Non-disruptive and null-deflection mass flow measurement by a pressure compensation technique

Accurate mass flow measurement is very important in various monitoring and control applications. This paper proposes a novel method of fluid flow measurement by compensating the pressure drop across the ends of measuring unit using a compensating pump. The pressure drop due to the flow is balanced by a feedback control loop. This is a null-deflection type of measurement. As the insertion of such a measuring unit does not affect the functioning of the systems, this is also a non-disruptive flow measurement method. The implementation and design of such a unit are discussed. The system is modeled and simulated using the bond graph technique and it is experimentally validated. (C) 2009 Elsevier Ltd. All rights reserved.

[1]  Roland W. Jeppson,et al.  Hydraulics of Pipeline Systems , 1999 .

[2]  Andrew W. Palmer,et al.  Optical-fibre sensor technology: a challenge to microelectronic sensors? , 1992 .

[3]  M. Anklin,et al.  Coriolis mass flowmeters: Overview of the current state of the art and latest research , 2006 .

[4]  Zhiqiang Sun,et al.  A study of mass flow rate measurement based on the vortex shedding principle , 2006 .

[5]  Alan S. Perelson,et al.  System Dynamics: A Unified Approach , 1976, IEEE Transactions on Systems, Man, and Cybernetics.

[6]  Katsuhiko Ogata,et al.  Modern Control Engineering , 1970 .

[7]  Michitsugu Mori,et al.  Ultrasonic pulse-Doppler flow meter application for hydraulic power plants , 2008 .

[8]  H. Craighead,et al.  A micromechanical flow sensor for microfluidic applications , 2004, Journal of Microelectromechanical Systems.

[9]  K.P. Pullen,et al.  Design, fabrication and characterization of an axial-flow turbine for flow sensing , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[10]  Muhammet Köksal,et al.  Derivation of state and output equations for systems containing switches and a novel definition of a switch using the bond graph model , 1997 .

[11]  A.F.P. van Putten,et al.  A silicon bidirectional flow sensor for measuring respiratory flow , 1997, IEEE Transactions on Biomedical Engineering.

[12]  Manus P. Henry,et al.  High precision Coriolis mass flow measurement applied to small volume proving , 2006 .

[13]  J. P. Herzog An optical fibre vortex sensor for flowrate measurements , 1992 .

[14]  E. L. Upp,et al.  Fluid Flow Measurement: A Practical Guide to Accurate Flow Measurement , 1993 .

[15]  Kenji Kawashima,et al.  A study of characteristics of pitot type flow meter , 2003, SICE 2003 Annual Conference (IEEE Cat. No.03TH8734).

[16]  I. Itoh,et al.  Mass flowmeter detecting fluctuations in lift generated by vortex shedding , 1993 .

[17]  M. Takamoto,et al.  New measurement method for very low liquid flow rates using ultrasound , 2001 .

[18]  Yong Yan,et al.  Detecting the blockage of the sensing lines of a differential-pressure flow sensor in a dynamic process using wavelet transform techniques , 2006, IEEE Transactions on Instrumentation and Measurement.