Polymer immobilized enzyme optrodes for the detection of penicillin.

The preparation and performance of two enzyme-based fiber-optic sensors (optrodes) capable of detecting penicillin are described. Each sensor consists of a polymer membrane that is covalently attached to the tip of a glass optical fiber. The membrane contains the enzyme penicillinase and a pH-sensitive fluorescent dye. A signal is produced when the enzyme catalyzes the cleavage of the ..beta..-lactam ring of penicillin to produce penicilloic acid and, consequently, a pH change in the microenvironment of the membrane. The sensors differ in the way the polymer membrane is constructed and in the type of pH indicator dye used. Both optrodes exhibit response times (40-60 s) significantly lower than those of the corresponding enzyme electrodes (2 min). Each gives a linear response over the concentration range of 0.00025 to 0.01 M penicillin G, when measured in a 0.005 M phosphate buffer. The data indicate that these immobilization strategies produce similar results and may be considered complementary alternatives in future enzyme optrode applications.

[1]  J. Hou,et al.  Measurement of beta-lactamase activity and rate of inactivation of penicillins by a pH-stat alkalimetric titration method. , 1972, Journal of pharmaceutical sciences.

[2]  N. Opitz,et al.  Opticl fluorescence sensors for continuous measurement of chemical concentrations in biological systems , 1983 .

[3]  Otto S. Wolfbeis,et al.  Fluorescence optical sensors in analytical chemistry , 1985 .

[4]  David R. Walt,et al.  Polymer Modification of Fiber Optic Chemical Sensors as a Method of Enhancing Fluorescence Signal for pH Measurement , 1986 .

[5]  J. Ruzicka,et al.  Enzymatic determination of urea in serum based on pH measurement with the flow injection method. , 1979, Analytical chemistry.

[6]  Klaus Mosbach,et al.  An enzyme electrode for measurement of penicillin in fermentation broth: A step toward the application of enzyme electrodes in fermentation control , 1978 .

[7]  B Danielsson,et al.  Enzyme electrode and thermistor probes for determination of alcohols with alcohol oxidase. , 1983, Analytical chemistry.

[8]  W. C. White,et al.  Lysine specific enzyme electrode for determination of lysine in grains and foodstuffs. , 1978, Analytical chemistry.

[9]  M A Arnold,et al.  Enzyme-based fiber optic sensor. , 1985, Analytical chemistry.

[10]  A. Schleifer,et al.  Improved penicillin selective enzyme electrode. , 1974, Analytical chemistry.

[11]  G. Hicks,et al.  The preparation and characterization of lyophilized polyacrylamide enzyme gels for chemical analysis. , 1966, Analytical chemistry.

[12]  R Tor,et al.  New enzyme membrane for enzyme electrodes. , 1986, Analytical chemistry.