MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: segment-specific attainable precision and breathing influence

ObjectThe objective of this study was to evaluate breathing influence on precision in temperature determination by using the proton resonance frequency (PRF) shift method depending on the location in abdominal organs at 0.2 and 1.5 T.Materials and MethodsPhase images were acquired with gradient echo sequences in a total of 12 volunteers at 1.5 and 0.2 T. Different examination protocols were performed (each 8 measurements with (1) in-/expiration, (2) free breathing, (3) under breathhold, (4) with breathing belt triggering, and (5) with navigator triggering (integrated in MR signal acquisition). Regions of interest were placed on liver and kidneys, and the resulting phase differences between the measurements were transformed into corresponding temperature differences.ResultsPrecision significantly varied depending on the liver segment or location in the kidney. Gating techniques were found better than breathhold techniques and clearly better than non-gated examinations. The most precise approach reached a standard deviation of 2.0°C under continuous breathing when navigator gating was used at 1.5 T.ConclusionPRF temperature measurement is feasible even for moving organs in the abdomen at 0.2 and 1.5 T. The location of the target region and the required precision of the measurements should direct the choice of examination mode.

[1]  Chris J G Bakker,et al.  Correction of proton resonance frequency shift temperature maps for magnetic field disturbances using fat signal , 2007, Journal of magnetic resonance imaging : JMRI.

[2]  M. Olschewski,et al.  Cryoablation of malignant liver tumors: results of a single center study. , 2005, Hepatobiliary & pancreatic diseases international : HBPD INT.

[3]  René M. Botnar,et al.  Temperature quantification using the proton frequency shift technique: In vitro and in vivo validation in an open 0.5 tesla interventional MR scanner during RF ablation , 2001, Journal of magnetic resonance imaging : JMRI.

[4]  J. Hindman,et al.  Proton Resonance Shift of Water in the Gas and Liquid States , 1966 .

[5]  K. Hynynen,et al.  Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam , 1996, Magnetic resonance in medicine.

[6]  K. Vigen,et al.  In vivo porcine liver radiofrequency ablation with simultaneous MR temperature imaging , 2006, Journal of magnetic resonance imaging : JMRI.

[7]  R M Henkelman,et al.  Ex vivo tissue‐type independence in proton‐resonance frequency shift MR thermometry , 1998, Magnetic resonance in medicine.

[8]  Wen-Zhi Chen,et al.  Extracorporeal High Intensity Focused Ultrasound Ablation in the Treatment of Patients with Large Hepatocellular Carcinoma , 2004, Annals of Surgical Oncology.

[9]  P van Gelderen,et al.  Fast magnetic-resonance temperature imaging. , 1996, Journal of magnetic resonance. Series B.

[10]  Bruno Quesson,et al.  Magnetic resonance temperature imaging for guidance of thermotherapy , 2000, Journal of magnetic resonance imaging : JMRI.

[11]  R M Henkelman,et al.  Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle , 1998, Magnetic resonance in medicine.

[12]  G. Dodd,et al.  Sonographically observed echogenic response during intraoperative radiofrequency ablation of cirrhotic livers: pathologic correlation. , 2002, AJR. American journal of roentgenology.

[13]  G S Gazelle,et al.  Radiofrequency tissue ablation: physical principles and techniques for increasing coagulation necrosis. , 2001, Hepato-gastroenterology.

[14]  Martin G Mack,et al.  Colorectal carcinoma metastases in liver: laser-induced interstitial thermotherapy--local tumor control rate and survival data. , 2004, Radiology.

[15]  A. Shmatukha,et al.  Correction of proton resonance frequency shift temperature maps for magnetic field disturbances caused by breathing , 2006, Physics in medicine and biology.

[16]  C. Moonen,et al.  Real time monitoring of radiofrequency ablation based on MR thermometry and thermal dose in the pig liver in vivo , 2008, European Radiology.

[17]  K. Kuroda,et al.  A precise and fast temperature mapping using water proton chemical shift , 1995, Magnetic resonance in medicine.

[18]  Xiao-Yan Xie,et al.  Percutaneous microwave and radiofrequency ablation for hepatocellular carcinoma: a retrospective comparative study , 2005, Journal of Gastroenterology.

[19]  F A Jolesz,et al.  MR imaging of laser-tissue interactions. , 1988, Radiology.

[20]  D L Parker,et al.  Temperature distribution measurements in two-dimensional NMR imaging. , 1983, Medical physics.

[21]  H. D. Patterson,et al.  Recovery of inter-block information when block sizes are unequal , 1971 .

[22]  J S Lewin,et al.  Temperature measurement using echo‐shifted FLASH at low field for interventional MRI , 1999, Journal of magnetic resonance imaging : JMRI.

[23]  Bruno Quesson,et al.  Real‐time monitoring of radiofrequency ablation of rabbit liver by respiratory‐gated quantitative temperature MRI , 2006, Journal of magnetic resonance imaging : JMRI.

[24]  Bruno Quesson,et al.  Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver: an ex vivo study , 2006, European Radiology.

[25]  D E Dupuy,et al.  Image-guided radiofrequency tumor ablation: challenges and opportunities--part I. , 2001, Journal of vascular and interventional radiology : JVIR.

[26]  W. Hedrick,et al.  Absorbed dose to the fetus during bone scintigraphy. , 1988, Radiology.

[27]  Goldberg Sn,et al.  Radiofrequency tissue ablation: physical principles and techniques for increasing coagulation necrosis. , 2001 .

[28]  Bruno Quesson,et al.  Stability of real‐time MR temperature mapping in healthy and diseased human liver , 2004, Journal of magnetic resonance imaging : JMRI.

[29]  K. Hynynen,et al.  Simultaneous magnetic resonance phase and magnitude temperature maps in muscle , 1996, Magnetic resonance in medicine.

[30]  Fritz Schick,et al.  Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method , 2005, Journal of magnetic resonance imaging : JMRI.

[31]  J A de Zwart,et al.  On‐line correction and visualization of motion during MRI‐controlled hyperthermia , 2001, Magnetic resonance in medicine.

[32]  F A Jolesz,et al.  MR imaging-guided percutaneous cryotherapy of liver tumors: initial experience. , 2000, Radiology.

[33]  Thermal diffusivity and nuclear spin relaxation: a continuous wave free precession NMR study. , 2006, Journal of magnetic resonance.

[34]  Waldemar Wlodarczyk,et al.  Noninvasive magnetic resonance thermography of soft tissue sarcomas during regional hyperthermia , 2006, Cancer.

[35]  John M Pauly,et al.  Triggered, navigated, multi‐baseline method for proton resonance frequency temperature mapping with respiratory motion , 2003, Magnetic resonance in medicine.

[36]  J. Poorter,et al.  Noninvasive MRI Thermometry with the Proton Resonance Frequency (PRF) Method: In Vivo Results in Human Muscle , 1995, Magnetic resonance in medicine.

[37]  J. De Poorter,et al.  Noninvasive MRI thermometry with the proton resonance frequency method: study of susceptibility effects. , 1995, Magnetic resonance in medicine.