Comparison of AC icing flashover performances of 220 kV composite insulators with different shed configurations

The shed configuration has obvious effects on the flow field characteristics and electric field distributions around composite insulators, and then impacts their icing flashover performance. In this study, the AC flashover comparative tests for 12 types of 220 kV composite insulators with different shed configurations under non-energized and energized ice accumulation conditions are conducted in the artificial climate chamber. The influences of shed configuration on icing flashover voltages and flashover arc paths are analyzed. Results indicate that with the increase of the icing stress, both the flashover arc path and the ratio of the air gap arc gradually decrease. These variations lead the icing flashover voltage to gradually decrease and then approach to saturation. For ice-covered composite insulators with different shed configurations, the ratios of the air gap arc to the total flashover arc are different due to the differences of their shed spacings, icicle lengths, differences of shed diameters, (extra) large shed diameters. These result in the differences of icing flashover voltages and their characteristic exponent c describing the influence of ice thickness. Besides, for insulators iced under energized condition, their icing flashover voltages and flashover arc paths are different from that under non-energized condition. Hence, the energized icing test, which is also the only normative reference of icing test proposed by the IEEE standard, should be carried out to optimize the shed configuration of composite insulators used in ice areas.

[1]  Jun Zhou,et al.  Flashover Performance of HVDC Iced Insulator Strings , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[2]  Yan Wang,et al.  Study on icing of energized insulators with AC service and electrical performance , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.

[3]  Xingliang Jiang,et al.  Effect of shed configuration on DC flashover performance of ice-covered 110 kV composite insulators , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[4]  T. Orbeck,et al.  Application of Composite Insulators to Transmission Lines Prepared by the Task Force Members of the IEEE Working Group on Nonceramic and Composite Insulators for Transmission Lines, Lightning and Insulator Subcommittee , 1983, IEEE Power Engineering Review.

[5]  Sun Cai-xin Numerical Simulation of Water Droplet Impingement on Composite Insulator Surface and Analysis of Shed Configuration , 2008 .

[6]  Xingliang Jiang,et al.  Equivalence of Influence of Pollution Simulating Methods on DC Flashover Stress of Ice-Covered Insulators , 2010, IEEE Transactions on Power Delivery.

[7]  Xingliang Jiang,et al.  Comparison of DC Pollution Flashover Performances of Various Types of Porcelain, Glass, and Composite Insulators , 2008, IEEE Transactions on Power Delivery.

[8]  Caixin Sun,et al.  Flashover Performance of Pre-contaminated and Ice-covered Composite Insulators to be Used in 1000 kV UHV AC Transmission Lines , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[9]  Yan Wang,et al.  Study on AC Flashover Performance and Discharge Process of Polluted and Iced IEC Standard Suspension Insulator String , 2007, IEEE Transactions on Power Delivery.

[10]  Composite Insulators for Transmission lines,et al.  Application of Composite Insulators to Transmission Lines , 1983, IEEE Transactions on Power Apparatus and Systems.

[11]  L. Makkonen A model of icicle growth , 1988 .

[12]  Qin Hu,et al.  Effects of electric field distribution on icing and flashover performance of 220 kV composite insulators , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[13]  M. Farzaneh,et al.  Role of air gaps on AC withstand voltage of an ice-covered insulator string , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  Guan Zhicheng,et al.  Development of composite insulators in China , 1999, IEEE Transactions on Dielectrics and Electrical Insulation.

[15]  Jianlin Hu,et al.  Study on Pollution Flashover Performance of Short Samples of Composite Insulators Intended for /spl plusmn/800 kV UHV DC , 2007, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  M. Farzaneh,et al.  A laboratory investigation of the flashover performance of outdoor insulators covered with ice , 1994, Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM).

[17]  Jianlin Hu,et al.  DC flashover performance and effect of sheds configuration on polluted and ice–covered composite insulators at low atmospheric pressure , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  M. Farzaneh,et al.  Equivalent surface conductivity of ice accumulated on insulators during development of AC and DC flashovers arcs , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  L. Rolfseng,et al.  Insulator icing test methods and procedures: a position paper prepared by the IEEE task force on insulator icing test methods , 2003 .

[20]  Liming Wang,et al.  Influence of composite insulator shed design on contamination flashover performance at high altitudes , 2011, IEEE Transactions on Dielectrics and Electrical Insulation.

[21]  M. Farzaneh,et al.  AC flashover performance of insulators covered with artificial ice , 1995 .

[22]  Qin Hu,et al.  Effects of shed configuration on AC flashover performance of ice-covered composite long-rod insulators , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[23]  Jianlin Hu,et al.  Study of DC flashover performance of ice-covered insulators at high altitude , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[24]  M. Farzaneh,et al.  Effect of insulator diameter on AC flashover voltage of an ice-covered insulator string , 2006, IEEE Transactions on Dielectrics and Electrical Insulation.

[25]  M. Farzaneh,et al.  Insulators for Icing and Polluted Environments , 2009 .

[26]  Masoud Farzaneh,et al.  Flashover performance of IEEE standard insulators under ice conditions , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.

[27]  Qin Hu,et al.  Modeling of AC flashover on ice-covered composite insulators with different shed configurations , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[28]  Licheng Li,et al.  Field and laboratory tests of insulator flashovers under conditions of light ice accumulation and contamination , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[29]  Qin Hu,et al.  AC pollution flashover circuit model for composite insulator based on multiple arcs series , 2011 .

[30]  Yi Hu,et al.  Icing flashover characteristics and discharge process of 500 kV AC transmission line suspension insulator strings , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.