Robust Energy-Constrained Frequency Reserves From Aggregations of Commercial Buildings

It has been shown that the heating, ventilation, and air conditioning (HVAC) systems of commercial buildings can offer ancillary services to power systems without loss of comfort. In this paper, we propose a new control framework for reliable scheduling and provision of frequency reserves by aggregations of commercial buildings. The framework incorporates energy-constrained frequency signals, which are adopted by several transmission system operators for loads and storage devices. We use a hierarchical approach with three levels: 1) reserve capacities are allocated among buildings (e.g., on a daily basis) using techniques from robust optimization; 2) a robust model predictive controller optimizes the HVAC system consumption typically every 30 minutes; and 3) a feedback controller adjusts the consumption to provide reserves in real time. We demonstrate how the framework can be used to estimate the reserve capacities in simulations with typical Swiss office buildings and different reserve product characteristics. Our results show that an aggregation of approximately 100 buildings suffices to meet the 5-MW minimum bid size of the Swiss reserve market.

[1]  Johan Löfberg,et al.  Automatic robust convex programming , 2012, Optim. Methods Softw..

[2]  Sean P. Meyn,et al.  Low-frequency power-grid ancillary services from commercial building HVAC systems , 2013, 2013 IEEE International Conference on Smart Grid Communications (SmartGridComm).

[3]  Goran Andersson,et al.  Integrating large shares of heterogeneous thermal loads in power system frequency control , 2015, 2015 IEEE Eindhoven PowerTech.

[4]  Dimitrios Gyalistras,et al.  Intermediate complexity model for Model Predictive Control of Integrated Room Automation , 2013 .

[5]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[6]  Manfred Morari,et al.  Model Predictive Control of a Swiss Office Building , 2013 .

[7]  Duncan S. Callaway,et al.  State Estimation and Control of Electric Loads to Manage Real-Time Energy Imbalance , 2013, IEEE Transactions on Power Systems.

[8]  H. Hindi,et al.  Coordinating regulation and demand response in electric power grids using multirate model predictive control , 2011, ISGT 2011.

[9]  Eric C. Kerrigan,et al.  Optimization over state feedback policies for robust control with constraints , 2006, Autom..

[10]  Fred Schweppe,et al.  Homeostatic Utility Control , 1980, IEEE Transactions on Power Apparatus and Systems.

[11]  Johanna L. Mathieu,et al.  Control of thermostatic loads using moving horizon estimation of individual load states , 2014, 2014 Power Systems Computation Conference.

[12]  James L. Kirtley,et al.  Energy storage for use in load frequency control , 2010, 2010 IEEE Conference on Innovative Technologies for an Efficient and Reliable Electricity Supply.

[13]  Alberto Bemporad,et al.  Robust model predictive control: A survey , 1998, Robustness in Identification and Control.

[14]  Sila Kiliccote,et al.  Field Testing of Automated Demand Response for Integration of Renewable Resources in California's Ancillary Services Market for Regulation Products , 2013 .

[15]  Manfred Morari,et al.  Reducing peak electricity demand in building climate control using real-time pricing and model predictive control , 2010, 49th IEEE Conference on Decision and Control (CDC).

[16]  M. M. Gouda,et al.  Building thermal model reduction using nonlinear constrained optimization , 2002 .

[17]  Sean P. Meyn,et al.  Ancillary service for the grid via control of commercial building HVAC systems , 2013, 2013 American Control Conference.

[18]  Sean P. Meyn,et al.  How demand response from commercial buildings will provide the regulation needs of the grid , 2012, 2012 50th Annual Allerton Conference on Communication, Control, and Computing (Allerton).

[19]  Pengwei Du,et al.  Sizing Energy Storage to Accommodate High Penetration of Variable Energy Resources , 2012, IEEE Transactions on Sustainable Energy.

[20]  Shuai Lu,et al.  Development and Validation of Aggregated Models for Thermostatic Controlled Loads with Demand Response , 2012, 2012 45th Hawaii International Conference on System Sciences.

[21]  John Lygeros,et al.  Selling robustness margins: A framework for optimizing reserve capacities for linear systems , 2014, 53rd IEEE Conference on Decision and Control.

[22]  Eisuke Shimoda,et al.  Fundamental study on controllability of heat pump power consumption for fluctuated power compensation , 2011, 2011 International Conference on Clean Electrical Power (ICCEP).

[23]  Evangelos Vrettos,et al.  Load frequency control by aggregations of thermally stratified electric water heaters , 2012, 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe).

[24]  Goran Andersson,et al.  Redesign of the automatic generation control scheme in the Swiss power system , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[25]  J. A. Crabb,et al.  A simplified thermal response model , 1987 .

[27]  Evangelos Vrettos,et al.  Robust Provision of Frequency Reserves by Office Building Aggregations , 2014 .

[28]  Evangelos Vrettos,et al.  Predictive Control of buildings for Demand Response with dynamic day-ahead and real-time prices , 2013, 2013 European Control Conference (ECC).

[29]  Ian A. Hiskens,et al.  Achieving Controllability of Electric Loads , 2011, Proceedings of the IEEE.

[30]  Scott Backhaus,et al.  Model Development and Identification for Fast Demand Response in Commercial HVAC Systems , 2014, IEEE Transactions on Smart Grid.

[31]  G. Mustafaraj,et al.  Development of room temperature and relative humidity linear parametric models for an open office using BMS data , 2010 .

[32]  Marko Bacic,et al.  Model predictive control , 2003 .

[33]  Moncef Krarti,et al.  Development of a Predictive Optimal Controller for Thermal Energy Storage Systems , 1997 .

[34]  Alberto L. Sangiovanni-Vincentelli,et al.  Model Predictive Control of regulation services from commercial buildings to the smart grid , 2014, 2014 American Control Conference.

[35]  Stephen P. Boyd,et al.  Convex Optimization , 2004, Algorithms and Theory of Computation Handbook.

[36]  Ernesto Kofman,et al.  Load management: Model-based control of aggregate power for populations of thermostatically controlled loads , 2012 .

[37]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[38]  Rp Rick Kramer,et al.  Simplified thermal and hygric building models: A literature review , 2012 .

[39]  Michael Wetter,et al.  Responsive and Intelligent Building Information and Control for Low-Energy and Optimized Grid Integration , 2012 .

[40]  Manfred Morari,et al.  Scenario-based MPC for energy-efficient building climate control under weather and occupancy uncertainty , 2013, 2013 European Control Conference (ECC).

[41]  J. Braun,et al.  Experimental and simulated performance of optimal control of building thermal storage , 1994 .

[42]  Philip Haves,et al.  Model predictive control for the operation of building cooling systems , 2010, Proceedings of the 2010 American Control Conference.

[43]  Alberto L. Sangiovanni-Vincentelli,et al.  Building Efficiency and Sustainability in the Tropics ( SinBerBEST ) Title Model Predictive Control Approach to Online Computation of Demand-Side Flexibility of Commercial Buildings HVAC Systems for Supply Following Permalink , 2014 .

[44]  James E. Braun,et al.  Reducing energy costs and peak electrical demand through optimal control of building thermal storage , 1990 .

[45]  Jian Ma,et al.  Operational Impacts of Wind Generation on California Power Systems , 2009, IEEE Transactions on Power Systems.

[46]  Sean P. Meyn,et al.  Experimental Evaluation of Frequency Regulation From Commercial Building HVAC Systems , 2015, IEEE Transactions on Smart Grid.

[47]  Ana Busic,et al.  Spectral Decomposition of Demand-Side Flexibility for Reliable Ancillary Services in a Smart Grid , 2015, 2015 48th Hawaii International Conference on System Sciences.

[48]  Young-Jin Kim,et al.  Variable speed heat pump design for frequency regulation through direct load control , 2014, 2014 IEEE PES T&D Conference and Exposition.

[49]  Scott Backhaus,et al.  Round-trip efficiency of fast demand response in a large commercial air conditioner , 2015 .

[50]  Johanna L. Mathieu,et al.  A framework for and assessment of demand response and energy storage in power systems , 2013, 2013 IREP Symposium Bulk Power System Dynamics and Control - IX Optimization, Security and Control of the Emerging Power Grid.

[51]  J. Braun,et al.  A Comparison of Chiller-Priority, Stprage-Priority, and Optumal Contorol of an Ice-Storage System , 1992 .

[52]  J. Braun,et al.  Load Control Using Building Thermal Mass , 2003 .

[53]  C. N. Jones,et al.  Use of Weather and Occupancy Forecasts for Optimal Building Climate Control (OptiControl) , 2009 .

[54]  Frauke Oldewurtel,et al.  Stochastic model predictive control for energy efficient building climate control , 2011 .