Dose convolution filter: incorporating spatial dose information into tissue response modeling.

PURPOSE A model is introduced to integrate biological factors such as cell migration and bystander effects into physical dose distributions, and to incorporate spatial dose information in plan analysis and optimization. METHODS The model consists of a dose convolution filter (DCF) with single parameter sigma. Tissue response is calculated by an existing NTCP model with DCF-applied dose distribution as input. The authors determined sigma of rat spinal cord from published data. The authors also simulated the GRID technique, in which an open field is collimated into many pencil beams. RESULTS After applying the DCF, the NTCP model successfully fits the rat spinal cord data with a predicted value of sigma = 2.6 +/- 0.5 mm, consistent with 2 mm migration distances of remyelinating cells. Moreover, it enables the appropriate prediction of a high relative seriality for spinal cord. The model also predicts the sparing of normal tissues by the GRID technique when the size of each pencil beam becomes comparable to sigma. CONCLUSIONS The DCF model incorporates spatial dose information and offers an improved way to estimate tissue response from complex radiotherapy dose distributions. It does not alter the prediction of tissue response in large homogenous fields, but successfully predicts increased tissue tolerance in small or highly nonuniform fields.

[1]  Tilman Butz,et al.  Radiation-Induced Bystander Effects , 2003, Strahlentherapie und Onkologie.

[2]  A Brahme,et al.  Tumour and normal tissue responses to fractionated non-uniform dose delivery. , 1992, International journal of radiation biology.

[3]  A. Niemierko,et al.  Modelling the dose-volume response of the spinal cord, based on the idea of damage to contiguous functional subunits. , 2001, International journal of radiation biology.

[4]  R. Franklin,et al.  Local recruitment of remyelinating cells in the repair of demyelination in the central nervous system , 1997, Journal of neuroscience research.

[5]  G J Kutcher,et al.  Probability of radiation-induced complications for normal tissues with parallel architecture subject to non-uniform irradiation. , 1993, Medical physics.

[6]  Radiation dose-tumor control assays for irradiation through a sieve. , 1968, The American journal of roentgenology, radium therapy, and nuclear medicine.

[7]  Mageras,et al.  Control, Correction, and Modeling of Setup Errors and Organ Motion. , 1995, Seminars in radiation oncology.

[8]  Peter van Luijk,et al.  Unexpected changes of rat cervical spinal cord tolerance caused by inhomogeneous dose distributions. , 2003, International journal of radiation oncology, biology, physics.

[9]  J. Kummermehr Tumour Stem Cells&The Evidence and the Ambiguity , 2001, Acta oncologica.

[10]  Peter van Luijk,et al.  Dose-volume effects in the rat cervical spinal cord after proton irradiation. , 2002, International journal of radiation oncology, biology, physics.

[11]  A. Niemierko,et al.  Modeling of normal tissue response to radiation: the critical volume model. , 1993, International journal of radiation oncology, biology, physics.

[12]  P. van Luijk,et al.  Data on dose-volume effects in the rat spinal cord do not support existing NTCP models. , 2005, International journal of radiation oncology, biology, physics.

[13]  P. van Luijk,et al.  Estimation of parameters of dose-volume models and their confidence limits. , 2003, Physics in medicine and biology.

[14]  Steve B. Jiang,et al.  Effects of motion on the total dose distribution. , 2004, Seminars in radiation oncology.

[15]  Radhe Mohan,et al.  Cluster models of dose-volume effects. , 2004, International journal of radiation oncology, biology, physics.

[16]  Andrew R. Snyder Review of radiation-induced bystander effects , 2004, Human & experimental toxicology.

[17]  A B Wolbarst,et al.  Optimization of radiation therapy, III: A method of assessing complication probabilities from dose-volume histograms. , 1987, International journal of radiation oncology, biology, physics.

[18]  Anders Brahme,et al.  The dose–response relation for rat spinal cord paralysis analyzed in terms of the effective size of the functional subunit , 2008, Physics in medicine and biology.

[19]  M. Mohiuddin,et al.  Palliative treatment of advanced cancer using multiple nonconfluent pencil beam radiation: A pilot study , 1990, Cancer.

[20]  J. Lyman Complication Probability as Assessed from Dose-Volume Histograms , 1985 .