Recent Advances in High-Birefringence Fiber Loop Mirror Sensors

Recent advances in devices and applications of high-birefringence fiber loop mirror sensors are addressed. In optical sensing, these devices may be used as strain and temperature sensors, in a separate or in a simultaneous measurement. Other described applications include: refractive index measurement, optical filters for interrogate gratings structures and chemical etching control. The paper analyses and compares different types of high-birefringence fiber loop mirror sensors using conventional and microstructured optical fibers. Some configurations are presented for simultaneous measurement of physical parameters when combined with others optical devices, for example with a long period grating.

[1]  Xinhuan Feng,et al.  High-birefringence fiber loop mirrors and their applications as sensors. , 2005, Applied optics.

[2]  Brian Culshaw,et al.  The optical fibre Sagnac interferometer: an overview of its principles and applications , 2005 .

[3]  K. Okamoto,et al.  Polarization-maintaining fibers and their applications , 1986 .

[4]  Dong Bo,et al.  Liquid-level sensor with a high-birefringence-fiber loop mirror. , 2006, Applied optics.

[5]  Seunghwan Chung,et al.  Phase response design of a polarization-maintaining fiber loop mirror for dispersion compensation , 2003, IEEE Photonics Technology Letters.

[6]  Orlando Frazão,et al.  Fibre Bragg grating interrogation based on high‐birefringence fibre loop mirror for strain temperature discrimination , 2006 .

[7]  D. Richardson,et al.  Nonlinearity in holey optical fibers: measurement and future opportunities. , 1999, Optics letters.

[8]  Xiufeng Yang,et al.  FBG sensor interrogation with high temperature insensitivity by using a HiBi-PCF Sagnac loop filter , 2005 .

[9]  J.U. Kang,et al.  Polarization-independent "figure-eight" birefringent Sagnac variable comb-filter/attenuator , 2004, IEEE Photonics Technology Letters.

[10]  Do-Hyun Kim,et al.  Sagnac loop interferometer based on polarization maintaining photonic crystal fiber with reduced temperature sensitivity. , 2004, Optics express.

[11]  K.S. Chiang,et al.  Gain flattening of an erbium-doped fiber amplifier using a high-birefringence fiber loop mirror , 2001, IEEE Photonics Technology Letters.

[12]  Xiaoyi Dong,et al.  Study on an optical filter constituted by concatenated Hi-Bi fiber loop mirrors , 2004 .

[13]  R. Buczyński Photonic Crystal Fibers , 2004 .

[14]  J.L. Santos,et al.  Strain and Temperature Discrimination Using Concatenated High-Birefringence Fiber Loop Mirrors , 2007, IEEE Photonics Technology Letters.

[15]  Kin Seng Chiang,et al.  Multiwavelength erbium-doped fibre laser based on a high-birefringence fibre loop mirror , 2000 .

[16]  O. Frazao,et al.  Temperature-Independent Strain Sensor Based on a Hi-Bi Photonic Crystal Fiber Loop Mirror , 2007, IEEE Sensors Journal.

[17]  Seunghwan Chung,et al.  A fiber Bragg grating sensor demodulation technique using a polarization maintaining fiber loop mirror , 2001, IEEE Photonics Technology Letters.

[18]  Hwa-Yaw Tam,et al.  Temperature-insensitive strain sensor with polarization-maintaining photonic crystal fiber based Sagnac interferometer , 2007 .

[19]  Orlando Frazão,et al.  Fiber Bragg grating sensing system for simultaneous measurement of salinity and temperature , 2004 .

[20]  J.L. Santos,et al.  Simultaneous Measurement for Strain and Temperature Based on a Long-Period Grating Combined With a High-Birefringence Fiber Loop Mirror , 2006, IEEE Photonics Technology Letters.

[21]  M.S. Demokan,et al.  Temperature-insensitive Interferometer using a highly birefringent photonic Crystal fiber loop mirror , 2004, IEEE Photonics Technology Letters.

[22]  R O Claus,et al.  Polarization-independent all-fiber wavelength-division multiplexer based on a Sagnac interferometer. , 1995, Optics letters.

[23]  Orlando Frazão,et al.  DESIGN NOTE: Birefringence monitoring of a Hi-Bi fibre under chemical etching through a fibre loop mirror , 2007 .

[24]  D. B. Mortimore,et al.  Fiber loop reflectors , 1988 .

[25]  A. S. Holmes-Smith,et al.  A frequency-modulated continuous wave birefringent fibre-optic strain sensor based on a Sagnac ring configuration , 1999 .

[26]  David J. Richardson,et al.  Sensing with microstructured optical fibres , 2001 .

[27]  J. Lit,et al.  Temperature and strain sensitivity measurements of high-birefringent polarization-maintaining fibers. , 1993, Applied optics.

[28]  L. A. Zenteno,et al.  Fiber Sagnac interferometer temperature sensor , 1997 .

[29]  Orlando Frazão,et al.  Temperature independent strain/load sensor using a highly birefringent photonic crystal fibre loop mirror , 2007, European Workshop on Optical Fibre Sensors.

[30]  S. James,et al.  Optical fibre long-period grating sensors: characteristics and application , 2003 .

[31]  P. Russell Photonic Crystal Fibers , 2003, Science.

[32]  V. Bhatia Applications of long-period gratings to single and multi-parameter sensing. , 1999, Optics express.