Design and control of hybrid actuation lower limb exoskeleton

In this article, two types of actuators are applied for a lower limb exoskeleton. They are DC motors with the harmonic drive and the pneumatic artificial muscles. This combination takes advantages of both the harmonic drive and the pneumatic artificial muscle. It provides both high accuracy position control and high ratio of strength and weight. The shortcomings of the two actuators are overcome by the hybrid actuation, for example, low control accuracy and modeling difficult of pneumatic artificial muscle, compactness, and structural flexibility of DC motors. The design and modeling processes are discussed to show the proposed exoskeleton can increase the strength of human lower limbs. Experiments and analysis of the exoskeleton are given to evaluate the effectiveness of the design and modeling.

[1]  H. Goldstein,et al.  The rise of the body bots [robotic exoskeletons] , 2005, IEEE Spectrum.

[2]  Conor James Walsh,et al.  An autonomous, underactuated exoskeleton for load-carrying augmentation , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[3]  N. Costa,et al.  Control of a Biomimetic "Soft-actuated" 10DoF Lower Body Exoskeleton , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[4]  Homayoon Kazerooni,et al.  Exoskeletons for human power augmentation , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[5]  H. van der Kooij,et al.  Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[6]  J. Mehrholz,et al.  Gait training with the newly developed ‘LokoHelp’-system is feasible for non-ambulatory patients after stroke, spinal cord and brain injury. A feasibility study , 2008, Brain injury.

[7]  Alexander Hošovský,et al.  Dinamičko modeliranje aktuatora na bazi pneumatskog mišića s jednim stupnjem slobode za industrijsku primjenu , 2012 .

[8]  D. Winter Biomechanics and motor control of human gait: normal, elderly and pathological - 2nd edition , 1991 .

[9]  Alexander Hošovský,et al.  DYNAMIC MODELING OF ONE DEGREE OF FREEDOM PNEUMATIC MUSCLE-BASED ACTUATOR FOR INDUSTRIAL APPLICATIONS , 2012 .

[10]  C. Phillips,et al.  Modeling the Dynamic Characteristics of Pneumatic Muscle , 2003, Annals of Biomedical Engineering.

[11]  S.K. Agrawal,et al.  Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients , 2007, 2007 IEEE 10th International Conference on Rehabilitation Robotics.

[12]  R. Contini Body segment parameters. II. , 1972, Artificial limbs.

[13]  Reymond Clavel,et al.  A new concept of parallel robot for rehabilitation and fitness: The Lambda , 2009, 2009 IEEE International Conference on Robotics and Biomimetics (ROBIO).

[14]  Shahid Hussain,et al.  An intrinsically compliant robotic orthosis for treadmill training. , 2012, Medical engineering & physics.

[15]  V. I. Gervini,et al.  A new robotic drive joint friction compensation mechanism using neural networks , 2003 .

[16]  J. P. Chretien,et al.  Dynamic modelling and friction compensated control of a robot manipulator joint , 1992, Proceedings 1992 IEEE International Conference on Robotics and Automation.

[17]  H. Kawamoto,et al.  Power assist method for HAL-3 using EMG-based feedback controller , 2003, SMC'03 Conference Proceedings. 2003 IEEE International Conference on Systems, Man and Cybernetics. Conference Theme - System Security and Assurance (Cat. No.03CH37483).

[18]  Keiko Homma,et al.  A wire-driven leg rehabilitation system: development of a 4-DOF experimental system , 2003, Proceedings 2003 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM 2003).