,et al.  Restoration of oral function after maxillectomy with osseous integrated implant retained maxillary obturators. , 1994, American journal of surgery.

[30]  H Bergmann,et al.  Systematic distortions in magnetic position digitizers. , 1998, Medical physics.