Feasibility study for markerless tracking of lung tumors in stereotactic body radiotherapy.

PURPOSE To evaluate the feasibility and accuracy of a method for markerless tracking of lung tumors in electronic portal imaging device (EPID) movies and to analyze intra- and interfractional variations in tumor motion. METHODS AND MATERIALS EPID movies were acquired during stereotactic body radiotherapy (SBRT) given to 40 patients with 49 pulmonary targets and retrospectively analyzed. Tumor visibility and tracking accuracy were determined by three observers. Tumor motion of 30 targets was analyzed in detail via four-dimensional computed tomography (4DCT) and EPID in the superior-inferior direction for intra- and interfractional variations. RESULTS Tumor visibility was sufficient for markerless tracking in 47% of the EPID movies. Tumor size and visibility in the DRR were correlated with visibility in the EPID images. The difference between automatic and manual tracking was a maximum of 2 mm for 98.3% in the x direction and 89.4% in the y direction. Motion amplitudes in 4DCT images (range, 0.7-17.9 mm; median, 4.9 mm) were closely correlated with amplitudes in the EPID movies. Intrafractional and interfractional variability of tumor motion amplitude were of similar magnitude: 1 mm on average to a maximum of 4 mm. A change in moving average of more than ±1 mm, ±2 mm, and ±4 mm were observed in 47.1%, 17.1%, and 4.5% of treatment time for all trajectories, respectively. Mean tumor velocity was 3.4 mm/sec, to a maximum 61 mm/sec. CONCLUSIONS Tracking of pulmonary tumors in EPID images without implanted markers was feasible in 47% of all treatment beams. 4DCT is representative of the evaluation of mean breathing motion on average, but larger deviations occurred in target motion between treatment planning and delivery effort a monitoring during delivery.

[1]  Matthias Guckenberger,et al.  Tracking moving objects with megavoltage portal imaging: a feasibility study. , 2006, Medical physics.

[2]  Ross I Berbeco,et al.  Clinical feasibility of using an EPID in CINE mode for image-guided verification of stereotactic body radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[3]  Steve B. Jiang,et al.  Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy , 2009, Physics in medicine and biology.

[4]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[5]  Matthias Guckenberger,et al.  Dose-response relationship for image-guided stereotactic body radiotherapy of pulmonary tumors: relevance of 4D dose calculation. , 2009, International journal of radiation oncology, biology, physics.

[6]  Paul J Keall,et al.  An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients , 2008, Physics in medicine and biology.

[7]  Jeffrey D Bradley,et al.  A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms. , 2006, Medical physics.

[8]  George Starkschall,et al.  Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer. , 2007, International journal of radiation oncology, biology, physics.

[9]  Eric C Ford,et al.  Measurement of lung tumor motion using respiration-correlated CT. , 2004, International journal of radiation oncology, biology, physics.

[10]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[11]  R Mohan,et al.  Determining parameters for respiration-gated radiotherapy. , 2001, Medical physics.

[12]  Klaus Schilling,et al.  Tumor tracking and motion compensation with an adaptive tumor tracking system (ATTS): System description and prototype testing. , 2008, Medical physics.

[13]  Y Shioyama,et al.  Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy , 2009, Physics in medicine and biology.

[14]  Gregory C Sharp,et al.  Speed and amplitude of lung tumor motion precisely detected in four-dimensional setup and in real-time tumor-tracking radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[15]  Tong Lin,et al.  A feasibility study of treatment verification using EPID cine images for hypofractionated lung radiotherapy. , 2009, Physics in medicine and biology.

[16]  Paul J Keall,et al.  Geometric uncertainty of 2D projection imaging in monitoring 3D tumor motion. , 2007, Physics in medicine and biology.

[17]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[18]  Arthur L Boyer,et al.  Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidance. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  P. Keall,et al.  Determination of maximum leaf velocity and acceleration of a dynamic multileaf collimator: implications for 4D radiotherapy. , 2005, Medical physics.

[20]  S Webb,et al.  Target-tracking deliveries using conventional multileaf collimators planned with 4D direct-aperture optimization. , 2008, Physics in medicine and biology.

[21]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[22]  Cedric X. Yu,et al.  Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study , 2005, Physics in medicine and biology.

[23]  Jan-Jakob Sonke,et al.  Variability of four-dimensional computed tomography patient models. , 2008, International journal of radiation oncology, biology, physics.