A Precision, Energy-Efficient, Oversampling, Noise-Shaping Differential SAR Capacitance-to-Digital Converter

This paper introduces an oversampling, noise-shaping differential successive-approximation-register capacitance-to-digital converter (CDC) architecture for interfacing capacitive sensors. The proposed energy-efficient CDC achieves high-precision capacitive resolution by employing oversampling and noise shaping. The switched-capacitor (SC) integrator is inserted between the comparator and the charge-redistribution digital-to-analog converter to implement noise shaping and to make the interface circuit insensitive to parasitic capacitances. An inverter-based operational transconductance amplifier with a common-mode feedback circuit is employed to implement the SC integrator with subthreshold biasing for low voltage and low power. The ring-oscillator-based comparator is implemented to achieve high energy efficiency. The test chip is fabricated in a 0.18-<inline-formula> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> CMOS technology. The proposed CDC experimentally achieves 150 aF absolute resolution and 12.74-ENOB with an oversampling ratio of 15 and a sampling clock of 18.51 kHz. The fabricated prototype dissipates 1.2 and 0.39 <inline-formula> <tex-math notation="LaTeX">$\mu \text{W}$ </tex-math></inline-formula> from analog and digital supplies, respectively, with an energy efficiency figure-of-merit of 187 fJ/conversion step.

[1]  Arup K. George,et al.  A 0.8 V Supply- and Temperature-Insensitive Capacitance-to-Digital Converter in 0.18- $\mu \text{m}$ CMOS , 2016, IEEE Sensors Journal.

[2]  David Blaauw,et al.  Circuits for a Cubic-Millimeter Energy-Autonomous Wireless Intraocular Pressure Monitor , 2011, IEEE Transactions on Circuits and Systems I: Regular Papers.

[3]  Gunhee Han,et al.  Low Voltage, Low Power, Inverter-Based , 2009 .

[4]  P. Bruschi,et al.  A Current-Mode, Dual Slope, Integrated Capacitance-to-Pulse Duration Converter , 2007, IEEE Journal of Solid-State Circuits.

[5]  Boby George,et al.  An Easy-to-Interface CDC With an Efficient Automatic Calibration , 2016, IEEE Transactions on Instrumentation and Measurement.

[6]  Paolo Bruschi,et al.  A Low-Power Interface for Capacitive Sensors With PWM Output and Intrinsic Low Pass Characteristic , 2013, IEEE Transactions on Circuits and Systems I: Regular Papers.

[7]  Khaled N. Salama,et al.  Insights on Capacitive Interdigitated Electrodes Coated with MOF Thin Films: Humidity and VOCs Sensing as a Case Study , 2015, Sensors.

[8]  Muhammad Arsalan,et al.  7.9 pJ/Step Energy-Efficient Multi-Slope 13-bit Capacitance-to-Digital Converter , 2014, IEEE Transactions on Circuits and Systems II: Express Briefs.

[9]  R. Jacob Baker,et al.  CMOS Circuit Design, Layout, and Simulation , 1997 .

[10]  Siddhartha Sen,et al.  A Differential Output Interfacing ASIC for Integrated Capacitive Sensors , 2018, IEEE Transactions on Instrumentation and Measurement.

[11]  David Blaauw,et al.  A Dual-Slope Capacitance-to-Digital Converter Integrated in an Implantable Pressure-Sensing System , 2014, IEEE Journal of Solid-State Circuits.

[12]  Enrique Prefasi,et al.  An energy-efficient 17-bit noise-shaping Dual-Slope Capacitance-to-Digital Converter for MEMS sensors , 2016, ESSCIRC Conference 2016: 42nd European Solid-State Circuits Conference.

[13]  Eric A. M. Klumperink,et al.  A 10-bit Charge-Redistribution ADC Consuming 1.9 $\mu$W at 1 MS/s , 2010, IEEE Journal of Solid-State Circuits.

[14]  Nicholas G. Dagalakis,et al.  Embedded Capacitive Displacement Sensor for Nanopositioning Applications , 2011, IEEE Transactions on Instrumentation and Measurement.

[15]  Ebrahim Ghafar-Zadeh,et al.  Bacteria Growth Monitoring Through a Differential CMOS Capacitive Sensor , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[16]  Ampalavanapillai Nirmalathas,et al.  An Energy-Efficient Miniaturized Intracranial Pressure Monitoring System , 2017, IEEE Journal of Solid-State Circuits.

[17]  L. Benini,et al.  CMOS DNA Sensor Array With Integrated A/D Conversion Based on Label-Free Capacitance Measurement , 2006, IEEE Journal of Solid-State Circuits.

[18]  D. Strle,et al.  Surface-Functionalized COMB Capacitive Sensors and CMOS Electronics for Vapor Trace Detection of Explosives , 2012, IEEE Sensors Journal.

[19]  Robert Puers,et al.  Ultra Low Power Capacitive Sensor Interfaces , 2007 .

[20]  Akira Matsuzawa,et al.  A 9.35-ENOB, 14.8 fJ/conv.-step fully-passive noise-shaping SAR ADC , 2015, 2015 Symposium on VLSI Circuits (VLSI Circuits).

[21]  Javed S. Gaggatur,et al.  High Gain Capacitance Sensor Interface for the Monitoring of Cell Volume Growth , 2017, 2017 30th International Conference on VLSI Design and 2017 16th International Conference on Embedded Systems (VLSID).

[22]  Khaled N. Salama,et al.  A Biosensor-CMOS Platform and Integrated Readout Circuit in 0.18-μm CMOS Technology for Cancer Biomarker Detection , 2017, Sensors.

[23]  V. Jagadeesh Kumar,et al.  Digital Converter for Differential Capacitive Sensors , 2006, IEEE Transactions on Instrumentation and Measurement.

[24]  Youngcheol Chae,et al.  A 1.2-V 8.3-nJ CMOS Humidity Sensor for RFID Applications , 2013, IEEE Journal of Solid-State Circuits.

[25]  Munkyo Seo,et al.  A Highly Linear, Small-Area Analog Front End With Gain and Offset Compensation for Automotive Capacitive Pressure Sensors in 0.35- $\mu $ m CMOS , 2015, IEEE Sensors Journal.

[26]  Abdulaziz Alhoshany,et al.  A 45.8fJ/Step, energy-efficient, differential SAR capacitance-to-digital converter for capacitive pressure sensing , 2016 .

[27]  Youngcheol Chae,et al.  Low Voltage, Low Power, Inverter-Based Switched-Capacitor Delta-Sigma Modulator , 2009, IEEE J. Solid State Circuits.

[28]  D.J. Young,et al.  A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring , 2009, IEEE Journal of Solid-State Circuits.

[29]  Maliang Liu,et al.  A 6-to-10-Bit 0.5 V-to-0.9 V Reconfigurable 2 MS/s Power Scalable SAR ADC in 0.18 $\mu{\rm m}$ CMOS , 2015, IEEE Transactions on Circuits and Systems I: Regular Papers.

[30]  Eduardo García-Breijo,et al.  Low-Cost Capacitive Humidity Sensor for Application Within Flexible RFID Labels Based on Microcontroller Systems , 2012, IEEE Transactions on Instrumentation and Measurement.

[31]  Khaled N. Salama,et al.  A 33fJ/Step SAR Capacitance-to-Digital Converter Using a Chain of Inverter-Based Amplifiers , 2017, IEEE Transactions on Circuits and Systems I: Regular Papers.

[32]  Boby George,et al.  Analysis of the Switched-Capacitor Dual-Slope Capacitance-to-Digital Converter , 2010, IEEE Transactions on Instrumentation and Measurement.

[33]  Saleh Heidary Shalmany,et al.  27.7 A 0.05mm2 1V capacitance-to-digital converter based on period modulation , 2015, 2015 IEEE International Solid-State Circuits Conference - (ISSCC) Digest of Technical Papers.

[34]  Chulwoo Kim,et al.  Edge-Pursuit Comparator: An Energy-Scalable Oscillator Collapse-Based Comparator With Application in a 74.1 dB SNDR and 20 kS/s 15 b SAR ADC , 2017, IEEE Journal of Solid-State Circuits.

[35]  Zhangming Zhu,et al.  A 0.6-V 38-nW 9.4-ENOB 20-kS/s SAR ADC in 0.18- μm CMOS for Medical Implant Devices. , 2015 .

[36]  A. Matsuzawa,et al.  A 0.026mm2 capacitance-to-digital converter for biotelemetry applications using a charge redistribution technique , 2007, 2007 IEEE Asian Solid-State Circuits Conference.

[37]  Shilpa Sivashankar,et al.  Capacitive immunosensor for C-reactive protein quantification , 2015, 2015 IEEE 58th International Midwest Symposium on Circuits and Systems (MWSCAS).

[38]  Khaled N. Salama,et al.  Matching Properties of Femtofarad and Sub-Femtofarad MOM Capacitors , 2016, IEEE Transactions on Circuits and Systems I: Regular Papers.

[39]  David Blaauw,et al.  27.6 A 0.7pF-to-10nF fully digital capacitance-to-digital converter using iterative delay-chain discharge , 2015, 2015 IEEE International Solid-State Circuits Conference - (ISSCC) Digest of Technical Papers.

[40]  Daniel Dias,et al.  Inkjet Printed Pressure Sensing Platform for Postural Imbalance Monitoring , 2015, IEEE Transactions on Instrumentation and Measurement.

[41]  Nan Sun,et al.  A 55 fJ / conv-step Hybrid SAR-VCO ∆ Σ Capacitance-to-Digital Converter in 40 nm CMOS , 2016 .

[42]  Kofi A. A. Makinwa,et al.  A capacitance-to-digital converter for displacement sensing with 17b resolution and 20μs conversion time , 2012, 2012 IEEE International Solid-State Circuits Conference.

[43]  Mohamed Eddaoudi,et al.  MOFs for the Sensitive Detection of Ammonia: Deployment of fcu-MOF Thin Films as Effective Chemical Capacitive Sensors. , 2017, ACS sensors.

[44]  David Blaauw,et al.  15.4b incremental sigma-delta capacitance-to-digital converter with zoom-in 9b asynchronous SAR , 2014, 2014 Symposium on VLSI Circuits Digest of Technical Papers.

[45]  Michael P. Flynn,et al.  A 90-MS/s 11-MHz-Bandwidth 62-dB SNDR Noise-Shaping SAR ADC , 2012, IEEE Journal of Solid-State Circuits.