An RF Stethoscope with Digital SSB Frequency Modulation for Use in a Noisy Environment

A 24 GHz Doppler radar based stethoscope has been modified for non-contact diagnosis of heart sounds in a high-noise environment. By adding a digital single-sideband (SSB) modulator, the very low-frequency and difficult to hear heart sounds detected by this stethoscope were shifted toward the more sensitive part of the human ear’s frequency response.In a quiet environment, the heart sounds heard by the modified radio frequency (RF) stethoscope are shown to be the same as those heard by a conventional stethoscope. However, the modified RF stethoscope has an advantage in an extremely high noise environment, where a conventional stethoscope cannot be used. Under those conditions, the quality of the RF stethoscope’s acoustic response is shown to remain substantially unchanged.

[1]  Miguel Tavares Coimbra,et al.  A comparative study of electronic stethoscopes for cardiac auscultation , 2017, 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[2]  Scott Wardle A Hilbert-Transformer Frequency Shifter for Audio , 2008 .

[3]  M. Borne,et al.  Auscultation in flight: comparison of conventional and electronic stethoscopes. , 2011, Air medical journal.

[4]  Changzhi Li,et al.  Null point elimination using RF phase shifter in continuous-wave Doppler radar system , 2011 .

[5]  Yi-Chyun Chiang,et al.  Null point elimination using biphase states in a direct conversion vital signal detection radar , 2014, 2014 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-Bio2014).

[6]  Rajesh Rajamani,et al.  Noise control challenges for auscultation on medical evacuation helicopters , 2014 .

[7]  Robert Weigel,et al.  Radar-Based Heart Sound Detection , 2018, Scientific Reports.

[8]  Yao Lu,et al.  Heart sounds monitor and analysis in noisy environments , 2012, 2012 International Conference on Systems and Informatics (ICSAI2012).

[9]  Changzhi Li,et al.  A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[10]  Olga Boric-Lubecke,et al.  Amplitude modulation issues in Doppler radar heart signal extraction , 2011, 2011 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems.

[11]  Steven J Gaydos,et al.  Clinical Assessment of the Noise Immune Stethoscope aboard a U.S. Navy Carrier , 2011 .

[12]  D. Penney,et al.  Comparison of the acoustic properties of six popular stethoscopes. , 1992, The Journal of the Acoustical Society of America.

[13]  Herbert M. Aumann,et al.  A Radiating Near-Field 24 GHz Radar Stethoscope , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[14]  G. Drzewiecki,et al.  Active and passive stethoscope frequency transfer functions: Electronic stethoscope frequency response , 2014, 2014 IEEE Signal Processing in Medicine and Biology Symposium (SPMB).

[15]  G. El Zein,et al.  Low power microwave systems for heartbeat rate detection at 2.4, 5.8, 10 and 16 GHz , 2008, 2008 First International Symposium on Applied Sciences on Biomedical and Communication Technologies.

[16]  Herbert M. Aumann,et al.  Stethoscope with digital frequency translation for improved audibility , 2019, Healthcare technology letters.

[17]  Yun-Jung Lee,et al.  Modified adaptive noise canceller with an electrocardiogram to enhance heart sounds in the auscultation sounds , 2011 .