Performance evaluation of multi-storey cross-laminated timber structures under different earthquake hazard levels

The inter-storey drift limitations are meaningful reference values for structural seismic performance evaluation. This paper presents an analytical investigation into the seismic performance of multi-storey cross-laminated timber (CLT) structures to obtain the drift limitations under different earthquake hazard levels reasonably. The Pinching4 model was used to simulate the nonlinear mechanical behavior of three types of connections used in CLT structures, and a numerical model was further developed to capture the lateral load-resisting properties of CLT shear walls. Moreover, three benchmark multi-storey CLT apartment buildings were designed using the Equivalent Static Force Procedure according to National Building Code of Canada (NBCC), and simplified structural models were developed for these buildings. Depending on the results from numerous time-history dynamic analyses, the empirical cumulative distribution functions (CDFs) of the maximum inter-storey drifts were constructed for the three benchmark buildings. The probability of non-exceedance (PNE) of inter-storey drift thresholds under different earthquake hazard levels was proposed and validated. It is recommended that for low-rise CLT buildings within three stories, values of 0.30%, 0.75%, and 1.40% can be considered as the drift limitations for frequent, medium, and rare seismic hazard levels, respectively. For mid-rise or high-rise buildings without three stories, 0.25%, 0.70%, and 1.30% can be considered as drift limitations.

[1]  J. E. Portmann Waste heat in the aquatic environment , 1976 .

[2]  A. Ang,et al.  Mechanistic Seismic Damage Model for Reinforced Concrete , 1985 .

[3]  N. Null Minimum Design Loads for Buildings and Other Structures , 2003 .

[4]  Ario Ceccotti,et al.  SOFIE Project - Test results on the lateral resistance of cross-laminated wooden panels , 2006 .

[5]  Ario Ceccotti,et al.  A proposal for a standard procedure to establish the seismic behaviour factor q of timber buildings , 2010 .

[6]  Massimo Fragiacomo,et al.  Elastic and ductile design of multi-storey crosslam massive wooden buildings under seismic actions , 2011 .

[7]  John W. van de Lindt,et al.  Approximate R-Factor for Cross-Laminated Timber Walls in Multistory Buildings , 2013 .

[8]  PeiShiling,et al.  Analytical study on seismic force modification factors for cross-laminated timber buildings , 2013 .

[9]  Solomon Tesfamariam,et al.  Hysteresis behavior of bracket connection in cross-laminated-timber shear walls , 2013 .

[10]  Naohito Kawai,et al.  SOFIE project – 3D shaking table test on a seven‐storey full‐scale cross‐laminated timber building , 2013 .

[11]  M. Fragiacomo,et al.  Cyclic behavior of typical screwed connections for cross-laminated (CLT) structures , 2015, European Journal of Wood and Wood Products.

[12]  Solomon Tesfamariam,et al.  Damage Assessment of Connections Used in Cross-Laminated Timber Subject to Cyclic Loads , 2014 .

[13]  M. Fragiacomo,et al.  Behaviour of Cross-Laminated Timber Panels under Cyclic Loads , 2014 .

[14]  Ario Ceccotti,et al.  Cyclic behaviour of typical metal connectors for cross-laminated (CLT) structures , 2015 .

[15]  Ario Ceccotti,et al.  Cyclic Behavior of CLT Wall Systems: Experimental Tests and Analytical Prediction Models , 2015 .

[16]  Solomon Tesfamariam,et al.  Assessment and comparison of experimental and numerical model studies of cross-laminated timber mechanical connections under cyclic loading , 2015 .

[17]  Gianvittorio Rizzano,et al.  Seismic behavior of cross-laminated timber panel buildings equipped with traditional and innovative connectors , 2017 .