Surface Point Cloud Ultrasound with Transcranial Doppler: Coregistration of Surface Point Cloud Ultrasound with Magnetic Resonance Angiography for Improved Reproducibility, Visualization, and Navigation in Transcranial Doppler Ultrasound

Transcranial Doppler (TCD) ultrasound is a standard tool used in the setting of recent sub-arachnoid hemorrhage (SAH). By tracking velocity in the circle-of-Willis vessels, vasospasm can be detected as interval velocity increase. For this disease process, repeated TCD velocity measurements over many days is the basis for its usefulness. However, a key limitation to TCD is its user dependence, which is itself largely due to the fact that exact information about probe positioning is lost between subsequent scans. Surface point cloud ultrasound (SPC-US) was recently introduced as a general approach combining ultrasound and three-dimensional surface imaging of patient + probe. In the present proof-of-principle demonstration, we have applied SPC-US to TCD and co-registered the skin surface with that from MRA images to provide a roadmap of the vasculature in 3D space for better speed, accuracy, reproducibility, and potential semi-automation of TCD. Collating the acronyms, we call the combined approach SPC-US-TCD. TCD of the M1 was obtained while three-dimensional photographic images were obtained with the Structure Sensor camera. MRA imaging was also obtained. SPC-US-TCD and corresponding MRA 3D reconstruction images were co-registered in MeshMixer using the skin surfaces for alignment. A cylinder the width of the TCD probe was placed over the fused images and aligned with the direction and orientation of the TCD probe to demonstrate the acoustic beam. In the fused images, the acoustic beam intersects the right M1 segment of the middle cerebral artery (MCA). The angle of insonation is well demonstrated and measurable in various planes. Distance measurements made in Blender localized the TCD probe position based on three skin surface landmarks, and tabulated orientation based on three angles along the corresponding directions. SPC-US-TCD provides valuable information that is otherwise not present in TCD studies. By co-registering SPC-US-TCD data with that from cross sectional vessel imaging, precise probe location relative to external skin surface landmarks as well as 3D vessel location relative to TCD probe placement offers the potential to provide a roadmap that improves exam reproducibility, speed of acquisition, and accuracy. The goal of future work is to demonstrate this improvement statistically by application to multiple patients and scans.

[1]  Joseph N. Stember Three-Dimensional Surface Point Cloud Ultrasound for Better Understanding and Transmission of Ultrasound Scan Information , 2017, Journal of Digital Imaging.

[2]  R. Green,et al.  Measurement of carotid bifurcation pressure gradients using the Bernoulli principle. , 1996, Cardiovascular surgery.

[3]  A. Lupetin,et al.  Transcranial Doppler sonography. Part 1. Principles, technique, and normal appearances. , 1995, Radiographics : a review publication of the Radiological Society of North America, Inc.

[4]  Daniel R Kramer,et al.  Cerebral Vasospasm in Traumatic Brain Injury , 2013, Neurology research international.

[5]  S. Mayer,et al.  Sample Size Estimates for Clinical Trials of Vasospasm in Subarachnoid Hemorrhage , 2009, Stroke.

[6]  J A Zagzebski,et al.  Spectral and color Doppler artifacts. , 1992, Radiographics : a review publication of the Radiological Society of North America, Inc.

[7]  H. Adams,et al.  The International Cooperative Study on the Timing of Aneurysm Surgery. Part 1: Overall management results. , 1990, Journal of neurosurgery.

[8]  M. Blaivas,et al.  Applications of Transcranial Color‐Coded Sonography in the Emergency Department , 2017, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[9]  Soojin Park,et al.  Brain ultrasonography: methodology, basic and advanced principles and clinical applications. A narrative review , 2019, Intensive Care Medicine.

[10]  E. Melhem,et al.  Narrowing of the middle cerebral artery: artificial intelligence methods and comparison of transcranial color coded duplex sonography with conventional TCD. , 2010, Ultrasound in medicine & biology.

[11]  R. Aaslid,et al.  Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. , 1982, Journal of neurosurgery.

[12]  T R Nelson,et al.  The Doppler signal: where does it come from and what does it mean? , 1988, AJR. American journal of roentgenology.

[13]  A. Baker,et al.  Transcranial Doppler monitoring in subarachnoid hemorrhage: a critical tool in critical care , 2008, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[14]  N. Keric,et al.  Image Guidance for Transcranial Doppler Ultrasonography , 2011, Neurosurgery.

[15]  S. Holland,et al.  Doppler US. Part I. Basic principles, instrumentation, and pitfalls. , 1990, Radiology.

[16]  J. Curé,et al.  Radiographic Predictors of Neurocognitive Functioning in Pediatric Sickle Cell Disease , 2006, Journal of child neurology.

[17]  S. Chalon,et al.  Repeatability of transcranial Doppler measurements of arterial blood flow velocities in healthy subjects. , 1993, Clinical science.

[18]  S. Kasner,et al.  Vertebral and Basilar Arteries: Transcranial Color-Coded Duplex Ultrasonography versus Conventional TCD in Detection of Narrowings , 2012, The neuroradiology journal.

[19]  D. Newby,et al.  Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery , 2018, Cardiovascular Ultrasound.

[20]  W. Chadduck,et al.  Transcranial doppler ultrasonography for the evaluation of shunt malfunction in pediatric patients , 1991, Child's Nervous System.

[21]  N. Kassell,et al.  Cerebral vasospasm following aneurysmal subarachnoid hemorrhage. , 1985, Stroke.

[22]  A. Lavinio,et al.  Transcranial Doppler ultrasonography in intensive care , 2008, European journal of anaesthesiology. Supplement.

[23]  A. Giese,et al.  Image-guided Transcranial Doppler Sonography for Monitoring of Defined Segments of Intracranial Arteries , 2013, Journal of neurosurgical anesthesiology.

[24]  B. Venkatesh,et al.  Inter Observer Variability of the Transcranial Doppler Ultrasound Technique: Impact of Lack of Practice on the Accuracy of Measurement , 1999, Journal of Clinical Monitoring and Computing.

[25]  C Kremser,et al.  Transcranial Doppler Sonography Guided by Magnetic Resonance Angiography for Improved Monitoring of Intracranial Arteries , 1999, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[26]  Soojin Park,et al.  Transcranial Doppler Waveforms During Intra-aortic Balloon Pump Counterpulsation for Vasospasm Detection After Subarachnoid Hemorrhage , 2018, Neurosurgery.

[27]  L. Thomsen,et al.  Experimental and biological variation of three-dimensional transcranial Doppler measurements. , 1993, Journal of applied physiology.

[28]  Michele H Johnson,et al.  Advances in transcranial Doppler US: imaging ahead. , 2013, Radiographics : a review publication of the Radiological Society of North America, Inc.

[29]  N. Oku,et al.  A validation study on the reproducibility of transcranial Doppler velocimetry. , 1990, Ultrasound in medicine & biology.

[30]  C. Marck,et al.  Methodology of an International Study of People with Multiple Sclerosis Recruited through Web 2.0 Platforms: Demographics, Lifestyle, and Disease Characteristics , 2013, Neurology research international.

[31]  L. Provinciali,et al.  Intra- and inter-observer variability of basal flow velocity and vascular reactivity measurements using transcranial Doppler sonography. , 1992, Neurological research.