Synthetic double sampling s chart

ABSTRACT This study proposes a synthetic double sampling s chart that integrates the double sampling (DS) s chart and the conforming run length chart. An optimization procedure is proposed to compute the optimal parameters of the synthetic DS s chart. The performance of the synthetic DS s chart is compared with other existing control charts for monitoring process standard deviation. The results show that the synthetic DS s chart is more effective for detecting increases in the process standard deviation for a wide range of shifts. An example is provided to illustrate the operation procedure of the synthetic DS s chart.

[1]  Alireza Faraz,et al.  Optimal T2 Control Chart with a Double Sampling Scheme – An Alternative to the MEWMA Chart , 2012, Qual. Reliab. Eng. Int..

[2]  D. He,et al.  Multivariate multiple sampling charts , 2005 .

[3]  Michael B. C. Khoo,et al.  Economic and economic statistical designs of the synthetic chart using loss functions , 2013, Eur. J. Oper. Res..

[4]  Philippe Castagliola,et al.  Optimal design of the double sampling X chart with estimated parameters based on median run length , 2014, Comput. Ind. Eng..

[5]  Jean-Jacques Daudin,et al.  Double sampling X charts , 1992 .

[6]  Patrick D. Bourke,et al.  Detecting a shift in fraction nonconforming using runlength control charts with 100% inspection , 1991 .

[7]  Philippe Castagliola,et al.  Economically Optimum Design of a Synthetic X¯ Chart , 2012, Qual. Reliab. Eng. Int..

[8]  Antonio Costa,et al.  Constrained economic design of S control charts for random process shifts , 2011 .

[9]  Eugenio K. Epprecht,et al.  Th e Non-Central Chi-Square Chart with Double Sampling , 2010 .

[10]  Pei-Hsi Lee,et al.  Non-normality and combined double sampling and variable sampling interval control charts , 2010 .

[11]  Fang Yen Yen,et al.  Synthetic-Type Control Charts for Time-Between-Events Monitoring , 2013, PloS one.

[12]  D. T. Shirke,et al.  Nonparametric Synthetic Control Charts for Process Variation , 2012, Qual. Reliab. Eng. Int..

[13]  Yi-Chia Chang,et al.  A Design of s Control Charts with a Combined Double Sampling and Variable Sampling Interval Scheme , 2012 .

[14]  Philippe Castagliola,et al.  Synthetic double sampling np control chart for attributes , 2014, Comput. Ind. Eng..

[15]  Philippe Castagliola,et al.  Optimal design of the synthetic chart for the process mean based on median run length , 2012 .

[16]  David He,et al.  Joint statistical design of double sampling X and s charts , 2006, Eur. J. Oper. Res..

[17]  Joseph J. Pignatiello,et al.  ARL-Design of S Charts with k-of-k Runs Rules , 2009, Commun. Stat. Simul. Comput..

[18]  Eugenio K. Epprecht,et al.  Monitoring the process mean and variance using a synthetic control chart with two-stage testing , 2009 .

[19]  Antonio Fernando Branco Costa,et al.  Double sampling $$\overline{X} $$ control chart for a first-order autoregressive moving average process model , 2008 .

[20]  Philippe Castagliola,et al.  A Synthetic Scaled Weighted Variance Control Chart for Monitoring the Process Mean of Skewed Populations , 2009, Commun. Stat. Simul. Comput..

[21]  Philippe Castagliola,et al.  A multivariate synthetic double sampling T2 control chart , 2013, Comput. Ind. Eng..

[22]  Athanasios C. Rakitzis,et al.  Control charts with switching and sensitizing runs rules for monitoring process variation , 2014 .

[23]  Ming Ha Lee,et al.  The Design of the Multivariate Synthetic Exponentially Weighted Moving Average Control Chart , 2012, Commun. Stat. Simul. Comput..

[24]  Antonio Fernando Branco Costa,et al.  A side-sensitive synthetic chart combined with an X chart , 2014 .

[25]  Antonio Fernando Branco Costa,et al.  Variable parameter and double sampling charts in the presence of correlation: The Markov chain approach , 2011 .

[26]  Saddam Akber Abbasi,et al.  On median control charting under double sampling scheme , 2014 .

[27]  D. T. Shirke,et al.  A Nonparametric Synthetic Control Chart Using Sign Statistic , 2010 .

[28]  Maria E. Calzada,et al.  The Synthetic t and Synthetic EWMA t Charts , 2013 .

[29]  Pei-Hsi Lee,et al.  The Performance of Double Sampling Control Charts Under Non Normality , 2009, Commun. Stat. Simul. Comput..

[30]  David He,et al.  Construction of double sampling s‐control charts for agile manufacturing , 2002 .

[31]  J. M. Jabaloyes,et al.  Combined double sampling and variable sampling interval X chart , 2002 .

[32]  Pei-Hsi Lee,et al.  Design of adaptive s control charts , 2013 .

[33]  Michael B. C. Khoo,et al.  The effects of parameter estimation on minimising the in-control average sample size for the double sampling X chart , 2013 .

[34]  Saddam Akber Abbasi,et al.  MDEWMA chart: an efficient and robust alternative to monitor process dispersion , 2013 .

[35]  Antonio Fernando Branco Costa,et al.  The double sampling and the EWMA charts based on the sample variances , 2008 .

[36]  Philippe Castagliola,et al.  The synthetic [Xbar] chart with estimated parameters , 2011 .

[37]  D. Hey,et al.  Design of double-and triple-sampling X-bar control charts using genetic algorithms , 2002 .

[38]  Pei-Hsi Lee Joint statistical design of x and s charts with combined double sampling and variable sampling interval , 2013, Eur. J. Oper. Res..

[39]  Francisco Aparisi,et al.  The Design and Performance of the Multivariate Synthetic-T 2 Control Chart , 2009 .

[40]  Francisco Aparisi,et al.  Double sampling hotelling's T2 charts , 2008, Qual. Reliab. Eng. Int..

[41]  Michael B. C. Khoo,et al.  Optimal Designs of the Median Run Length Based Double Sampling X̄ Chart for Minimizing the Average Sample Size , 2013, PloS one.

[42]  S. Sheu,et al.  The Generally Weighted Moving Average Variance Chart , 2013 .

[43]  Philippe Castagliola,et al.  Optimal designs of the multivariate synthetic chart for monitoring the process mean vector based on median run length , 2011, Qual. Reliab. Eng. Int..

[44]  Pei-Hsi Lee,et al.  An economic design of double sampling X charts for correlated data using genetic algorithms , 2009, Expert Syst. Appl..

[45]  Philippe Castagliola,et al.  Optimal designs of the double sampling X¯ chart with estimated parameters , 2013 .

[46]  H. D.,et al.  An improved double sampling s chart , 2003 .

[47]  Philippe Castagliola,et al.  A synthetic double sampling control chart for the process mean , 2010 .

[48]  Trevor A Spedding,et al.  A Synthetic Control Chart for Detecting Small Shifts in the Process Mean , 2000 .

[49]  Antonio Fernando Branco Costa,et al.  The synthetic control chart based on two sample variances for monitoring the covariance matrix , 2009, Qual. Reliab. Eng. Int..

[50]  D. T. Shirke,et al.  A Nonparametric Shewhart-Type Synthetic Control Chart , 2010, Commun. Stat. Simul. Comput..

[51]  Pei-Hsi Lee,et al.  An economic-statistical design of double sampling control chart , 2009 .

[52]  Michael B. C. Khoo,et al.  The Synthetic Mean Square Error Control Chart , 2014, Commun. Stat. Simul. Comput..

[53]  Antonio F. B. Costa,et al.  Some Comments Regarding the Synthetic Chart , 2014 .

[54]  H. J. Huang,et al.  A synthetic control chart for monitoring process dispersion with sample standard deviation , 2005, Comput. Ind. Eng..

[55]  William H. Woodall,et al.  Evaluating and Improving the Synthetic Control Chart , 2002 .

[56]  Michael B. C. Khoo,et al.  Multivariate Synthetic |S| Control Chart with Variable Sampling Interval , 2015, Commun. Stat. Simul. Comput..

[57]  D. T. Shirke,et al.  A Multivariate Synthetic Control Chart for Process Dispersion , 2008 .

[58]  Philippe Castagliola,et al.  Development of a multiattribute synthetic-np chart , 2014 .

[59]  Philippe Castagliola,et al.  Synthetic Phase II Shewhart‐type Attributes Control Charts When Process Parameters are Estimated , 2014, Qual. Reliab. Eng. Int..

[60]  Maysa S. de Magalhães,et al.  Double-sampling control charts for attributes , 2011 .

[61]  Michael B. C. Khoo,et al.  Economically Optimal Design of a Multivariate Synthetic T 2 Chart , 2014, Commun. Stat. Simul. Comput..

[62]  Pei-Hsi Lee,et al.  An economic design of combined double sampling and variable sampling interval X¯ control chart , 2012 .

[63]  Zhang Wu,et al.  A combined synthetic and np scheme for detecting increases in fraction nonconforming , 2012, Comput. Ind. Eng..

[64]  V. B. Ghute,et al.  A Synthetic Control Chart for Monitoring Process Variability , 2014, Qual. Reliab. Eng. Int..

[65]  Min Xie,et al.  An Optimal Control Procedure based on Multivariate Synthetic Cumulative Sum , 2014, Qual. Reliab. Eng. Int..

[66]  Lie-Fern Hsu Note on 'Construction of Double Sampling s-Control Charts for Agile Manufacturing' , 2007, Qual. Reliab. Eng. Int..

[67]  Antonio Fernando Branco Costa,et al.  Bivariate control charts with double sampling , 2008 .

[68]  Philippe Castagliola,et al.  A combined synthetic&X chart for monitoring the process mean , 2010 .

[69]  David He,et al.  Design of double- and triple-sampling X-bar control charts using genetic algorithms , 2002 .

[70]  Lie-Fern Hsu Note on ‘Design of double- and triple-sampling X-bar control charts using genetic algorithms’ , 2004 .

[71]  Guoyi Zhang,et al.  Improved R and s control charts for monitoring the process variance , 2014 .

[72]  Athanasios C. Rakitzis,et al.  On the improvement of one-sided S control charts , 2011 .

[73]  Toni Lupo,et al.  An Effective Double Sampling Scheme for the c Control Chart , 2015, Qual. Reliab. Eng. Int..

[74]  Seyed Taghi Akhavan Niaki,et al.  Multiobjective design of an S control chart for monitoring process variability , 2012 .

[75]  Abdul Haq,et al.  An improved mean deviation exponentially weighted moving average control chart to monitor process dispersion under ranked set sampling , 2014 .

[76]  Antonio Fernando Branco Costa,et al.  The steady‐state behavior of the synthetic and side‐sensitive synthetic double sampling X¯ charts , 2015, Qual. Reliab. Eng. Int..

[77]  Saddam Akber Abbasi,et al.  On monitoring process variability under double sampling scheme , 2013 .

[78]  Maria E. Calzada,et al.  A synthetic control chart for the coefficient of variation , 2013 .