Feasibility of k-t BLAST For BOLD fMRI With a Spin-Echo Based Acquisition at 3 T and 7 T

Objectives:This study tested the feasibility of applying k-t BLAST to blood oxygen level dependent functional MRI of the brain at 3 Tesla (T) and at 7 T. Shorter echo train lengths, achieved through the application of k-t BLAST, are expected to counteract increased sensitivity to inhomogeneities in B0 at higher magnetic field strengths, especially in echo planar images, and reduce the relatively long acquisition times and high RF power deposition in spin-echo based methods. Materials and Methods:k-t BLAST was combined with displaced UFLARE at 3 T and 7 T. Temporal and spatial fidelity of k-t BLAST were investigated using a test object, in which localized variations in signal intensity mimic activation-induced signal changes. fMRI was performed using typical box-car design finger tapping. In a separate analysis full k-space data were decimated to simulate k-t BLAST acquisitions and compare results with the fully sampled data, thereby avoiding physiological and noise differences between acquisitions. Results:Activation can be detected at under-sampling factors as high as 16, whereas appropriately reconstructed data, under-sampled at factors below 8 entail insignificant loss of sensitivity and considerable reductions in acquisition times and RF power deposition. Conclusions:k-t BLAST is compatible with fMRI acquisitions and opens up possibilities including distortion-free T2*-weighted blood oxygen level dependent fMRI with displaced UFLARE at high magnetic field strengths.

[1]  L Kaufman,et al.  Inner volume MR imaging: technical concepts and their application. , 1985, Radiology.

[2]  D. Norris,et al.  Ultrafast Low‐Angle RARE: U‐FLARE , 1991, Magnetic resonance in medicine.

[3]  D. Feinberg,et al.  GRASE (Gradient‐and Spin‐Echo) imaging: A novel fast MRI technique , 1991, Magnetic resonance in medicine.

[4]  D. G. Norris,et al.  Coherence and Interference in Ultrafast RARE Experiments , 1993 .

[5]  W. Manning,et al.  Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays , 1997, Magnetic resonance in medicine.

[6]  R. Edelman,et al.  Resolution enhancement in single‐shot imaging using simultaneous acquisition of spatial harmonics (SMASH) , 1999, Magnetic resonance in medicine.

[7]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[8]  T. Niendorf On the application of susceptibility‐weighted ultra‐fast low‐angle RARE experiments in functional MR imaging , 1999, Magnetic resonance in medicine.

[9]  G. Glover,et al.  Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[10]  A. Shmuel,et al.  Imaging brain function in humans at 7 Tesla , 2001, Magnetic resonance in medicine.

[11]  F H Epstein,et al.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE) † , 2001, Magnetic resonance in medicine.

[12]  Robert A. Österbauer,et al.  Sensitivity‐encoded single‐shot spiral imaging for reduced susceptibility artifacts in BOLD fMRI , 2002, Magnetic resonance in medicine.

[13]  Peter Kellman,et al.  Application of sensitivity‐encoded echo‐planar imaging for blood oxygen level‐dependent functional brain imaging † , 2002, Magnetic resonance in medicine.

[14]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[15]  Christine Preibisch,et al.  Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI) , 2003, NeuroImage.

[16]  Peter Boesiger,et al.  k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations , 2003, Magnetic resonance in medicine.

[17]  Peter Boesiger,et al.  Accelerating cardiac cine 3D imaging using k‐t BLAST , 2004, Magnetic resonance in medicine.

[18]  Peter Boesiger,et al.  On the influence of training data quality in k‐t BLAST reconstruction , 2004, Magnetic resonance in medicine.

[19]  Peter Boesiger,et al.  Accelerating cine phase‐contrast flow measurements using k‐t BLAST and k‐t SENSE , 2005, Magnetic resonance in medicine.

[20]  Essa Yacoub,et al.  Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans , 2005, NeuroImage.

[21]  Peter van Gelderen,et al.  Improved BOLD detection in the medial temporal region using parallel imaging and voxel volume reduction , 2006, NeuroImage.

[22]  Steen Moeller,et al.  Application of parallel imaging to fMRI at 7 Tesla utilizing a high 1D reduction factor , 2006, Magnetic resonance in medicine.

[23]  P Boesiger,et al.  Influence of SENSE on image properties in high‐resolution single‐shot echo‐planar DTI , 2006, Magnetic resonance in medicine.

[24]  D. Norris Selective parity RARE imaging , 2007, Magnetic resonance in medicine.

[25]  R. Seurinck,et al.  Comparison Between Functional Magnetic Resonance Imaging at 1.5 and 3 Tesla: Effect of Increased Field Strength on 4 Paradigms Used During Presurgical Work-up , 2007, Investigative radiology.

[26]  P. Boesiger,et al.  Dynamic contrast‐enhanced myocardial perfusion MRI accelerated with k‐t sense , 2007, Magnetic resonance in medicine.

[27]  Chunlei Liu,et al.  Sliding‐window sensitivity encoding (SENSE) calibration for reducing noise in functional MRI (fMRI) , 2008, Magnetic resonance in medicine.

[28]  Peter Boesiger,et al.  Determination of peak velocity in stenotic areas: echocardiography versus k-t SENSE accelerated MR Fourier velocity encoding. , 2008, Radiology.