Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel models.

As clinical trials of Neutron Capture Therapy (NCT) are initiated in the U.S. and other countries, new treatment planning codes are being developed to calculate detailed dose distributions in patient-specific models. The thorough evaluation and comparison of treatment planning codes is a critical step toward the eventual standardization of dosimetry, which, in turn, is an essential element for the rational comparison of clinical results from different institutions. In this paper we report development of a reference suite of computational test problems for NCT dosimetry and discuss common issues encountered in these calculations to facilitate quantitative evaluations and comparisons of NCT treatment planning codes. Specifically, detailed depth-kerma rate curves were calculated using the Monte Carlo radiation transport code MCNP4B for four different representations of the modified Snyder head phantom, an analytic, multishell, ellipsoidal model, and voxel representations of this model with cubic voxel sizes of 16, 8, and 4 mm. Monoenergetic and monodirectional beams of 0.0253 eV, 1, 2, 10, 100, and 1000 keV neutrons, and 0.2, 0.5, 1, 2, 5, and 10 MeV photons were individually simulated to calculate kerma rates to a statistical uncertainty of <1% (1 std. dev.) in the center of the head model. In addition, a "generic" epithermal neutron beam with a broad neutron spectrum, similar to epithermal beams currently used or proposed for NCT clinical trials, was computed for all models. The thermal neutron, fast neutron, and photon kerma rates calculated with the 4 and 8 mm voxel models were within 2% and 4%, respectively, of those calculated for the analytical model. The 16 mm voxel model produced unacceptably large discrepancies for all dose components. The effects from different kerma data sets and tissue compositions were evaluated. Updating the kerma data from ICRU 46 to ICRU 63 data produced less than 2% difference in kerma rate profiles. The depth-dose profile data, Monte Carlo code input, kerma factors, and model construction files are available electronically to aid in verifying new and existing NCT treatment planning codes.

[1]  Mamoru BABA,et al.  Japanese Evaluated Nuclear Data Library Version 3 Revision-3: JENDL-3.3 , 2002 .

[2]  J. T. Goorley Boron neutron capture therapy treatment planning improvements , 1998 .

[3]  H. Takano,et al.  Japanese Evaluated Nuclear Data Library Version 3 Revision-3: JENDL-3.3 , 2002 .

[4]  S M Seltzer,et al.  Calculation of photon mass energy-transfer and mass energy-absorption coefficients. , 1993, Radiation research.

[5]  J. D. Court,et al.  ENDF/B-VI data for MCNP{trademark} , 1994 .

[6]  R A Brooks,et al.  Explanation of cerebral white--gray contrast in computed tomography. , 1980, Journal of computer assisted tomography.

[7]  M. L. Randolph,et al.  Kerma Factors for Neutron Energies below 30 MeV , 1980 .

[8]  O K Harling,et al.  Monte Carlo based dosimetry and treatment planning for neutron capture therapy of brain tumors. , 1990, Basic life sciences.

[9]  Y. Oda [Boron neutron capture therapy]. , 1989, Nihon geka hokan. Archiv fur japanische Chirurgie.

[10]  Allan F. Henry,et al.  Nuclear Reactor Analysis , 1977, IEEE Transactions on Nuclear Science.

[11]  Michael W. Frandsen Rapid geometry interrogation for a uniform volume element-based Monte Carlo particle transport simulation , 1998 .

[12]  M. Palmer,et al.  A Pharmacokinetic Model for the Concentration of 10B in Blood after Boronophenylalanine-Fructose Administration in Humans , 2001, Radiation research.

[13]  J. S. Hendricks,et al.  Monte Carlo photon benchmark problems , 1991 .

[14]  J. Smathers,et al.  The Modern Technology of Radiation Oncology: A Compendium for Medical Physicists and Radiation Oncologists , 1999 .

[15]  R. L. Childs,et al.  TORT: A Three-Dimensional Discrete Ordinates Neutron/Photon Transport Code , 1987 .

[16]  H. B. Liu,et al.  Derivations of relative biological effectiveness for the high-let radiations produced during boron neutron capture irradiations of the 9L rat gliosarcoma in vitro and in vivo. , 1993, International journal of radiation oncology, biology, physics.

[17]  M. L. Randolph,et al.  Kerma factors of elements and compounds for neutron energies below 30 MeV , 1982 .

[18]  B. Mijnheer,et al.  A fast and accurate treatment planning method for boron neutron capture therapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  T. Buchholz,et al.  Boron neutron capture therapy: a mechanism for achieving a concomitant tumor boost in fast neutron radiotherapy. , 1994, International journal of radiation oncology, biology, physics.

[20]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[21]  O. Harling,et al.  A physical dosimetry intercomparison for BNCT. , 2002, Medical physics.

[22]  J. Hopewell,et al.  Central nervous system tolerance to boron neutron capture therapy with p-boronophenylalanine. , 1997, British Journal of Cancer.

[23]  W. S. Kiger,et al.  MacNCTPlan: An improved Macintosh-based BNCT treatment planning program , 1996 .

[24]  A Beddoe,et al.  A Code of practive for the dosimetry of BNCT in Europe , 1998 .

[25]  O. Harling,et al.  Monte Carlo-based treatment planning for boron neutron capture therapy using custom designed models automatically generated from CT data. , 1996, International journal of radiation oncology, biology, physics.

[26]  Gregg W. McKinney,et al.  MCNP Enhancements, Parallel Computing, and Error Analysis for BNCTa , 2001 .

[27]  J. H. Hubbell,et al.  Photon mass attenuation and energy-absorption coefficients , 1982 .

[28]  D W Nigg,et al.  Demonstration of three-dimensional deterministic radiation transport theory dose distribution analysis for boron neutron capture therapy. , 1991, Medical physics.

[29]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[30]  O. Harling,et al.  Mixed field dosimetry of epithermal neutron beams for boron neutron capture therapy at the MITR-II research reactor. , 1994, Medical physics.

[31]  J. S. Hendricks,et al.  MCNP: Neutron benchmark problems , 1991 .

[32]  O. Harling,et al.  Head phantoms for neutron capture therapy. , 1995, Medical physics.

[33]  S. Ye Boron self-shielding effects on dose delivery of neutron capture therapy using epithermal beam and boronophenylalanine. , 1999, Medical physics.

[34]  N. Gupta,et al.  Boron neutron capture therapy of brain tumors: an emerging therapeutic modality. , 1999, Neurosurgery.

[35]  Floyd J. Wheeler,et al.  Computational dosimetry and treatment planning for Boron Neutron Capture Therapy , 1997, Journal of Neuro-Oncology.

[36]  Karsten P. Ulland,et al.  Vii. References , 2022 .

[37]  J. Coderre,et al.  The radiation biology of boron neutron capture therapy. , 1999, Radiation research.

[38]  G. Hehn,et al.  Principles of Radiation Shielding , 1986 .

[39]  A. Kaye,et al.  Boron Neutron Capture Therapy of Brain Tumors: An Emerging Therapeutic Modality , 1999 .

[40]  戴 光曦,et al.  核素图册 = Chart of the nuclides , 1987 .

[41]  Reinhard W. Schulte,et al.  Nuclear Data for Neutron and Proton Radiotherapy and for Radiation Protection , 2001 .

[42]  A Wambersie,et al.  A consistent set of neutron kerma coefficients from thermal to 150 MeV for biologically important materials. , 1999, Medical physics.

[43]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[44]  James A. Scott Photon, Electron, Proton and Neutron Interaction Data for Body Tissues ICRU Report 46. International Commission on Radiation Units and Measurements, Bethesda, 1992, $40.00 , 1993 .

[45]  D. Nigg Methods for radiation dose distribution analysis and treatment planning in boron neutron capture therapy. , 1994, International journal of radiation oncology, biology, physics.

[46]  R. Barth,et al.  The Chemistry of Neutron Capture Therapy. , 1998, Chemical reviews.

[47]  Kent J. Riley,et al.  Construction and characterization of a fission converter based epithermal neutron beam for BNCT , 2001 .

[48]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.