A Survey on Sensor Calibration in Air Pollution Monitoring Deployments

Air pollution is a major concern for public health and urban environments. Conventional air pollution monitoring systems install a few highly accurate, expensive stations at representative locations. Their sparse coverage and low spatial resolution are insufficient to quantify urban air pollution and its impacts on human health and environment. Advances in low-cost portable air pollution sensors have enabled air pollution monitoring deployments at scale to measure air pollution at high spatiotemporal resolution. However, it is challenging to ensure the accuracy of these low-cost sensor deployments because the sensors are more error-prone than high-end sensing infrastructures and they are often deployed in harsh environments. Sensor calibration has proven to be effective to improve the data quality of low-cost sensors and maintain the reliability of long-term, distributed sensor deployments. In this paper, we review the state-of-the-art low-cost air pollution sensors, identify their major error sources, and comprehensively survey calibration models as well as network recalibration strategies suited for different sensor deployments. We also discuss limitations of exiting methods and conclude with open issues for future sensor calibration research.

[1]  G. Hagler,et al.  Community Air Sensor Network (CAIRSENSE) project: evaluation of low-cost sensor performance in a suburban environment in the southeastern United States. , 2016, Atmospheric measurement techniques.

[2]  Ali Marjovi,et al.  Enhancing measurement quality through active sampling in mobile air quality monitoring sensor networks , 2016, 2016 IEEE International Conference on Advanced Intelligent Mechatronics (AIM).

[3]  Elena Esposito,et al.  Calibrating chemical multisensory devices for real world applications: An in-depth comparison of quantitative Machine Learning approaches , 2017, ArXiv.

[4]  Eric Paulos,et al.  MyPart: Personal, Portable, Accurate, Airborne Particle Counting , 2016, CHI.

[5]  D. Worsnop,et al.  Use of electrochemical sensors for measurement of air pollution: correcting interference response and validating measurements , 2017 .

[6]  Li Shang,et al.  Collaborative calibration and sensor placement for mobile sensor networks , 2012, 2012 ACM/IEEE 11th International Conference on Information Processing in Sensor Networks (IPSN).

[7]  John Saffell,et al.  Amperometric Gas Sensors as a Low Cost Emerging Technology Platform for Air Quality Monitoring Applications: A Review. , 2017, ACS sensors.

[8]  C. Pijolat,et al.  Calibration of a multivariate gas sensing device for atmospheric pollution measurement , 2006 .

[9]  Grazia Fattoruso,et al.  Stochastic Comparison of Machine Learning Approaches to Calibration of Mobile Air Quality Monitors , 2016, Sensors.

[10]  Matthias Budde,et al.  Enabling low-cost particulate matter measurement for participatory sensing scenarios , 2013, MUM.

[11]  S. D. Vito,et al.  CO, NO2 and NOx urban pollution monitoring with on-field calibrated electronic nose by automatic bayesian regularization , 2009 .

[12]  Yang Wang,et al.  Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement , 2015 .

[13]  Grazia Fattoruso,et al.  Computational Intelligence for Smart Air Quality Monitors Calibration , 2017, ICCSA.

[14]  E. Massera,et al.  On field calibration of an electronic nose for benzene estimation in an urban pollution monitoring scenario , 2008 .

[15]  Dong Xiang,et al.  Metal Oxide Gas Sensors: Sensitivity and Influencing Factors , 2010, Sensors.

[16]  Ingemar Lundström,et al.  Artificial neural networks and gas sensor arrays: quantification of individual components in a gas mixture , 1991 .

[17]  Alastair C. Lewis,et al.  Electrochemical ozone sensors: A miniaturised alternative for ozone measurements in laboratory experiments and air-quality monitoring , 2017 .

[18]  Alankar Shrivastava,et al.  Methods for the determination of limit of detection and limit of quantitation of the analytical methods , 2011 .

[19]  H. Ulmer,et al.  Detection of human effluents by a MOS gas sensor in correlation to VOC quantification by GC/MS , 2010 .

[20]  Olalekan Popoola,et al.  Development of a baseline-temperature correction methodology for electrochemical sensors and its implications for long-term stability , 2016 .

[21]  D. Holstius,et al.  Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California , 2014 .

[22]  Li Sun,et al.  Development and Evaluation of A Novel and Cost-Effective Approach for Low-Cost NO2 Sensor Drift Correction , 2017, Sensors.

[23]  Marcel Bruins,et al.  Enabling a transferable calibration model for metal-oxide type electronic noses , 2013 .

[24]  H. Ishida,et al.  Gas sensor network for air-pollution monitoring , 2005 .

[25]  E. Seto,et al.  A distributed network of low-cost continuous reading sensors to measure spatiotemporal variations of PM2.5 in Xi'an, China. , 2015, Environmental pollution.

[26]  Mani B. Srivastava,et al.  Reputation-based framework for high integrity sensor networks , 2004, SASN '04.

[27]  Zhijun Li,et al.  AirCloud: a cloud-based air-quality monitoring system for everyone , 2014, SenSys.

[28]  David Zhang,et al.  Calibration transfer and drift compensation of e-noses via coupled task learning , 2016 .

[29]  George W. Kling,et al.  Performance of a low-cost methane sensor for ambient concentration measurements in preliminary studies , 2012 .

[30]  Matthieu Puigt,et al.  Nonlinear mobile sensor calibration using informed semi-nonnegative matrix factorization with a Vandermonde factor , 2016, 2016 IEEE Sensor Array and Multichannel Signal Processing Workshop (SAM).

[31]  Matthieu Puigt,et al.  Blind Calibration of Mobile Sensors Using Informed Nonnegative Matrix Factorization , 2015, LVA/ICA.

[32]  Alison S. Tomlin,et al.  Flow field measurements in the proximity of an urban intersection in London, UK , 2005 .

[33]  Rajib Bandyopadhyay,et al.  Calibration transfer between electronic nose systems for rapid in situ measurement of pulp and paper industry emissions. , 2014, Analytica chimica acta.

[34]  Carlo Ratti,et al.  End-user perspective of low-cost sensors for outdoor air pollution monitoring. , 2017, The Science of the total environment.

[35]  Laurent Spinelle,et al.  Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds , 2017, Sensors.

[36]  Lothar Thiele,et al.  Pre-Deployment Testing, Augmentation and Calibration of Cross-Sensitive Sensors , 2016, EWSN.

[37]  Gb Stewart,et al.  The use of electrochemical sensors for monitoring urban air quality in low-cost, high-density networks , 2013 .

[38]  L. Spinelle,et al.  Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring. Part B: NO, CO and CO2 , 2017 .

[39]  Anna Karion,et al.  Evaluation and environmental correction of ambient CO2 measurements from a low-cost NDIR sensor. , 2017, Atmospheric measurement techniques.

[40]  Iain Bate,et al.  Issues of using wireless sensor network to monitor urban air quality , 2017, FAILSAFE@SenSys.

[41]  Huazhong Yang,et al.  Blind Drift Calibration of Sensor Networks Using Sparse Bayesian Learning , 2016, IEEE Sensors Journal.

[42]  Alena Bartonova,et al.  Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates? , 2017, Environment international.

[43]  Jian Lu,et al.  SBC: scalable smartphone barometer calibration through crowdsourcing , 2014, MobiQuitous.

[44]  S. De Vito,et al.  Dynamic neural network architectures for on field stochastic calibration of indicative low cost air quality sensing systems , 2016 .

[45]  Lothar Thiele,et al.  On-the-Fly Calibration of Low-Cost Gas Sensors , 2012, EWSN.

[46]  Lothar Thiele,et al.  Reducing multi-hop calibration errors in large-scale mobile sensor networks , 2015, IPSN.

[47]  L. Spinelle,et al.  Sensors and Actuators B: Chemical Field calibration of a cluster of low-cost available sensors for air quality monitoring. Part A: Ozone and nitrogen dioxide (cid:2) , 2022 .

[48]  Jonathan E. Thompson,et al.  Crowd-sourced air quality studies: A review of the literature & portable sensors , 2016 .

[49]  L. Zeller,et al.  Characterisation of humidity dependence of a metal oxide semiconductor sensor array using partial least squares , 2008 .

[50]  A. Bartoňová,et al.  On the use of small and cheaper sensors and devices for indicative citizen-based monitoring of respirable particulate matter. , 2015, Environmental pollution.

[51]  Li Sun,et al.  Impact Analysis of Temperature and Humidity Conditions on Electrochemical Sensor Response in Ambient Air Quality Monitoring , 2018, Sensors.

[52]  David Zhang,et al.  Improving the transfer ability of prediction models for electronic noses , 2015 .

[53]  Ali Marjovi,et al.  Model-based rendezvous calibration of mobile sensor networks for monitoring air quality , 2015, 2015 IEEE SENSORS.

[54]  A. Lewis,et al.  Evaluating the performance of low cost chemical sensors for air pollution research. , 2016, Faraday discussions.

[55]  Valérie Issarny,et al.  Opportunistic Multiparty Calibration for Robust Participatory Sensing , 2017, 2017 IEEE 14th International Conference on Mobile Ad Hoc and Sensor Systems (MASS).

[56]  Lei Zhang,et al.  On-line sensor calibration transfer among electronic nose instruments for monitoring volatile organic chemicals in indoor air quality , 2011 .

[57]  Wei Dong,et al.  Multihop calibration for mobile sensing: K-hop Calibratability and reference sensor deployment , 2017, IEEE INFOCOM 2017 - IEEE Conference on Computer Communications.

[58]  Ali Marjovi,et al.  Mitigating Slow Dynamics of Low-Cost Chemical Sensors for Mobile Air Quality Monitoring Sensor Networks , 2016, EWSN.

[59]  R. Cattrall Chemical Sensors , 1997 .

[60]  Elena Austin,et al.  Laboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor , 2015, PloS one.

[61]  Michalis P. Michaelides,et al.  Air pollution monitoring in lemesos using a wireless sensor network , 2016, 2016 18th Mediterranean Electrotechnical Conference (MELECON).

[62]  David Zhang,et al.  A Transfer Learning Approach for Correcting Instrumental Variation and Time-Varying Drift , 2017 .

[63]  Rodrigo Roman,et al.  Trust management systems for wireless sensor networks: Best practices , 2010, Comput. Commun..

[64]  Matthias Budde,et al.  Privacy-Preserving Collaborative Blind Macro-Calibration of Environmental Sensors in Participatory Sensing , 2018, IoT 2018.

[65]  Lothar Thiele,et al.  SCAN: Multi-Hop Calibration for Mobile Sensor Arrays , 2017, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol..

[66]  Jonathan P. Franklin,et al.  Calibration and assessment of electrochemical air quality sensors by co-location with regulatory-grade instruments , 2017 .

[67]  Kwong-Sak Leung,et al.  A Survey of Wireless Sensor Network Based Air Pollution Monitoring Systems , 2015, Sensors.

[68]  Jeremy Colls,et al.  Air Pollution: Measurement, Modelling and Mitigation , 1997 .

[69]  Allen L. Robinson,et al.  A machine learning calibration model using random forests to improve sensor performance for lower-cost air quality monitoring , 2018 .

[70]  David M. Broday,et al.  Wireless Distributed Environmental Sensor Networks for Air Pollution Measurement—The Promise and the Current Reality , 2017, Sensors.

[71]  Alena Bartonova,et al.  Node-to-node field calibration of wireless distributed air pollution sensor network. , 2018, Environmental pollution.

[72]  Nadine Locoge,et al.  Development of a normalized multi-sensors system for low cost on-line atmospheric pollution detection , 2017 .

[73]  Messaoud Doudou,et al.  Calibrating low-cost air quality sensors using multiple arrays of sensors , 2018, 2018 IEEE Wireless Communications and Networking Conference (WCNC).

[74]  R. Piedrahita,et al.  Approach for quantification of metal oxide type semiconductor gas sensors used for ambient air quality monitoring , 2015 .

[75]  Matthieu Puigt,et al.  Blind mobile sensor calibration using an informed nonnegative matrix factorization with a relaxed rendezvous model , 2016, 2016 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[76]  S.Sumithra,et al.  Rendezvous Planning in Wireless Sensor Networks with Mobile Elements , 2015 .

[77]  Barak Fishbain,et al.  Self Calibrated Wireless Distributed Environmental Sensory Networks , 2016, Scientific Reports.

[78]  L. Shang,et al.  The next generation of low-cost personal air quality sensors for quantitative exposure monitoring , 2014 .

[79]  Lothar Thiele,et al.  Model-Driven Accuracy Bounds for Noisy Sensor Readings , 2013, 2013 IEEE International Conference on Distributed Computing in Sensor Systems.

[80]  Yoon-Hwa Choi,et al.  Neighbor-Based Malicious Node Detection in Wireless Sensor Networks , 2012 .

[81]  Jonas Meyer,et al.  Design of an ozone and nitrogen dioxide sensor unit and its long-term operation within a sensor network in the city of Zurich , 2017 .

[82]  Russell Binions,et al.  Metal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring , 2010, Sensors.

[83]  Tania Martellini,et al.  Indoor Air Quality and Health , 2017, International journal of environmental research and public health.

[84]  M. Carotta,et al.  Nanostructured thick-film gas sensors for atmospheric pollutant monitoring: quantitative analysis on field tests , 2001 .

[85]  Catherine Newman,et al.  The BErkeley Atmospheric CO 2 Observation Network: field calibration and evaluation of low-cost air quality sensors , 2017 .

[86]  Christian Monn,et al.  Exposure assessment of air pollutants: a review on spatial heterogeneity and indoor/outdoor/personal exposure to suspended particulate matter, nitrogen dioxide and ozone , 2001 .

[87]  Roman M. Balabin,et al.  Support vector machine regression (SVR/LS-SVM)--an alternative to neural networks (ANN) for analytical chemistry? Comparison of nonlinear methods on near infrared (NIR) spectroscopy data. , 2011, The Analyst.

[88]  Daqiang Zhang,et al.  A Survey on Gas Sensing Technology , 2012, Sensors.

[89]  L. Balzano,et al.  Blind Calibration of Sensor Networks , 2007, 2007 6th International Symposium on Information Processing in Sensor Networks.

[90]  Iain Bate,et al.  Using Multi-parameters for Calibration of Low-cost Sensors in Urban Environment , 2017, EWSN.

[91]  U. Lerner,et al.  On the feasibility of measuring urban air pollution by wireless distributed sensor networks. , 2015, The Science of the total environment.

[92]  James L. Repace,et al.  Determining PM2.5 calibration curves for a low-cost particle monitor: common indoor residential aerosols. , 2015, Environmental science. Processes & impacts.

[93]  J Janata Chemical sensors. , 1990, Analytical chemistry.

[94]  Lothar Thiele,et al.  W-Air , 2018, Proc. ACM Interact. Mob. Wearable Ubiquitous Technol..

[95]  R. Huerta,et al.  Calibration transfer and drift counteraction in chemical sensor arrays using Direct Standardization , 2016 .