Evaluation of Heat Exchange Rate in Horizontal Slinky and Coil Type Ground Heat Exchangers Considering Pitch Interval

The need of geothermal energy is constantly increasing for economical and environmental utilization. Horizontal ground heat exchangers (GHEs) can reduce installation cost and increase efficiency. There are many kinds of GHEs, and it is known that slinky and spiral coil type GHEs show high thermal performance. Therefore, this paper presents experimental results of heat exchange rates in horizontal slinky and spiral coil type GHEs installed in a steel box whose size is . Dried Joomunjin standard sand was filled in a steel box, and thermal response tests (TRTs) were conducted for 30 hours to evaluate heat exchange rates by changing different pitch spaces of horizontal slinky and spiral coil type GHEs. As a result, spiral coil type GHE showed 30~40% higher heat exchange rates per pipe length than horizontal slinky type GHEs. Furthermore, long pitch interval (Pitch/Diameter

[1]  Hyunku Park,et al.  Case study of heat transfer behavior of helical ground heat exchanger , 2012 .

[2]  Seung-Rae Lee,et al.  Design of spiral coil PHC energy pile considering effective borehole thermal resistance and groundwater advection effects , 2014 .

[3]  Galip Temir,et al.  Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification , 2009 .

[4]  Ian W. Johnston,et al.  Emerging geothermal energy technologies , 2011 .

[5]  Majdi Hazami,et al.  In-field performance analysis of ground source cooling system with horizontal ground heat exchanger in Tunisia , 2013 .

[6]  Seung-Rae Lee,et al.  Thermal transfer behavior in two types of W-shape ground heat exchangers installed in multilayer soils , 2014 .

[7]  Gao Jun,et al.  Evaluation of heat exchange rate of GHE in geothermal heat pump systems. , 2009 .

[8]  Lyesse Laloui,et al.  Experimental and numerical investigations of the behaviour of a heat exchanger pile , 2006 .

[9]  Eduardo Blanco,et al.  Numerical Investigation of Horizontal Ground Coupled Heat Exchanger , 2011 .

[10]  Seung-Rae Lee,et al.  Numerical evaluation of the effects of groundwater flow on borehole heat exchanger arrays , 2013 .

[11]  Xu Zhang,et al.  Numerical and experimental assessment of thermal performance of vertical energy piles: An application , 2008 .

[12]  H. Brandl Energy foundations and other thermo-active ground structures , 2006 .

[13]  Gianpiero Colangelo,et al.  CFD simulations of horizontal ground heat exchangers: A comparison among different configurations , 2012 .

[14]  Guohui Gan,et al.  Simulation of thermal performance of horizontal slinky-loop heat exchangers for ground source heat pumps , 2013 .

[15]  Seung-Rae Lee,et al.  Prediction of Heat Exchange Rate in PHC Energy Piles , 2013 .

[16]  Nurettin Yamankaradeniz,et al.  Experimental study of horizontal ground source heat pump performance for mild climate in Turkey , 2009 .

[17]  Hangseok Choi,et al.  Evaluation of Conventional Prediction Models for Soil Thermal Conductivity to Design Horizontal Ground Heat Exchangers , 2013 .

[18]  Guohui Gan,et al.  Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers , 2010 .