Influence of dilated cardiomyopathy and a left ventricular assist device on vortex dynamics in the left ventricle

Together with new developments in mechanical cardiac support, the analysis of vortex dynamics in the left ventricle has become an increasingly important topic in literature. The aim of this study was to develop a method to investigate the influence of a left ventricular assist device (LVAD) on vortex dynamics in a failing ventricle. An axisymmetric fluid dynamics model of the left ventricle was developed and coupled to a lumped parameter model of the complete circulation. Simulations were performed for healthy conditions and dilated cardiomyopathy (DCM). Vortex structures in these simulations were analysed by means of automated detection. Results show that the strength of the leading vortex ring is lower in a DCM ventricle than in a healthy ventricle. The LVAD further influences the maximum strength of the vortex and also causes the vortex to disappear earlier in time with increasing LVAD flows. Understanding these phenomena by means of the method proposed in this study will contribute to enhanced diagnostics and monitoring during cardiac support.

[1]  J. Stijnen Interaction between the mitral and aortic heart valve : an experimental and computational study , 2004 .

[2]  Shigeo Wada,et al.  Influence of the Opening Mode of the Mitral Valve Orifice on Intraventricular Hemodynamics , 2006, Annals of Biomedical Engineering.

[3]  A. D. Gosman,et al.  Computational Flow Modeling of the Left Ventricle Based on In Vivo MRI Data: Initial Experience , 2001, Annals of Biomedical Engineering.

[4]  Mario J. Garcia,et al.  New Doppler echocardiographic applications for the study of diastolic function. , 1998, Journal of the American College of Cardiology.

[5]  R Hetzer,et al.  Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device. , 1999, The Annals of thoracic surgery.

[6]  Mario J. Garcia,et al.  Estimation of diastolic intraventricular pressure gradients by Doppler M-mode echocardiography. , 2001, American journal of physiology. Heart and circulatory physiology.

[7]  L. Franca,et al.  Stabilized finite element methods. II: The incompressible Navier-Stokes equations , 1992 .

[8]  Olga Pierrakos,et al.  The effect of vortex formation on left ventricular filling and mitral valve efficiency. , 2006, Journal of biomechanical engineering.

[9]  Toshiaki Hisada,et al.  Multiphysics simulation of left ventricular filling dynamics using fluid-structure interaction finite element method. , 2004, Biophysical journal.

[10]  Iwao Yamaguchi,et al.  The Wake of a Large Vortex Is Associated with Intraventricular Filling Delay in Impaired Left Ventricles with a Pseudonormalized Transmitral Flow Pattern , 2006, Echocardiography.

[11]  H. Scheld,et al.  Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. , 2004, The Annals of thoracic surgery.

[12]  P. Vandervoort,et al.  Colour M‐mode velocity propagation: a glance at intra‐ventricular pressure gradients and early diastolic ventricular performance , 2005, European journal of heart failure.

[13]  F. Prinzen,et al.  Relation between left ventricular cavity pressure and volume and systolic fiber stress and strain in the wall. , 1991, Biophysical journal.

[14]  Gianfranco Ferrari,et al.  Computer simulation of haemodynamic parameters changes with left ventricle assist device and mechanical ventilation , 2000, Comput. Biol. Medicine.

[15]  A P Yoganathan,et al.  Left ventricular blood flow patterns in normal subjects: a quantitative analysis by three-dimensional magnetic resonance velocity mapping. , 1995, Journal of the American College of Cardiology.

[16]  J. De Sutter,et al.  Diastolic filling and pressure imaging: taking advantage of the information in a colour M-mode Doppler image. , 2001, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[17]  Pascal Verdonck,et al.  Unloading effect of a rotary blood pump assessed by mathematical modeling. , 2003, Artificial organs.

[18]  A Kitabatake,et al.  Computational study on the evolution of an intraventricular vortical flow during early diastole for the interpretation of color M-mode Doppler echocardiograms , 2003, Biomechanics and modeling in mechanobiology.

[19]  Guang-Zhong Yang,et al.  Progress Towards Patient-Specific Computational Flow Modeling of the Left Heart via Combination of Magnetic Resonance Imaging with Computational Fluid Dynamics , 2004, Annals of Biomedical Engineering.

[20]  D. Burkhoff,et al.  Comparison of Right and Left Ventricular Responses to Left Ventricular Assist Device Support in Patients With Severe Heart Failure: A Primary Role of Mechanical Unloading Underlying Reverse Remodeling , 2001, Circulation.

[21]  Jean Hertzberg,et al.  Characterizing Vortex Ring Behavior During Ventricular Filling with Doppler Echocardiography: An in Vitro Study , 2004, Annals of Biomedical Engineering.

[22]  T. Myers,et al.  Left ventricular assist system as a bridge to myocardial recovery. , 1999, The Annals of thoracic surgery.

[23]  H. Suga,et al.  Instantaneous Pressure‐Volume Relationships and Their Ratio in the Excised, Supported Canine Left Ventricle , 1974, Circulation research.

[24]  E L Yellin,et al.  Left ventricular filling dynamics and diastolic function. , 1990, Progress in cardiovascular diseases.

[25]  P. Verdonck,et al.  Computer simulation of intraventricular flow and pressure gradients during diastole. , 2000, Journal of biomechanical engineering.

[26]  O. Frazier,et al.  Improved left ventricular function after chronic left ventricular unloading. , 1996, The Annals of thoracic surgery.

[27]  Jinhee Jeong,et al.  On the identification of a vortex , 1995, Journal of Fluid Mechanics.

[28]  R. Anderson,et al.  The Deformational Characteristics of the Left Ventricle in the Conscious Dog , 1981, Circulation research.

[29]  Pascal Verdonck,et al.  Modeling Ventricular Function during Cardiac Assist: Does Time-Varying Elastance Work? , 2006, ASAIO journal.

[30]  J Strackee,et al.  Determinants of the occurrence of vortex rings in the left ventricle during diastole. , 1990, Journal of biomechanics.

[31]  Gianni Pedrizzetti,et al.  Model and influence of mitral valve opening during the left ventricular filling. , 2003, Journal of biomechanics.

[32]  Patrick Segers,et al.  Effect of rotary blood pump failure on left ventricular energetics assessed by mathematical modeling. , 2002, Artificial organs.

[33]  F. N. van de Vosse,et al.  Dependence of Intramyocardial Pressure and Coronary Flow on Ventricular Loading and Contractility: A Model Study , 2006, Annals of Biomedical Engineering.

[34]  Gianni Pedrizzetti,et al.  Fluid dynamics of the left ventricular filling in dilated cardiomyopathy. , 2002, Journal of biomechanics.

[35]  D. Burkhoff,et al.  Comparison of Right and Left Ventricular Responses to Left Ventricular Assist Device Support in Patients With Severe Heart Failure: A Primary Role of Mechanical Unloading Underlying Reverse Remodeling , 2001, Circulation.

[36]  Roy C. P. Kerckhoffs,et al.  Intra- and interventricular asynchrony of electromechanics in the ventricularly paced heart , 2003 .

[37]  F. N. van de Vosse,et al.  Finite-element-based computational methods for cardiovascular fluid-structure interaction , 2003 .

[38]  Stephen Westaby,et al.  Initial Clinical Experience With the Jarvik 2000 Implantable Axial-Flow Left Ventricular Assist System , 2002, Circulation.

[39]  Marcel C M Rutten,et al.  A mathematical model to evaluate control strategies for mechanical circulatory support. , 2009, Artificial organs.

[40]  V. Fuster Hurst's the Heart , 1966 .