Reactive power capability of the wind turbine with Doubly Fed Induction Generator

With the increasing integration into power grids, wind power plants play an important role in the power system. Many requirements for the wind power plants have been proposed in the grid codes. According to these grid codes, wind power plants should have the ability to perform voltage control and reactive power compensation at the point of common coupling (PCC). Besides the shunt flexible alternating current transmission system (FACTS) devices such as the static var compensator (SVC) and the static synchronous compensator (STATCOM), the wind turbine itself can also provide a certain amount of reactive power compensation, depending on the wind speed and the active power control strategy. This paper analyzes the reactive power capability of Doubly Fed Induction Generator (DFIG) based wind turbine, considering the rated stator current limit, the rated rotor current limit, the rated rotor voltage limit, and the reactive power capability of the grid side convertor (GSC). The boundaries of reactive power capability of DFIG based wind turbine are derived. The result was obtained using the software MATLAB.

[1]  S. N. Singh,et al.  Reactive power capability of unified DFIG for wind power generation , 2010, IEEE PES General Meeting.

[2]  Bin Wu,et al.  Power Conversion and Control of Wind Energy Systems , 2011 .

[3]  Poul Ejnar Sørensen,et al.  Reactive power capability of a wind turbine with doubly fed induction generator , 2007 .

[4]  Jesus Lopez Doubly Fed Induction Machine , 2011 .

[5]  Lie Xu,et al.  Coordinated reactive power control for facilitating fault ride through of doubly fed induction generator- and fixed speed induction generator-based wind farms , 2010 .

[6]  S. M. Islam,et al.  Transient Control of DFIG-Based Wind Power Plants in Compliance With the Australian Grid Code , 2012, IEEE Transactions on Power Electronics.

[7]  Wei Qiao,et al.  Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming , 2009 .

[8]  H. Polinder,et al.  General Model for Representing Variable-Speed Wind Turbines in Power System Dynamics Simulations , 2002, IEEE Power Engineering Review.

[9]  Nicholas Jenkins,et al.  Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm , 2004 .

[10]  Birgitte Bak-Jensen,et al.  Wind Power Plant Control - An Overview , 2010 .

[11]  Geng Yang,et al.  LVRT Capability of DFIG-Based WECS Under Asymmetrical Grid Fault Condition , 2013, IEEE Transactions on Industrial Electronics.

[12]  G. Venkataramanan,et al.  A Unified Architecture for Doubly Fed Induction Generator Wind Turbines using a Parallel Grid Side Rectifier and Series Grid Side Converter , 2007, 2007 Power Conversion Conference - Nagoya.

[13]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.