Versatile Stimulation Back-End With Programmable Exponential Current Pulse Shapes for a Retinal Visual Prosthesis.

This paper reports on the design, implementation, and test of a stimulation back-end, for an implantable retinal prosthesis. In addition to traditional rectangular pulse shapes, the circuit features biphasic stimulation pulses with both rising and falling exponential shapes, whose time constants are digitally programmable. A class-B second generation current conveyor is used as a wide-swing, high-output-resistance stimulation current driver, delivering stimulation current pulses of up to ±96 μA to the target tissue. Duration of the generated current pulses is programmable within the range of 100 μs to 3 ms. Current-mode digital-to-analog converters (DACs) are used to program the amplitudes of the stimulation pulses. Fabricated using the IBM 130 nm process, the circuit consumes 1.5×1.5 mm2 of silicon area. According to the measurements, the DACs exhibit DNL and INL of 0.23 LSB and 0.364 LSB, respectively. Experimental results indicate that the stimuli generator meets expected requirements when connected to electrode-tissue impedance of as high as 25 k Ω. Maximum power consumption of the proposed design is 3.4 mW when delivering biphasic rectangular pulses to the target load. A charge pump block is in charge of the upconversion of the standard 1.2-V supply voltage to ±3.3V.

[1]  Manfred Morari,et al.  Energy-optimal electrical excitation of nerve fibers , 2005, IEEE Transactions on Biomedical Engineering.

[2]  Xinyu Chai,et al.  C-Sight Visual Prostheses for the Blind , 2008, IEEE Engineering in Medicine and Biology Magazine.

[3]  Alfred Stett,et al.  Subretinal electronic chips allow blind patients to read letters and combine them to words , 2010, Proceedings of the Royal Society B: Biological Sciences.

[4]  Joseph F. Rizzo,et al.  A Hermetic Wireless Subretinal Neurostimulator for Vision Prostheses , 2011, IEEE Transactions on Biomedical Engineering.

[5]  M. Ortmanns,et al.  A 232-Channel Epiretinal Stimulator ASIC , 2007, IEEE Journal of Solid-State Circuits.

[6]  Khalil Najafi,et al.  Extremely-Wide-Range Supply-Independent CMOS Voltage References for Telemetry-Powering Applications , 2006 .

[7]  Hyoungho Ko,et al.  A 16-channel neural stimulator with DAC sharing scheme for visual prostheses , 2013, 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013).

[8]  S.K. Kelly,et al.  A power-efficient voltage-based neural tissue stimulator with energy recovery , 2004, 2004 IEEE International Solid-State Circuits Conference (IEEE Cat. No.04CH37519).

[9]  Mohamad Sawan,et al.  Capacitive-data links, energy-efficient and high-voltage compliant visual intracortical microstimulation system , 2013, 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013).

[10]  Mohammad Hossein Maghami,et al.  Visual Prostheses: The Enabling Technology to Give Sight to the Blind , 2014, Journal of ophthalmic & vision research.

[11]  Warren M Grill,et al.  Energy-efficient waveform shapes for neural stimulation revealed with a genetic algorithm , 2010, Journal of neural engineering.

[12]  Kenneth C. Smith,et al.  The current conveyor—A new circuit building block , 1968 .

[13]  Giuseppe Ferri,et al.  Low-Voltage Low-Power CMOS Current Conveyors , 2003 .

[14]  James D. Weiland,et al.  Visual Prosthesis , 2008, Proceedings of the IEEE.

[15]  Amir M. Sodagar,et al.  Biphasic, energy-efficient, current-controlled stimulation back-end for retinal visual prosthesis , 2014, 2014 IEEE International Symposium on Circuits and Systems (ISCAS).

[16]  P. Walter,et al.  Evoked cortical potentials after electrical stimulation of the inner retina in rabbits , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.

[17]  Maysam Ghovanloo,et al.  Switched-capacitor based implantable low-power wireless microstimulating systems , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[18]  Amir M. Sodagar,et al.  Analysis and design of a high-compliance ultra-high output resistance current mirror employing positive shunt feedback , 2015, Int. J. Circuit Theory Appl..

[19]  Y. Savaria,et al.  High voltage charge pump using standard CMOS technology , 2004, The 2nd Annual IEEE Northeast Workshop on Circuits and Systems, 2004. NEWCAS 2004..

[20]  Maysam Ghovanloo,et al.  An Experimental Study of Voltage, Current, and Charge Controlled Stimulation Front-End Circuitry , 2007, 2007 IEEE International Symposium on Circuits and Systems.

[21]  Wentai Liu,et al.  A System Verification Platform for High-Density Epiretinal Prostheses , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[22]  Linh Hoang,et al.  An Integrated 256-Channel Epiretinal Prosthesis , 2010, IEEE Journal of Solid-State Circuits.

[23]  Mohamad Sawan,et al.  Energy-efficient high-voltage compliant implantable brain-machine interfaces , 2013, 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[24]  Mohamad Sawan,et al.  Exponential Current Pulse Generation for Efficient Very High-Impedance Multisite Stimulation , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[25]  Ebrahim Ghafar-Zadeh,et al.  An image processing approach for blind mobility facilitated through visual intracortical stimulation. , 2012, Artificial organs.

[26]  Jessy D. Dorn,et al.  Interim results from the international trial of Second Sight's visual prosthesis. , 2012, Ophthalmology.

[27]  Warren M Grill,et al.  Efficiency Analysis of Waveform Shape for Electrical Excitation of Nerve Fibers , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[28]  Wentai Liu,et al.  A Fully-Integrated High-Compliance Voltage SoC for Epi-Retinal and Neural Prostheses , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[29]  S. Hafizovic,et al.  CMOS microelectrode array for bidirectional interaction with neuronal networks , 2006, IEEE Journal of Solid-State Circuits.

[30]  M. Pasotti,et al.  Power efficient charge pump in deep submicron standard CMOS technology , 2003, Proceedings of the 27th European Solid-State Circuits Conference.

[31]  Maurits Ortmanns,et al.  A Neural Stimulator Frontend With High-Voltage Compliance and Programmable Pulse Shape for Epiretinal Implants , 2012, IEEE Journal of Solid-State Circuits.

[32]  Mohamad Sawan,et al.  Low-power high-voltage charge pumps for implantable microstimulators , 2012, 2012 IEEE International Symposium on Circuits and Systems.

[33]  Wouter A. Serdijn,et al.  Biphasic stimulator circuit for a wide range of electrode-tissue impedance dedicated to cochlear implants , 2012, 2012 IEEE International Symposium on Circuits and Systems.

[34]  Karim Abdelhalim,et al.  128-channel fully differential digital neural recording and stimulation interface , 2009, 2009 IEEE International Symposium on Circuits and Systems.

[35]  G. Ferri,et al.  A low-voltage CMOS 1-Hz low-pass filter , 1999, ICECS'99. Proceedings of ICECS '99. 6th IEEE International Conference on Electronics, Circuits and Systems (Cat. No.99EX357).