Multidirectional Alternating Current Potential Drop Technique for Detecting Random Cracks

The alternating current potential drop technique has been widely used to measure subsurface cracks in metal structures. However, the application of the technique to random cracks has, to date, been limited. By using a multidirectional alternating current potential drop technique, the angle between crack and exciting electrode wire changes from 0° – 90° to 67.5° – 90°, which considerably expanded the ranges of detection. Simulation and experiment results showed that this technique can accurately measure the depth of random cracks.

[1]  W. D. Dover,et al.  THE MEASUREMENT OF SURFACE BREAKING CRACKS BY THE ELECTRICAL SYSTEMS ACPD/ACFM , 1994 .

[2]  Dannie R. Clarida,et al.  Corrosion Monitoring Experience in the Refining Industry Using the FSM Technique , 2003 .

[3]  D. Mirshekar-Syahkal,et al.  The influence of skin depth on crack measurement by the ac field technique , 1982 .

[4]  Nicola Bowler,et al.  Theory of four-point alternating current potential drop measurements on conductive plates , 2007, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[5]  Nicola Bowler,et al.  Four-point potential drop measurements for materials characterization , 2010 .

[6]  Daniel Rittel,et al.  Flaw detection in metals by the ACPD technique: Theory and experiments , 2007 .

[8]  D. Mirshekar-Syahkal Probe characterization in ac field measurements of surface crack depth , 1982 .

[9]  Daniel Rittel,et al.  Alternating current flow in internally flawed conductors: A tomographic analysis , 2006 .

[10]  Chitoshi Miki,et al.  Electrical potential drop method for evaluating crack depth , 1991 .

[11]  W. J. Evans,et al.  Calibration of an ACPD monitoring system for small crack growth in corner crack specimens , 1995 .

[12]  Duan Yi-xiong Accurate measuring of crack-depth , 2010 .

[13]  Peter Cawley,et al.  An approximate model for three-dimensional alternating current potential drop analyses using a commercial finite element code , 2010 .

[14]  Gui Yun Tian,et al.  Investigation of pitting corrosion monitoring using field signature method , 2016 .

[15]  D. Rittel,et al.  Application of ac tomography to crack identification , 2007 .

[16]  D. H. Michael,et al.  The measurement of surface cracks in metals by using a. c. electric fields , 1982, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[17]  T V Venkatsubramanian,et al.  An AC potential drop system for monitoring crack length , 1984 .

[18]  N. Bowler,et al.  Alternating current potential-drop measurement of the depth of case hardening in steel rods , 2008 .

[19]  Junbi Liao,et al.  An SVM approach with alternating current potential drop technique to classify pits and cracks on the bottom of a metal plate , 2016 .

[20]  I. Hwang A multi-frequency AC potential drop technique for the detection of small cracks , 1992 .

[21]  M. Neyrinck,et al.  AN IMPROVED A.C. POTENTIAL DROP METHOD FOR DETECTING SURFACE MICROCRACKS DURING FATIGUE TESTS OF UNNOTCHED SPECIMENS , 1980 .

[22]  Junbi Liao,et al.  Novel Method for Sizing Metallic Bottom Crack Depth Using Multi-frequency Alternating Current Potential Drop Technique , 2015 .

[23]  Yuting Li,et al.  Improved formula for localized corrosion using field signature method , 2015 .

[24]  Laibin Zhang,et al.  Simulation analysis and experimental study of an alternating current field measurement probe for pipeline inner inspection , 2018, NDT & E International.

[25]  Peter Cawley,et al.  Potential drop mapping for the monitoring of corrosion or erosion , 2010 .

[26]  Necar Merah,et al.  Detecting and measuring flaws using electric potential techniques , 2003 .