Dielectric spectroscopy for diagnosis of water tree deterioration in XLPE cables

An HV dielectric spectroscopy system has been developed for diagnostics of water tree deteriorated extruded medium voltage cables. The technique is based on the measurement of nonlinear dielectric response in the frequency domain. Today's commercially available systems are capable of resolving low loss and small variations of permittivity as a function of frequency and voltage. Experience from more than 200 field measurements was combined with laboratory investigations. Small samples were used in an accelerated aging test to elucidate the correlation between water tree growth and dielectric response. Furthermore, field aged cables were investigated in the laboratory. It has been shown that the dielectric response of water tree deteriorated crosslinked polyethylene (XLPE) cables can be recognized and classified into different types of responses related to the aging status and breakdown strength. The influence of termination and artifacts such as surface currents was investigated. The measurement method enables us to separate the response of the cable from the influence of accessories. Finally, two different field studies of the implementation of the diagnostic method are presented. The field studies show that the fault rate decreased significantly when replacement strategy was based on the diagnostic criteria formulated.

[1]  E. So,et al.  Diagnostic measurements of high voltage insulation using current comparator technology , 1994, Proceedings of 1994 IEEE International Symposium on Electrical Insulation.

[2]  P. Werelius,et al.  Diagnosis of medium voltage XLPE cables by high voltage dielectric spectroscopy , 1998, ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132).

[3]  A. Jonscher Dielectric relaxation in solids , 1983 .

[4]  P. B. Larsen,et al.  Service experience for XLPE cables installed in Norway - from graphite painted insulation screens to axially and radially water tight cable constructions , 1997 .

[5]  D Hayward,et al.  Low-frequency dielectric measurements (10-4 to 6 × 104 Hz): a new computer-controlled method , 1984 .

[6]  U. Gafvert,et al.  High voltage dielectric frequency response measurements on polyethylene samples during water tree ageing , 1995, Proceedings of 1995 IEEE 5th International Conference on Conduction and Breakdown in Solid Dielectrics.

[7]  M. Kosaki,et al.  New approach to diagnostic method of water trees , 1990, IEEE International Symposium on Electrical Insulation.

[8]  Takao Miyashita,et al.  Deterioration of Water-Immersed Polyethylene-Coated Wire by Treeing , 1971, IEEE Transactions on Electrical Insulation.

[9]  Björn Holmgren Dielectric response, breakdown strength and water tree content of medium voltage XLPE cables , 1997 .

[10]  H. Faremo,et al.  Understanding water treeing mechanisms in the development of diagnostic test methods , 1998 .

[11]  E. So,et al.  Measurement of the harmonic distortion of the insulation loss current as a diagnostic tool for high voltage cable insulation , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[12]  A. K. Jonscher,et al.  Universal relaxation law : a sequel to Dielectric relaxation in solids , 1996 .

[13]  E. F. Steennis,et al.  Water treeing in polyethylene cables , 1990 .

[14]  R. Eriksson,et al.  Frequency domain response of medium voltage XLPE cable terminations and its influence on cable diagnostics , 2000, Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075).

[15]  A. Bulinski,et al.  Water treeing in binary linear polyethylene blends: the mechanical aspect , 1994 .