Novel real‐time R‐wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions

Electrocardiograph (ECG) triggered or gated magnetic resonance methods are used in many imaging applications. Therefore, a reliable trigger signal derived from to the R‐wave of the ECG is essential, especially in cardiac imaging. However, currently available methods often fail mainly due to the artifacts in the ECG generated by the MR scanner itself, such as the magnetohydrodynamic effect and gradient switching noise. The purpose this study was to characterize the accuracy of selected R‐wave detection algorithms in an MR environment, and to develop novel approaches to eliminate imprecise triggering. Vectorcardiograms (VCG) in 12 healthy volunteers exposed to 1.5 T magnetic field were digitized and used as a reference data set including manually corrected onsets of R‐waves. To define the magnetohydrodynamic effect, the VCGs were characterized in time, frequency, and spatial domains. The selected real‐time R‐wave detection algorithms, and a new “target‐distance” VCG‐based algorithm were applied either to standard surface leads calculated from the recorded VCG or to the VCG directly. The flow related artifact was higher in amplitude than the R‐wave in 28% of the investigated VCGs which yielded up to 9–16%false positive detected QRS complexes for traditional algorithms. The “target‐distance” R‐wave detection algorithm yielded a score of 100% for detection with 0.2% false positives and was superior to all the other selected methods. Thus, the VCG of subjects exposed to a strong magnetic field can be use to separate the magnetohydrodynamic artifact and the actual R‐wave, and markedly improves the trigger accuracy in gated magnetic resonance scans. Magn Reson Med 42:361–370, 1999. © 1999 Wiley‐Liss, Inc.

[1]  H V PIPBERGER,et al.  Correlation of clinical information in the standard 12-lead ECG and in a corrected orthogonal 3-lead ECG. , 1961, American heart journal.

[2]  Willis J. Tompkins,et al.  A Real-Time QRS Detection Algorithm , 1985, IEEE Transactions on Biomedical Engineering.

[3]  J Felblinger,et al.  Amplitude demodulation of the electrocardiogram signal (ECG) for respiration monitoring and compensation during MR examinations , 1997, Magnetic resonance in medicine.

[4]  A T Barker,et al.  The effect of rapid rise-time magnetic fields on the ECG of the rat. , 1982, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[5]  L. Erhardt,et al.  Continuous vectorcardiography in acute myocardial infarction. Natural course of ST and QRS vectors. , 1983, International journal of cardiology.

[6]  L W Hedlund,et al.  Optimizing electrocardiograph electrode placement for cardiac-gated magnetic resonance imaging. , 1987, Investigative radiology.

[7]  H. Pipberger,et al.  The Corrected Orthogonal Electrocardiogram and Vectorcardiogram in 510 Normal Men (Frank Lead System) , 1964, Circulation.

[8]  J Felblinger,et al.  Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering , 1994, Magnetic resonance in medicine.

[9]  F. N. Wilson,et al.  The substitution of a tetrahedron for the Einthoven triangle. , 1947, American heart journal.

[10]  L Guize,et al.  Change in human cardiac rhythm induced by a 2-T static magnetic field. , 1988, Radiology.

[11]  H V PIPBERGER,et al.  Automatic Recognition of Electrocardiographic Waves by Digital Computer , 1961, Circulation research.

[12]  E Kanal,et al.  Burns associated with clinical MR examinations. , 1990, Radiology.

[13]  C. Higgins,et al.  Imaging and characterization of acute myocardial infarction in vivo by gated nuclear magnetic resonance. , 1984, Circulation.

[14]  R E Wendt,et al.  Monitoring of acutely III patients during nuclear magnetic resonance imaging: Use of a Time‐varying filter electrocardiographic gating device to reduce gradient artifacts , 1988, Magnetic resonance in medicine.

[15]  A. Shetty,et al.  Suppression of radiofrequency interference in cardiac gated MRI: A simple design , 1988, Magnetic resonance in medicine.

[16]  P.E. Trahanias,et al.  An approach to QRS complex detection using mathematical morphology , 1993, IEEE Transactions on Biomedical Engineering.

[17]  S. Suppappola,et al.  Nonlinear transforms of ECG signals for digital QRS detection: a quantitative analysis , 1994, IEEE Transactions on Biomedical Engineering.

[18]  B D Fletcher,et al.  Gated magnetic resonance imaging of congenital cardiac malformations. , 1984, Radiology.

[19]  R E Wendt,et al.  Electrocardiographic gating and monitoring in NMR imaging. , 1988, Magnetic resonance imaging.

[20]  J H van Bemmel,et al.  A reference data base for multilead electrocardiographic computer measurement programs. , 1987, Journal of the American College of Cardiology.

[21]  R E Snyder,et al.  RF interference suppression in a cardiac synchronization system operating in a high magnetic field NMR imaging system. , 1988, Magnetic resonance imaging.

[22]  D Kilpatrick,et al.  QRS waveform of ventricular extrasystoles and their differentiation from aberrant conduction. , 1980, Cardiology.

[23]  T F Budinger,et al.  Cardiovascular alterations in Macaca monkeys exposed to stationary magnetic fields: experimental observations and theoretical analysis. , 1983, Bioelectromagnetics.

[24]  Korchevskiĭ Em,et al.  On the magnetic hydrodynamic variant of blood transfer , 1965 .

[25]  M. Evans,et al.  Cardiac performance during pregnancy: serial evaluation using external systolic time intervals. , 1975, American journal of obstetrics and gynecology.

[26]  E Kanal,et al.  Patient monitoring during clinical MR imaging. , 1992, Radiology.

[27]  P. Savard,et al.  On the detection of QRS variations in the ECG , 1995, IEEE Transactions on Biomedical Engineering.

[28]  E. Frank An Accurate, Clinically Practical System For Spatial Vectorcardiography , 1956, Circulation.

[29]  C. Li,et al.  Detection of ECG characteristic points using wavelet transforms. , 1995, IEEE transactions on bio-medical engineering.

[30]  M Bahoura,et al.  DSP implementation of wavelet transform for real time ECG wave forms detection and heart rate analysis. , 1997, Computer methods and programs in biomedicine.

[31]  T F Budinger,et al.  Nuclear Magnetic Resonance (NMR) In Vivo Studies: Known Thresholds for Health Effects , 1981, Journal of computer assisted tomography.

[32]  A. Ruha,et al.  A real-time microprocessor QRS detector system with a 1-ms timing accuracy for the measurement of ambulatory HRV , 1997, IEEE Transactions on Biomedical Engineering.

[33]  G. Dower,et al.  On Deriving the Electrocardiogram from Vectorcardiographic Leads , 1980, Clinical cardiology.

[34]  Michael Nugent,et al.  ASA Monitoring Standards and Magnetic Resonance Imaging , 1994, Anesthesia and analgesia.

[35]  H. T. Nagle,et al.  A comparison of the noise sensitivity of nine QRS detection algorithms , 1990, IEEE Transactions on Biomedical Engineering.

[36]  N. A. Korenevskii,et al.  Automated processing of electrophysiological signals , 1995 .

[37]  S Suppappola,et al.  Automated performance evaluation of real-time QRS-detection devices. , 1995, Biomedical instrumentation & technology.

[38]  R. Poli,et al.  Genetic design of optimum linear and nonlinear QRS detectors , 1995, IEEE Transactions on Biomedical Engineering.

[39]  Y. Geoffrion,et al.  A simple fiber optic monitor of cardiac and respiratory activity for biomedical magnetic resonance applications , 1986, Magnetic resonance in medicine.

[40]  A. Kohút,et al.  Pentoxifylline-associated reduction of indomethacin-induced rat gastric mucosal injury is supported by decreased lipid peroxidation. , 1994, Physiological research.