An Adaptive MMC Synchronous Stability Control Method Based on Local PMU measurements

Reducing the current is a common method to ensure the synchronous stability of a modular multilevel converter (MMC) when there is a short-circuit fault at its AC side. However, the uncertainty of the fault location of the AC system leads to a significant difference in the maximum allowable stable operating current during the fault. This paper proposes an adaptive MMC fault-current control method using local phasor measurement unit (PMU) measurements. Based on the estimated Thevenin equivalent (TE) parameters of the system, the current can be directly calculated to ensure the maximum output power of the MMC during the fault. This control method does not rely on off-line simulation and adapts itself to various fault conditions. The effective measurements are firstly selected by the voltage threshold and parameter constraints, which allow us to handle the error due to the change on the system-side. The proposed TE estimation method can fast track the change of the system impedance without depending on the initial value and can deal with the TE potential changes after a large disturbance. The simulation shows that the TE estimation can accurately track the TE parameters after the fault, and the current control instruction during an MMC fault can ensure the maximum output power of the MMC.

[1]  Shri harsha,et al.  Voltage Source Converter Based HVDC Transmission , 2012 .

[2]  F. W. Fuchs,et al.  Online grid impedance estimation for the control of grid connected converters in inductive-resistive distributed power-networks using extended kalman-filter , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[3]  Zhihao Yun,et al.  Online Thevenin Equivalent Parameter Identification Method of Large Power Grids Using LU Factorization , 2019, IEEE Transactions on Power Systems.

[4]  V.G. Agelidis,et al.  VSC-Based HVDC Power Transmission Systems: An Overview , 2009, IEEE Transactions on Power Electronics.

[5]  K. Vu,et al.  Use of local measurements to estimate voltage-stability margin , 1997 .

[6]  Gexiang Zhang,et al.  Robust Voltage Instability Predictor , 2017, IEEE Transactions on Power Systems.

[7]  Xiongfei Wang,et al.  Design-Oriented Transient Stability Analysis of PLL-Synchronized Voltage-Source Converters , 2019, IEEE Transactions on Power Electronics.

[8]  P. Kundur,et al.  Power system stability and control , 1994 .

[9]  Lars Nordström,et al.  Real-time estimation of AC-grid short circuit capacity for HVDC control application , 2017 .

[10]  Chunyi Guo,et al.  An Improved Measure of AC System Strength for Performance Analysis of Multi-Infeed HVdc Systems Including VSC and LCC Converters , 2018, IEEE Transactions on Power Delivery.

[11]  Hongbin Sun,et al.  Real-time local voltage stability monitoring based on PMU and recursive least square method with variable forgetting factors , 2012, IEEE PES Innovative Smart Grid Technologies.

[12]  D. John Morrow,et al.  Online Thévenin Equivalent Determination Considering System Side Changes and Measurement Errors , 2015, IEEE Transactions on Power Systems.

[13]  Xiongfei Wang,et al.  An Adaptive Phase-Locked Loop for the Transient Stability Enhancement of Grid-Connected Voltage Source Converters , 2018, 2018 IEEE Energy Conversion Congress and Exposition (ECCE).

[14]  Frede Blaabjerg,et al.  An Efficient Reduced-Order Model for Studying Synchronization Stability of Grid-Following Converters during Grid Faults , 2019, 2019 20th Workshop on Control and Modeling for Power Electronics (COMPEL).