Thermal cycling can extend tool life in orthopaedic operating rooms

Thermal cycling is a temperature modulation process developed to improve the performance, durability and longevity of materials. This process has been successfully utilized in the automotive, aeronautic and manufacturing industries. Surgical cutting tools undergo cyclical loading and generally fail by dulling, suggesting that thermal cycling may improve their performance and longevity. Ten 2.5 mm orthopaedic drill bits were randomized, with five undergoing thermal cycling within their sterile packaging and five serving as untreated controls. Using a servohydraulic testing machine, 100 drilling cycles were performed with each drill bit into the diaphyseal region of bovine femurs. After every 25 cycles, data was collected by performing identical drilling cycles into simulated human cortical bone material. Maximum force, maximum normalized torque and drilling work were measured, and a scanning electron microscope was used to measure outer corner wear. After 100 drilling cycles, the maximum drilling force, maximum normalized torque, drilling work and microscopic outer corner wear were all significantly lower for the treated drill bits (p < 0.05). Thermal cycling has the potential to decrease operating room costs and thermal necrosis associated with dull cutting tools. Application of this technology may also be relevant to surgical cutting tools such as saw blades, burrs and reamers. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:539–543, 2016.

[1]  William Robert Walsh,et al.  Drilling of Bone: Practicality, Limitations and Complications Associated with Surgical Drill-Bits , 2011 .

[2]  Todd D. Jaeblon,et al.  The Effect of Drill Bit, Pin, and Wire Tip Design on Drilling , 2011, The Journal of the American Academy of Orthopaedic Surgeons.

[3]  William R Walsh,et al.  A comparison of the thermal properties of 2- and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model. , 2010, Clinical biomechanics.

[4]  K Darvish,et al.  The effect of tip geometry on the mechanical performance of unused and reprocessed orthopaedic drill bits , 2009, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  M T Rondina,et al.  The effects of drilling force on cortical temperatures and their duration: an in vitro study. , 2000, Medical engineering & physics.

[6]  P. Lachenbruch Statistical Power Analysis for the Behavioral Sciences (2nd ed.) , 1989 .

[7]  J A Albright,et al.  Surgical drilling: design and performance of an improved drill. , 1982, Journal of biomechanical engineering.

[8]  L. S. Matthews,et al.  Temperatures measured in human cortical bone when drilling. , 1972, The Journal of bone and joint surgery. American volume.

[9]  P. Lacki,et al.  Wear investigations of tools used in bone surgery , 2007 .

[10]  T Albrektsson,et al.  Assessment of bone viability after heat trauma. A histological, histochemical and vital microscopic study in the rabbit. , 1984, Scandinavian journal of plastic and reconstructive surgery.