A statistical analysis of the received signal from blood during laminar flow

In order to determine the limiting velocity resolution that can be achieved using ultrasound, and to provide a model which can be generalized for the analysis of disturbed flow, a theoretical and experimental evaluation of the statistics of the received signal from laminar flow following the transmission of a train of short pulses is presented. The authors derive the autocorrelation function and determine the length of the correlated signal for various flow rates, comparing experimental measurements to theoretical predictions. High resolution experimental RF M-mode images are used to verify the theoretical model. Using a fluid with a density, viscosity, volume concentration, particle size, and speed of sound which is similar to that of blood, the authors show that the signal remains correlated for a long interval under many conditions of clinical interest. Including a comparison with experimental data, the effect of the lateral transit time through the sample volume and the axial velocity spread within the sample volume on the correlation of the received signal is evaluated. When a significant range of velocity components is present within the sample volume, this range is the limiting factor in the length of the correlated signal interval. Therefore, the use of a wideband signal, which reduces the sample volume size, produces a returned signal that may be correlated for a larger number of pulses, or for a longer time.<<ETX>>

[1]  K.W. Ferrara,et al.  A theoretical and experimental analysis of the received signal from disturbed blood flow , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  P R Hoskins,et al.  A comparison of the Doppler spectra from human blood and artificial blood used in a flow phantom. , 1990, Ultrasound in medicine & biology.

[3]  J. Liu,et al.  The effect of frequency dependent scattering and attenuation on the estimation of blood velocity using ultrasound , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  G. Cloutier,et al.  The effects of hematocrit, shear rate, and turbulence on ultrasonic Doppler spectrum from blood , 1992, IEEE Transactions on Biomedical Engineering.

[5]  K.W. Ferrara,et al.  A new wideband spread target maximum likelihood estimator for blood velocity estimation. II. Evaluation of estimator with experimental data , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  R S Cobbold,et al.  Influence of spectral broadening on continuous wave Doppler ultrasound spectra: a geometric approach. , 1986, Ultrasound in medicine & biology.

[7]  Y Douville,et al.  Determination of the hemodynamic factors which influence the carotid Doppler spectral broadening. , 1985, Ultrasound in medicine & biology.

[8]  Richard S. C. Cobbold,et al.  A Stochastic Model of the Backscattered Doppler Ultrasound from Blood , 1986, IEEE Transactions on Biomedical Engineering.

[9]  W. M. Carey,et al.  Digital spectral analysis: with applications , 1986 .

[10]  R. Gill Measurement of blood flow by ultrasound: accuracy and sources of error. , 1985, Ultrasound in medicine & biology.

[11]  L. William Varner,et al.  Geometrical Spectrum Broadening in Ultrasonic Doppler Systems , 1977, IEEE Transactions on Biomedical Engineering.

[12]  Vernon L. Newhouse,et al.  Analysis of Transit Time Effects on Doppler Flow Measurement , 1976, IEEE Transactions on Biomedical Engineering.

[13]  C. Oates,et al.  Towards an ideal blood analogue for Doppler ultrasound phantoms. , 1991, Physics in medicine and biology.

[14]  V. Algazi,et al.  A new wideband spread target maximum likelihood estimator for blood velocity estimation. I. Theory , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.