Comparison of AC icing flashover performances of 220 kV composite insulators with different shed configurations
暂无分享,去创建一个
Qin Hu | Jian Liang | Xingliang Jiang | Gang Qiu | Lichun Shu | Shijing Wang | Xingliang Jiang | L. Shu | Q. Hu | Shijing Wang | G. Qiu | Jian Liang
[1] Jun Zhou,et al. Flashover Performance of HVDC Iced Insulator Strings , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.
[2] Yan Wang,et al. Study on icing of energized insulators with AC service and electrical performance , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.
[3] Xingliang Jiang,et al. Effect of shed configuration on DC flashover performance of ice-covered 110 kV composite insulators , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.
[4] T. Orbeck,et al. Application of Composite Insulators to Transmission Lines Prepared by the Task Force Members of the IEEE Working Group on Nonceramic and Composite Insulators for Transmission Lines, Lightning and Insulator Subcommittee , 1983, IEEE Power Engineering Review.
[5] Sun Cai-xin. Numerical Simulation of Water Droplet Impingement on Composite Insulator Surface and Analysis of Shed Configuration , 2008 .
[6] Xingliang Jiang,et al. Equivalence of Influence of Pollution Simulating Methods on DC Flashover Stress of Ice-Covered Insulators , 2010, IEEE Transactions on Power Delivery.
[7] Xingliang Jiang,et al. Comparison of DC Pollution Flashover Performances of Various Types of Porcelain, Glass, and Composite Insulators , 2008, IEEE Transactions on Power Delivery.
[8] Caixin Sun,et al. Flashover Performance of Pre-contaminated and Ice-covered Composite Insulators to be Used in 1000 kV UHV AC Transmission Lines , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.
[9] Yan Wang,et al. Study on AC Flashover Performance and Discharge Process of Polluted and Iced IEC Standard Suspension Insulator String , 2007, IEEE Transactions on Power Delivery.
[10] Composite Insulators for Transmission lines,et al. Application of Composite Insulators to Transmission Lines , 1983, IEEE Transactions on Power Apparatus and Systems.
[11] L. Makkonen. A model of icicle growth , 1988 .
[12] Qin Hu,et al. Effects of electric field distribution on icing and flashover performance of 220 kV composite insulators , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.
[13] M. Farzaneh,et al. Role of air gaps on AC withstand voltage of an ice-covered insulator string , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.
[14] Guan Zhicheng,et al. Development of composite insulators in China , 1999, IEEE Transactions on Dielectrics and Electrical Insulation.
[15] Jianlin Hu,et al. Study on Pollution Flashover Performance of Short Samples of Composite Insulators Intended for /spl plusmn/800 kV UHV DC , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.
[16] M. Farzaneh,et al. A laboratory investigation of the flashover performance of outdoor insulators covered with ice , 1994, Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM).
[17] Jianlin Hu,et al. DC flashover performance and effect of sheds configuration on polluted and ice–covered composite insulators at low atmospheric pressure , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.
[18] M. Farzaneh,et al. Equivalent surface conductivity of ice accumulated on insulators during development of AC and DC flashovers arcs , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.
[19] L. Rolfseng,et al. Insulator icing test methods and procedures: a position paper prepared by the IEEE task force on insulator icing test methods , 2003 .
[20] Liming Wang,et al. Influence of composite insulator shed design on contamination flashover performance at high altitudes , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.
[21] M. Farzaneh,et al. AC flashover performance of insulators covered with artificial ice , 1995 .
[22] Qin Hu,et al. Effects of shed configuration on AC flashover performance of ice-covered composite long-rod insulators , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.
[23] Jianlin Hu,et al. Study of DC flashover performance of ice-covered insulators at high altitude , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.
[24] M. Farzaneh,et al. Effect of insulator diameter on AC flashover voltage of an ice-covered insulator string , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.
[25] M. Farzaneh,et al. Insulators for Icing and Polluted Environments , 2009 .
[26] Masoud Farzaneh,et al. Flashover performance of IEEE standard insulators under ice conditions , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.
[27] Qin Hu,et al. Modeling of AC flashover on ice-covered composite insulators with different shed configurations , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.
[28] Licheng Li,et al. Field and laboratory tests of insulator flashovers under conditions of light ice accumulation and contamination , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.
[29] Qin Hu,et al. AC pollution flashover circuit model for composite insulator based on multiple arcs series , 2011 .
[30] Yi Hu,et al. Icing flashover characteristics and discharge process of 500 kV AC transmission line suspension insulator strings , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.