Microfluidic cartridges preloaded with nanoliter plugs of reagents: an alternative to 96-well plates for screening.

In traditional screening with 96-well plates, microliters of substrates are consumed for each reaction. Further miniaturization is limited by the special equipment and techniques required to dispense nanoliter volumes of fluid. Plug-based microfluidics confines reagents in nanoliter plugs (droplets surrounded by fluorinated carrier fluid), and uses simple pumps to control the flow of plugs. By using cartridges pre-loaded with nanoliter plugs of reagents, only two pumps and a merging junction are needed to set up a screen. Screening with preloaded cartridges uses only nanoliters of substrate per reaction, and requires no microfabrication. The low cost and simplicity of this method has the potential of replacing 96-well and other multi-well plates, and has been applied to enzymatic assays, protein crystallization and optimization of organic reactions.

[1]  Helen Song,et al.  A microfluidic system for controlling reaction networks in time. , 2003, Angewandte Chemie.

[2]  Stephen R Quake,et al.  Parallel picoliter rt-PCR assays using microfluidics. , 2006, Analytical chemistry.

[3]  S. Quake,et al.  Systematic investigation of protein phase behavior with a microfluidic formulator. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[4]  Rustem F Ismagilov,et al.  A droplet-based, composite PDMS/glass capillary microfluidic system for evaluating protein crystallization conditions by microbatch and vapor-diffusion methods with on-chip X-ray diffraction. , 2004, Angewandte Chemie.

[5]  B. Karger,et al.  High-throughput microcoil NMR of compound libraries using zero-dispersion segmented flow analysis. , 2005, Journal of combinatorial chemistry.

[6]  J. Landers,et al.  Fundamentals and practice for ultrasensitive laser‐induced fluorescence detection in microanalytical systems , 2004, Electrophoresis.

[7]  R. Ismagilov,et al.  Screening of protein crystallization conditions on a microfluidic chip using nanoliter-size droplets. , 2003, Journal of the American Chemical Society.

[8]  M. Baldwin Mass spectrometers for the analysis of biomolecules. , 2005, Methods in enzymology.

[9]  Rustem F Ismagilov,et al.  Formation of droplets of alternating composition in microfluidic channels and applications to indexing of concentrations in droplet-based assays. , 2004, Analytical chemistry.

[10]  C. Eggeling,et al.  Fluorescence fluctuation spectroscopy in reduced detection volumes. , 2006, Current pharmaceutical biotechnology.

[11]  S. Quake,et al.  Multistep Synthesis of a Radiolabeled Imaging Probe Using Integrated Microfluidics , 2005, Science.

[12]  Rustem F Ismagilov,et al.  Multi-step synthesis of nanoparticles performed on millisecond time scale in a microfluidic droplet-based system. , 2004, Lab on a chip.

[13]  Helen Song,et al.  Millisecond kinetics on a microfluidic chip using nanoliters of reagents. , 2003, Journal of the American Chemical Society.

[14]  Rustem F Ismagilov,et al.  Using nanoliter plugs in microfluidics to facilitate and understand protein crystallization. , 2005, Current opinion in structural biology.

[15]  Samuel K Sia,et al.  Reagent-loaded cartridges for valveless and automated fluid delivery in microfluidic devices. , 2005, Analytical chemistry.

[16]  Helen Song,et al.  Controlling nonspecific protein adsorption in a plug-based microfluidic system by controlling interfacial chemistry using fluorous-phase surfactants. , 2005, Analytical chemistry.

[17]  Petra Schwille,et al.  Single-molecule spectroscopic methods. , 2004, Current opinion in structural biology.

[18]  Hans Lehrach,et al.  Miniaturization in functional genomics and proteomics , 2005, Nature Reviews Genetics.

[19]  Delai L Chen,et al.  Microgram-scale testing of reaction conditions in solution using nanoliter plugs in microfluidics with detection by MALDI-MS. , 2006, Journal of the American Chemical Society.

[20]  Yuan Wang,et al.  Nanoliter homogenous ultra-high throughput screening microarray for lead discoveries and IC50 profiling. , 2005, Assay and drug development technologies.

[21]  A. L. Burlingame Biological mass spectrometry , 2005 .

[22]  Ruslan Sanishvili,et al.  In situ data collection and structure refinement from microcapillary protein crystallization. , 2005, Journal of applied crystallography.

[23]  M. Jemal High-throughput quantitative bioanalysis by LC/MS/MS. , 2000, Biomedical chromatography : BMC.

[24]  Hyun Gyu Park,et al.  Fluorescence-based assay formats and signal amplification strategies for DNA microarray analysis , 2006 .

[25]  Rustem F Ismagilov,et al.  A microfluidic approach for screening submicroliter volumes against multiple reagents by using preformed arrays of nanoliter plugs in a three-phase liquid/liquid/gas flow. , 2005, Angewandte Chemie.

[26]  Helen Song,et al.  Formation of droplets and mixing in multiphase microfluidics at low values of the Reynolds and the capillary numbers , 2003 .