Dear Editor, Despite the introduction of valved devices and tube ligation, ocular hypotony remains an important complication after tube surgery. When postoperative ocular hypotony occurs due to overdrainage through the tube, tube occlusion by ligation or stenting may be required. To perform the ab externo approach, the conjunctival wound should be reopened, and this may increase the risk of bleeding, fibrosis, or device exposure at the operation site. Thus, when conjunctival scarring is excessive or the conjunctiva is thin, the ab externo approach is limited. When tube length is suff icient to be extracted from the anterior chamber through the corneal incision, the anterior chamber-positioned part of the tube can be ligated and repositioned into the anterior chamber. However, ligation of the tube at a focal area may not induce sufficient and predictable outflow control [1]. Previous studies reported that intraluminal stenting produced effective and predictive outflow control [2-4]. Thus, ab interno tube stenting may be an effective method to manage postoperative ocular hypotony. We present a case of ocular hypotony after Ahmed glaucoma valve (AGV; New World Medical, Rancho Cucamonga, CA, USA) implantation that was resolved by stenting using two 5-0 nylon threads with an ab interno approach. A 50-year-old man with neovascular glaucoma underwent AGV implantation to control intraocular pressure (IOP). Despite previous trabeculectomy and maximal medical treatment, his IOP was greater than 35 mmHg. Intra-operatively, the superior-temporal conjunctiva was incised, and a body plate was placed approximately 12 mm posterior to the corneal limbus. The tube was ligated with 8-0 vicryl and entered into the anterior chamber. After AGV implantation, the IOP ranged from 7 to 10 mmHg without complications. However, two weeks after the surgery, IOP suddenly decreased to 2 mmHg, and the patient’s vision decreased from 20 / 400 to hand motion. The anterior chamber was shallow, and hypotony maculopathy was identified. Given that the ocular hypotony occurred 2 weeks postoperatively, excessive aqueous drainage through the tube due to loosening of tube ligation was suspected. To elevate IOP by intraluminal stenting with an ab interno approach, a corneal incision was made opposite the tube. A 5-0 nylon thread was inserted into the tube lumen using forceps (Fig. 1A). In the same manner, the second 5-0 nylon thread was inserted into the tube lumen (Fig. 1B). After making another corneal incision, the nylon threads were cut with scissors (Fig. 1C). To remove the thread, a small portion of it was left protruding from the tube tip (Fig. 1D). After this procedure, IOP was 8, 7, 14, and 29 mmHg at 1, 3, 5, and 10 days, respectively. Timolol/dorzolamide fixed-combination eye drops were applied twice daily, and IOP decreased to 10 mmHg. Both threads were removed 30 days after stenting by retraction. The IOP ranged from 10 to 13 mmHg without IOP-lowering medication for 6 months after this procedure, and vision recovered to 20 / 400. Korean J Ophthalmol 2018;32(6):523-524 ht tps: / /doi.org /10.3341/k jo.2018.0092
[1]
K. Moussa,et al.
Ab Interno Tube Occlusion for Postoperative Hypotony in a Patient With an Ahmed Glaucoma Drainage Device
,
2018,
Journal of glaucoma.
[2]
Y. Hwang,et al.
Implantation of a Modified Baerveldt Glaucoma Implant with a Smaller Tube and Intraluminal Stent
,
2017,
Korean journal of ophthalmology : KJO.
[3]
Y. Hwang,et al.
Novel membrane‐tube type glaucoma shunt device for glaucoma surgery
,
2016,
Clinical & experimental ophthalmology.
[4]
Y. Hwang,et al.
Membrane-tube-type glaucoma shunt device for refractory glaucoma surgery
,
2016,
Graefe's Archive for Clinical and Experimental Ophthalmology.
[5]
A. J. van der Veen,et al.
Postoperative Pressure Regulation in Glaucoma Shunt Surgery: Focal Tube Constriction is Not the Answer
,
2004,