Energy and exergy analysis of zeotropic mixture R290/R600a vapor-compression refrigeration cycle with separation condensation

This paper proposes a modified vapor-compression refrigeration cycle (MVRC) system operating with the zeotropic mixture R290/R600a for domestic refrigerator-freezers. In the MVRC system, a phase separator is introduced to enhance the overall system performance. A theoretical energy and exergy analysis on the performance of the MVRC is carried out by using the developed mathematical model, and then compared with that of the traditional vapor-compression refrigeration cycle (TVRC) operating with the refrigerant R600a and the zeotropic mixture R290/R600a, respectively. According to the simulation results of these two cycles, the MVRC can give the most excellent performances in the COP (coefficient of performance), the volumetric refrigeration capacity, the total exergy destruction and the exergetic efficiency under the same given operating conditions. Therefore, the performance characteristics of the MVRC may show its promise in domestic refrigerator-freezer applications.

[1]  Hyun Joon Chung,et al.  Performance optimization of dual-loop cycles using R-600a and hydrocarbon mixtures designed for a domestic refrigerator-freezer , 2012 .

[2]  R. Saravanakumar,et al.  Exergy analysis of a domestic refrigerator using eco-friendly R290/R600a refrigerant mixture as an alternative to R134a , 2013, Journal of Thermal Analysis and Calorimetry.

[3]  J. U. Ahamed,et al.  A review on exergy analysis of vapor compression refrigeration system , 2011 .

[4]  Hyun Joon Chung,et al.  Performance optimization of a Lorenz–Meutzner cycle charged with hydrocarbon mixtures for a domestic refrigerator-freezer , 2012 .

[5]  J. Corberán,et al.  Review of standards for the use of hydrocarbon refrigerants in A/C, heat pump and refrigeration equipment ☆ , 2008 .

[6]  Mark O. McLinden,et al.  NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures-REFPROP , 1998 .

[7]  Dong Yeon Lee,et al.  Performance characteristics of a small-capacity directly cooled refrigerator using R290/R600a (55/45) , 2008 .

[8]  Mohammad Sadegh Hatamipour,et al.  Exergy analysis and optimization of R600a as a replacement of R134a in a domestic refrigerator system , 2013 .

[9]  Bukola Olalekan Bolaji,et al.  Ozone depletion and global warming: Case for the use of natural refrigerant – a review , 2013 .

[10]  S. Jayaraj,et al.  Experimental investigation of R290/R600a mixture as an alternative to R134a in a domestic refrigerator , 2009 .

[11]  V. Selladurai,et al.  Experimental analysis of a new refrigerant mixture as drop-in replacement for CFC12 and HFC134a , 2008 .

[12]  Chin-Chia Su,et al.  Experimental studies of isobutane (R600a) as the refrigerant in domestic refrigeration system , 2002 .

[13]  G. K. Awari,et al.  Alternative refrigerants in vapour compression refrigeration cycle for sustainable environment: a review of recent research , 2013, International Journal of Environmental Science and Technology.

[14]  S. C. Kaushik,et al.  Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507A , 2008 .

[15]  Mehdi Rasti,et al.  Enhancement of domestic refrigerator’s energy efficiency index using a hydrocarbon mixture refrigerant , 2012 .

[16]  B. Palm Hydrocarbons as refrigerants in small heat pump and refrigeration systems – A review , 2008 .

[17]  T. Teng,et al.  Retrofit assessment of refrigerator using hydrocarbon refrigerants , 2014 .

[18]  Rémi Revellin,et al.  Exergy analysis of R413A as replacement of R12 in a domestic refrigeration system , 2010 .

[19]  M. Elakdhar,et al.  Analysis of a Compression/Ejection Cycle for Domestic Refrigeration , 2007 .

[20]  A. S. Dalkılıç,et al.  A performance comparison of vapour-compression refrigeration system using various alternative refrigerants , 2010 .

[21]  E. Granryd Hydrocarbons as refrigerants — an overview , 2001 .

[22]  P. Somasundaram,et al.  Exergy and energy analysis of three stage auto refrigerating cascade system using Zeotropic mixture for sustainable development , 2014 .

[23]  Aj Gigiel Safety testing of domestic refrigerators using flammable refrigerants , 2004 .

[24]  Mehdi Rasti,et al.  Energy efficiency enhancement of a domestic refrigerator using R436A and R600a as alternative refrigerants to R134a , 2013 .