A linear laser scanner to measure cross-sectional shape and area of biological specimens during mechanical testing.

Measure of the cross-sectional area (CSA) of biological specimens is a primary concern for many biomechanical tests. Different procedures are presented in literature but besides the fact that noncontact techniques are required during mechanical testing, most of these procedures lack accuracy or speed. Moreover, they often require a precise positioning of the specimen, which is not always feasible, and do not enable the measure of the same section during tension. The objective of this study was to design a noncontact, fast, and accurate device capable of acquiring CSA of specimens mounted on a testing machine. A system based on the horizontal linear displacement of two charge-coupled device reflectance laser devices next to the specimen, one for each side, was chosen. The whole measuring block is mounted on a vertical linear guide to allow following the measured zone during sample tension (or compression). The device was validated by measuring the CSA of metallic rods machined with geometrical shapes (circular, hexagonal, semicircular, and triangular) as well as an equine superficial digital flexor tendon (SDFT) in static condition. We also performed measurements during mechanical testing of three SDFTs, obtaining the CSA variations until tendon rupture. The system was revealed to be very fast with acquisition times in the order of 0.1 s and interacquisition time of about 1.5 s. Measurements of the geometrical shapes yielded mean errors lower than 1.4% (n=20 for each shape) while the tendon CSA at rest was 90.29 ± 1.69 mm(2) (n=20). As for the tendons that underwent tension, a mean of 60 measures were performed for each test, which lasted about 2 min until rupture (at 20 mm/min), finding CSA variations linear with stress (R(2)>0.85). The proposed device was revealed to be accurate and repeatable. It is easy to assemble and operate and capable of moving to follow a defined zone on the specimen during testing. The system does not need precise centering of the sample and can perform noncontact measures during mechanical testing; therefore, it can be used to measure variations of the specimen CSA during a tension (or compression) test in order to determine, for instance, the true stress and transverse deformations.

[1]  Daniel K. Moon,et al.  The development and validation of a charge-coupled device laser reflectance system to measure the complex cross-sectional shape and area of soft tissues. , 2006, Journal of biomechanics.

[2]  Gian Marco Revel,et al.  Measurement of stress-strain and vibrational properties of tendons , 2003 .

[3]  Henry Eyring,et al.  The Mechanical Properties of Rat Tail Tendon , 1959, The Journal of general physiology.

[4]  M. Reiser,et al.  Evaluation of the cruciate ligaments by CT. , 1981, European journal of radiology.

[5]  Tetsuo Fukunaga,et al.  Calculation of muscle strength per unit cross-sectional area of human muscle by means of ultrasonic measurement , 1968, Internationale Zeitschrift für angewandte Physiologie einschließlich Arbeitsphysiologie.

[6]  N Crevier-Denoix,et al.  Correlations between mean echogenicity and material properties of normal and diseased equine superficial digital flexor tendons: an in vitro segmental approach. , 2005, Journal of biomechanics.

[7]  P. Pourcelot,et al.  Segmental variations of in vitro mechanical properties in equine superficial digital flexor tendons. , 1996, American journal of veterinary research.

[8]  P. Walker,et al.  Ligament length patterns, strength, and rotational axes of the knee joint. , 1976, Clinical orthopaedics and related research.

[9]  H. Screen,et al.  The micro-structural strain response of tendon , 2007 .

[10]  E. H. Harris,et al.  Stress-strain relationship in human cadaveric plantaris tendon: A preliminary study , 1964, Medical electronics and biological engineering.

[11]  Vanbrocklin Jd,et al.  A STUDY OF THE MECHANICAL BEHAVIOR OF TOE EXTENSOR TENDONS UNDER APPLIED STRESS. , 1965 .

[12]  J Hashemi,et al.  An alternative method of anthropometry of anterior cruciate ligament through 3-D digital image reconstruction. , 2005, Journal of biomechanics.

[13]  R Steindler,et al.  Measurements of cross-sectional area of collagen structures (knee ligaments) by means of an optical method. , 1987, Journal of biomechanics.

[14]  Subramanian Kn,et al.  Tensile strength of canine cranial cruciate ligaments. , 1971 .

[15]  A. Nachemson,et al.  Some mechanical properties of the third human lumbar interlaminar ligament (ligamentum flavum). , 1968, Journal of biomechanics.

[16]  D. Wright,et al.  A STUDY OF THE ELASTIC PROPERTIES OF PLANTAR FASCIA. , 1964, The Journal of bone and joint surgery. American volume.

[17]  C B Frank,et al.  A new method of measuring the cross-sectional area of connective tissue structures. , 1988, Journal of biomechanical engineering.

[18]  Michael Abrahams,et al.  Mechanical behaviour of tendonIn vitro , 1967, Medical and biological engineering.

[19]  S L Woo,et al.  A new method for determining cross-sectional shape and area of soft tissues. , 1988, Journal of biomechanical engineering.

[20]  S. Lu,et al.  Strain and mechanical behavior measurements of soft tissues with digital speckle method. , 2005, Journal of biomedical optics.

[21]  S L Woo,et al.  The use of a laser micrometer system to determine the cross-sectional shape and area of ligaments: a comparative study with two existing methods. , 1990, Journal of biomechanical engineering.

[22]  Alfred Eugene Cronkite,et al.  The tensile strength of human tendons , 1935 .

[23]  H. Elden THE INTERACTION OF CONNECTIVE TISSUE WITH AQUEOUS UREA. I. REVERSIBLE AND IRREVERSIBLE EFFECTS. , 1963, Biochimica et biophysica acta.

[24]  M Abrahams,et al.  Mechanical behaviour of tendon in vitro. A preliminary report. , 1967, Medical & biological engineering.

[25]  P. Webbon,et al.  The cross-sectional areas of normal equine digital flexor tendons determined ultrasonographically. , 1994, Equine veterinary journal.

[26]  Amy B. Zavatsky,et al.  Image-based non-contact method to measure cross-sectional areas and shapes of tendons and ligaments , 2008 .

[27]  L. N. Scotten,et al.  Development andin vitro assessment of a new two-leaflet replacement heart valve designed using computer-generated bubble surfaces , 2006, Medical and Biological Engineering and Computing.

[28]  Siaw Meng Chou,et al.  CROSS-SECTIONAL AREA MEASUREMENT OF SOFT TISSUES IN VITRO: A NON-CONTACT LASER SCAN METHOD , 2008 .

[29]  S L Woo,et al.  Measurement of mechanical properties of ligament substance from a bone‐ligament‐bone preparation , 1983, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[30]  Gabriel G. Pokhai,et al.  A new laser reflectance system capable of measuring changing cross-sectional area of soft tissues during tensile testing. , 2009, Journal of biomechanical engineering.

[31]  D P Pioletti,et al.  Strain rate effect on the mechanical behavior of the anterior cruciate ligament-bone complex. , 1999, Medical engineering & physics.

[32]  C. Gratz TENSILE STRENGTH AND ELASTICITY TESTS ON HUMAN FASCIA LATA , 1931 .

[33]  D G Ellis,et al.  Cross-sectional area measurements for tendon specimens: a comparison of several methods. , 1969, Journal of biomechanics.

[34]  D. Elliott,et al.  Effect of fiber orientation and strain rate on the nonlinear uniaxial tensile material properties of tendon. , 2003, Journal of biomechanical engineering.

[35]  A. Race,et al.  Cross-sectional area measurement of soft tissue. A new casting method. , 1996, Journal of biomechanics.

[36]  F Guilak,et al.  Regional material properties of the human hip joint capsule ligaments , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.