Condensation risk due to variations in airtightness and thermal insulation of an office building in warm and wet climate

Condensation in a building encourages microbial growth, which can have an adverse effect on the health of occupants. Furthermore, it induces the deterioration of the building. To prevent problems caused by condensation, from the design step of a building, predictions of the spatial, temporal and causation for condensation occurrences are necessary. By using TRNSYS simulation coupled with TRNFLOW, condensation assessment of an entire office building in Tokyo, Japan, was conducted throughout the year, including when the air-conditioning system was not operated, by considering the absorption-desorption properties of the building materials and papers in the office and the airflow within the entire building. It was found that most of the condensation occurred during winter and was observed mainly in the non-air-conditioned core parts, especially the topmost floor. Additional analyses, which identified the effect of variations in the thermal insulation of the external walls, roof and windows and the airtightness of the windows on condensation, showed that the lower airtightness of windows resulted in decreased condensation risks, and condensation within the building was suppressed completely when the thermal insulation material thickness of the external walls was greater than 75 mm, that of the roof was greater than 105 mm and the windows had triple float glass.

[1]  R. Maus,et al.  Survival of bacterial and mold spores in air filter media , 2001 .

[2]  Jing Liu,et al.  CFD prediction of surface condensation on walls and its experimental validation , 2004 .

[3]  Cruz Alonso,et al.  Relative humidity in the interior of concrete exposed to natural and artificial weathering , 1999 .

[4]  M. Hamdan Layered wall design to prevent moisture condensation on its inside surface , 2002 .

[5]  Wong Nyuk Hien,et al.  Effects of double glazed facade on energy consumption, thermal comfort and condensation for a typical office building in Singapore , 2005 .

[6]  O. Valbjørn,et al.  Moulds and health - an epidemiological study , 2002 .

[7]  Daniel Aelenei,et al.  Analysis of the condensation risk on exterior surface of building envelopes , 2008 .

[8]  B. M. Small Creating Mold-Free Buildings: A Key to Avoiding Health Effects of Indoor Molds , 2003, Archives of environmental health.

[9]  池田 耕一 空調システムにおける微生物汚染の実態と対策に関する研究 : 第1報 微生物の生育環境と汚染実態 , 2005 .

[10]  Tadj Oreszczyn,et al.  Condensation risk: comparison of steady-state and transient methods , 2006 .

[11]  Monika Woloszyn,et al.  Impact of moisture buffering on energy performance of cooling ceilings , 2006 .

[12]  Rachel Becker Condensation and mould growth in dwellings—parametric and field study , 1984 .

[13]  Jim White,et al.  The Influence of House Characteristics in a Canadian Community on Microbiological Contamination , 1998 .

[14]  W. Fisk,et al.  Meta-analyses of the associations of respiratory health effects with dampness and mold in homes. , 2007, Indoor air.

[15]  Kambiz Vafai,et al.  Condensation Effects in a Fibrous Insulation Slab , 1986 .

[16]  A. Janssens,et al.  Interstitial Condensation Due to Air Leakage: A Sensitivity Analysis , 2003 .

[17]  Pertti Pasanen,et al.  Water Condensation Promotes Fungal Growth In Ventilation Ducts , 1993 .

[18]  K. Hasegawa,et al.  Moisture buffering and effect of ventilation rate and volume rate of hygrothermal materials in a single room under steady state exterior conditions , 2009 .

[19]  Tadj Oreszczyn,et al.  Condensation risk prediction: Addition of a condensation model to BREDEM , 1988 .

[20]  A Hedge,et al.  Sick building syndrome: a study of 4373 office workers. , 1987, The Annals of occupational hygiene.

[21]  Myoung-Souk Yeo,et al.  Evaluation of inside surface condensation in double glazing window system with insulation spacer: A case study of residential complex , 2007 .

[22]  G. S. Gutt Condensation in Attics: Are vapor barriers really the answer? , 1979 .

[23]  T. Kusuda,et al.  EARTH TEMPERATURE AND THERMAL DIFFUSIVITY AT SELECTED STATIONS IN THE UNITED STATES , 1965 .

[24]  C. L. Tien,et al.  Analysis of condensation in porous insulation , 1981 .

[25]  O Seppänen,et al.  Risk factors in heating, ventilating, and air-conditioning systems for occupant symptoms in US office buildings: the US EPA BASE study. , 2008, Indoor air.

[26]  Jon Winkler,et al.  Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings , 2013 .

[27]  Rachel Becker Effects of heating patterns on internal surface temperatures and risk of condensation , 1993 .

[28]  Stanley A. Mumma,et al.  Chilled Ceilings in Parallel with Dedicated Outdoor Air Systems: Addressing the Concerns of Condensation, Capacity, and Cost , 2002 .

[29]  Tariq Muneer,et al.  Frequency of condensation occurrence on double-glazing in the United Kingdom , 1998 .

[30]  Takao Sawachi,et al.  Integration model of hygrothermal analysis with decay process for durability assessment of building envelopes , 2012, Building Simulation.

[31]  Fu Xiao,et al.  Neural network based prediction method for preventing condensation in chilled ceiling systems , 2012 .

[32]  Andrew Saxon,et al.  The medical effects of mold exposure. , 2006, The Journal of allergy and clinical immunology.

[33]  Nathan Mendes,et al.  A Comparison Exercise for Calculating Heat and Moisture Transfers using TRNSYS and PowerDomus , 2005 .