Emissions of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans from Stack Gases of Electric Arc Furnaces and Secondary Aluminum Smelters

Abstract This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD = 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 μg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 μm g I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650–750 °C) are lower than those for EAFs (1600–1700 °C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are ∼27, 53, and ∼24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g ITEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.

[1]  Gev Eduljee,et al.  An updated inventory of potential PCDD and PCDF emission sources in the UK , 1996 .

[2]  Mario Grosso,et al.  Air and soil dioxin levels at three sites in Italy in proximity to MSW incineration plants. , 2004, Chemosphere.

[3]  M. Tysklind,et al.  PCDD and PCDF emissions from scrap metal melting processes at a steel mill , 1989 .

[4]  Perng-Jy Tsai,et al.  Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans from stack flue gases of sinter plants. , 2003, Chemosphere.

[5]  Kees Olie,et al.  Chlorodibenzo-p-dioxins and chlorodibenzofurans are trace components of fly ash and flue gas of some municipal incinerators in The Netherlands , 1977 .

[6]  J. Schaum,et al.  The Congener Profiles of Anthropogenic Sources of Chlorinated Dibenzo-p- Dioxins and Chlorinated Dibenzofurans in the United States , 1997 .

[7]  Erwin Cornelis,et al.  Fingerprints of dioxin from thermal industrial processes. , 2000, Chemosphere.

[8]  J. Jager PCDD/F and PCB emission from steel producing, processing and reclamation plants with varying input , 1993 .

[9]  Shui-Jen Chen,et al.  Characterizing polychlorinated dibenzo-p-dioxins and dibenzofurans in the surrounding environment and workplace of a secondary aluminum smelter , 2004 .

[10]  A. Buekens,et al.  On the mechanisms of dioxin formation in combustion processes , 1995 .

[11]  P. Tsai,et al.  Characterizing the emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans from crematories and their impacts to the surrounding environment. , 2003, Environmental science & technology.

[12]  J. Paasiv́irta,et al.  Formation of chloroaromatics at a metal reclamation plant and efficiency of stack filter in their removal from emission , 1996 .

[13]  P. Tsai,et al.  Emissions of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans from the Incinerations of Both Medical and Municipal Solid Wastes , 2003 .