Digital analysis and sorting of fluorescence lifetime by flow cytometry

Frequency‐domain flow cytometry techniques are combined with modifications to the digital signal‐processing capabilities of the open reconfigurable cytometric acquisition system (ORCAS) to analyze fluorescence decay lifetimes and control sorting. Real‐time fluorescence lifetime analysis is accomplished by rapidly digitizing correlated, radiofrequency (RF)‐modulated detector signals, implementing Fourier analysis programming with ORCAS' digital signal processor (DSP) and converting the processed data into standard cytometric list mode data. To systematically test the capabilities of the ORCAS 50 MS/sec analog‐to‐digital converter (ADC) and our DSP programming, an error analysis was performed using simulated light scatter and fluorescence waveforms (0.5–25 ns simulated lifetime), pulse widths ranging from 2 to 15 μs, and modulation frequencies from 2.5 to 16.667 MHz. The standard deviations of digitally acquired lifetime values ranged from 0.112 to >2 ns, corresponding to errors in actual phase shifts from 0.0142° to 1.6°. The lowest coefficients of variation (<1%) were found for 10‐MHz modulated waveforms having pulse widths of 6 μs and simulated lifetimes of 4 ns. Direct comparison of the digital analysis system to a previous analog phase‐sensitive flow cytometer demonstrated similar precision and accuracy on measurements of a range of fluorescent microspheres, unstained cells, and cells stained with three common fluorophores. Sorting based on fluorescence lifetime was accomplished by adding analog outputs to ORCAS and interfacing with a commercial cell sorter with a RF‐modulated solid‐state laser. Two populations of fluorescent microspheres with overlapping fluorescence intensities but different lifetimes (2 and 7 ns) were separated to ∼98% purity. Overall, the digital signal acquisition and processing methods we introduce present a simple yet robust approach to phase‐sensitive measurements in flow cytometry. The ability to simply and inexpensively implement this system on a commercial flow sorter will allow both better dissemination of this technology and better exploitation of the traditionally underutilized parameter of fluorescence lifetime. Published 2010 Wiley‐Liss, Inc.

[1]  J F Keij,et al.  Flow cytometric characterization and classification of multiple dual-color fluorescent microspheres using fluorescence lifetime. , 1998, Cytometry.

[2]  J A Steinkamp,et al.  Resolution of fluorescence signals from cells labeled with fluorochromes having different lifetimes by phase-sensitive flow cytometry. , 1993, Cytometry.

[3]  J. Steinkamp,et al.  Fluorescence lifetime‐based discrimination and quantification of cellular DNA and RNA with phase‐sensitive flow cytometry , 2003, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[4]  J A Steinkamp,et al.  Apoptosis induced with different cycle-perturbing agents produces differential changes in the fluorescence lifetime of DNA-bound ethidium bromide. , 1998, Cytometry.

[5]  J. Lakowicz,et al.  Phase-resolved fluorescence lifetime measurements for flow cytometry. , 1993, Cytometry.

[6]  James P. Freyer,et al.  Microenvironmental Regulation of Proliferation in Multicellular Spheroids Is Mediated through Differential Expression of Cyclin-Dependent Kinase Inhibitors , 2004, Cancer Research.

[7]  J A Steinkamp,et al.  Differential Effects of Deuterium Oxide on the Fluorescence Lifetimes and Intensities of Dyes with Different Modes of Binding to DNA , 1997, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[8]  L. S. Cram,et al.  Simultaneous dual-frequency phase-sensitive flow cytometric measurements for rapid identification of heterogeneous fluorescence decays in fluorochrome-labeled cells and particles. , 1995, Cytometry.

[9]  J. Steinkamp,et al.  Analysis of fluorescence lifetime and quenching of FITC-conjugated antibodies on cells by phase-sensitive flow cytometry. , 1996, Cytometry.

[10]  Jimmie D. Parson,et al.  Flow cytometric time-resolved measurements by frequency heterodyning of fluorescence emission signals , 2001 .

[11]  John A. Steinkamp,et al.  Flow cytometer for resolving signals from heterogeneous fluorescence emissions and quantifying lifetime in fluorochrome-labeled cells/particles by phase-sensitive detection , 1993 .

[12]  J A Steinkamp,et al.  Time-resolved fluorescence-decay measurement and analysis on single cells by flow cytometry. , 1996, Applied optics.

[13]  J A Steinkamp,et al.  Interactions of intercalating fluorochromes with DNA analyzed by conventional and fluorescence lifetime flow cytometry utilizing deuterium oxide. , 1996, Cytometry.

[14]  Wolfgang Beisker,et al.  Fluorescence lifetime measurements in flow cytometry , 1997, Photonics West - Biomedical Optics.

[15]  J A Steinkamp,et al.  Flow cytometric fluorescence lifetime analysis of DNA-binding probes. , 1998, European journal of histochemistry : EJH.

[16]  Steven W Graves,et al.  Open, reconfigurable cytometric acquisition system: ORCAS , 2007, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[17]  John A. Steinkamp,et al.  Fluorescence intensity and lifetime measurement of free and particle-bound fluorophore in a sample stream by phase-sensitive flow cytometry , 1999 .