Comparison of computer-aided detection (CADe) capability for pulmonary nodules among standard-, reduced- and ultra-low-dose CTs with and without hybrid type iterative reconstruction technique.

PURPOSE To directly compare the effect of a reconstruction algorithm on nodule detection capability of the computer-aided detection (CADe) system using standard-dose, reduced-dose and ultra-low dose chest CTs with and without adaptive iterative dose reduction 3D (AIDR 3D). MATERIALS AND METHODS Our institutional review board approved this study, and written informed consent was obtained from each patient. Standard-, reduced- and ultra-low-dose chest CTs (250 mA, 50 mA and 10 mA) were used to examine 40 patients, 21 males (mean age ± standard deviation: 63.1 ± 11.0 years) and 19 females (mean age, 65.1 ± 12.7 years), and reconstructed as 1 mm-thick sections. Detection of nodule equal to more than 4 mm in dimeter was automatically performed by our proprietary CADe software. The utility of iterative reconstruction method for improving nodule detection capability, sensitivity and false positive rate (/case) of the CADe system using all protocols were compared by means of McNemar's test or signed rank test. RESULTS Sensitivity (SE: 0.43) and false-positive rate (FPR: 7.88) of ultra-low-dose CT without AIDR 3D was significantly inferior to those of standard-dose CTs (with AIDR 3D: SE, 0.78, p < .0001, FPR, 3.05, p < .0001; and without AIDR 3D: SE, 0.80, p < .0001, FPR: 2.63, p < .0001), reduced-dose CTs (with AIDR 3D: SE, 0.81, p < .0001, FPR, 3.05, p < .0001; and without AIDR 3D: SE, 0.62, p < .0001, FPR: 2.95, p < .0001) and ultra-low-dose CT with AIDR 3D (SE, 0.79, p < .0001, FPR, 4.88, p = .0001). CONCLUSION The AIDR 3D has a significant positive effect on nodule detection capability of the CADe system even when radiation dose is reduced.

[1]  A. Dirksen,et al.  CT screening for lung cancer brings forward early disease. The randomised Danish Lung Cancer Screening Trial: status after five annual screening rounds with low-dose CT , 2012, Thorax.

[2]  J. Austin,et al.  Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. , 2005, Radiology.

[3]  Takeshi Yoshikawa,et al.  Adaptive iterative dose reduction using 3D processing for reduced- and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings. , 2012, AJR. American journal of roentgenology.

[4]  Marco Das,et al.  Small pulmonary nodules: effect of two computer-aided detection systems on radiologist performance. , 2006, Radiology.

[5]  A. Bankier,et al.  Guidelines for Management of Incidental Pulmonary Nodules Detected on CT Images: From the Fleischner Society 2017. , 2017, Radiology.

[6]  S. Matsumoto,et al.  A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT , 2015, Japanese Journal of Radiology.

[7]  S. Matsumoto,et al.  Computer-aided detection of lung nodules on multidetector row computed tomography using three-dimensional analysis of nodule candidates and their surroundings , 2008, Radiation Medicine.

[8]  A. Reeves,et al.  Automated detection of small pulmonary nodules in whole lung CT scans. , 2007, Academic radiology.

[9]  Kenji Suzuki A review of computer-aided diagnosis in thoracic and colonic imaging. , 2012, Quantitative imaging in medicine and surgery.

[10]  Toru Higaki,et al.  Effects of Iterative Reconstruction Algorithms on Computer-assisted Detection (CAD) Software for Lung Nodules in Ultra-low-dose CT for Lung Cancer Screening. , 2017, Academic radiology.

[11]  Sumit K. Shah,et al.  Computer-aided lung nodule detection in CT: results of large-scale observer test. , 2005, Academic radiology.

[12]  Ali O. Farooqi,et al.  Lung cancers diagnosed at annual CT screening: volume doubling times. , 2012, Radiology.

[13]  T. Mizoue,et al.  Long-term prognosis of patients with lung cancer detected on low-dose chest computed tomography screening. , 2012, Lung cancer.

[14]  C. Gatsonis,et al.  Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening , 2012 .

[15]  K. Bae,et al.  Pulmonary nodules: automated detection on CT images with morphologic matching algorithm--preliminary results. , 2005, Radiology.

[16]  Sumiaki Matsumoto,et al.  Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: a comparative study. , 2013, European journal of radiology.

[17]  J. Goo A Computer-Aided Diagnosis for Evaluating Lung Nodules on Chest CT: the Current Status and Perspective , 2011, Korean journal of radiology.

[18]  M. Scorsetti,et al.  Long-Term Follow-up Results of the DANTE Trial, a Randomized Study of Lung Cancer Screening with Spiral Computed Tomography. , 2015, American journal of respiratory and critical care medicine.

[19]  A. Bankier,et al.  Through the Looking Glass revisited: the need for more meaning and less drama in the reporting of dose and dose reduction in CT. , 2012, Radiology.

[20]  J. Goo,et al.  Computer-Aided Nodule Detection and Volumetry to Reduce Variability Between Radiologists in the Interpretation of Lung Nodules at Low-Dose Screening Computed Tomography , 2012, Investigative radiology.

[21]  Y. Ohno,et al.  Hybrid Type iterative reconstruction method vs. filter back projection method: Capability for radiation dose reduction and perfusion assessment on dynamic first-pass contrast-enhanced perfusion chest area-detector CT. , 2016, European journal of radiology.

[22]  D. Xu,et al.  Nodule management protocol of the NELSON randomised lung cancer screening trial. , 2006, Lung cancer.

[23]  Ella A Kazerooni,et al.  ACR CT accreditation program and the lung cancer screening program designation. , 2015, Journal of the American College of Radiology : JACR.

[24]  Y. Ohno,et al.  Comparative evaluation of newly developed model-based and commercially available hybrid-type iterative reconstruction methods and filter back projection method in terms of accuracy of computer-aided volumetry (CADv) for low-dose CT protocols in phantom study. , 2016, European journal of radiology.

[25]  Tae Jung Kim,et al.  Is the Computer-Aided Detection Scheme for Lung Nodule Also Useful in Detecting Lung Cancer? , 2008, Journal of computer assisted tomography.

[26]  Mitsuru Ikeda,et al.  Lung nodule detection performance in five observers on computed tomography (CT) with adaptive iterative dose reduction using three-dimensional processing (AIDR 3D) in a Japanese multicenter study: Comparison between ultra-low-dose CT and low-dose CT by receiver-operating characteristic analysis. , 2015, European journal of radiology.

[27]  S. Armato,et al.  Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program. , 2002, Radiology.

[28]  Sumiaki Matsumoto,et al.  Potential contribution of multiplanar reconstruction (MPR) to computer-aided detection of lung nodules on MDCT. , 2012, European journal of radiology.

[29]  Annette McWilliams,et al.  Detection Sensitivity of a Commercial Lung Nodule CAD System in a Series of Pathologically Proven Lung Cancers , 2008, Journal of thoracic imaging.

[30]  Harry J de Koning,et al.  Management of lung nodules detected by volume CT scanning. , 2009, The New England journal of medicine.

[31]  Takeshi Yoshikawa,et al.  Emphysema quantification on low-dose CT using percentage of low-attenuation volume and size distribution of low-attenuation lung regions: effects of adaptive iterative dose reduction using 3D processing. , 2014, European journal of radiology.

[32]  H. D. de Koning,et al.  Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers. , 2014, The Lancet. Oncology.