Determining the infrared reflectance of specular surfaces by using thermographic analysis

Specular surfaces as glass, mirrors and metals are commonly used in solar devices and in building facades. Determining the temperature distribution of such kind of surfaces allows estimating their thermal losses and detecting hot spots and temperature gradients that provokes material stress and rupture. In this sense, thermography is a non-contact measurement technique that is capable to quickly scan and record these surface temperature distributions, but when specular materials are inspected the infrared reflectance becomes a crucial parameter. This work describes a methodology to measure the reflectance of specular materials for different incidence angles in the infrared range 8 μm–14 μm, by using a thermographic camera and an infrared radiation source. The methodology includes the analysis of errors in the estimation of the reflectance and how to select the temperature of the source that minimizes these errors. The method is applied to different specular surfaces commonly used in building facades and solar devices, whose infrared specular reflectances are estimated for different incidence angles. The obtained results are analyzed in order to provide valuable information for in-situ thermographic measurements of specular surfaces.

[1]  Giorgio Baldinelli,et al.  A quantitative methodology to evaluate thermal bridges in buildings , 2012 .

[2]  James F. Schooley,et al.  Temperature : its measurement and control in science and industry , 1992 .

[3]  H. E. Bennett,et al.  Relation between Surface Roughness and Specular Reflectance at Normal Incidence , 1961 .

[4]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[5]  Eckhard Lüpfert,et al.  Infrared temperature measurements on solar trough absorber tubes , 2007 .

[6]  Susumu Hattori,et al.  Establishing a practical temperature standard by using a narrow-band radiation thermometer with a silicon detector , 1983 .

[7]  Sergio Marinetti,et al.  Emissivity estimation for accurate quantitative thermography , 2012 .

[8]  Arno Krenzinger,et al.  Accurate outdoor glass thermographic thermometry applied to solar energy devices , 2007 .

[9]  Deo Prasad,et al.  Thermographic analysis of a building integrated photovoltaic system , 2002 .

[10]  Soteris A. Kalogirou,et al.  Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes , 2011 .

[11]  Eyal Ben-Dor,et al.  Diurnal thermal behavior of selected urban objects using remote sensing measurements , 2004 .

[12]  J. Taylor An Introduction to Error Analysis , 1982 .

[13]  K. Ghazi Wakili,et al.  Effects of individual climatic parameters on the infrared thermography of buildings , 2013 .

[14]  A. Argiriou,et al.  Measurement of brightness concentration distribution in the focal zone of a focusing solar collector with an infrared camera , 1988 .

[15]  C. Véret La Thermographie Infrarouge , 1981 .

[16]  A. Rogalski Recent progress in infrared detector technologies , 2011 .

[17]  Yves Candau,et al.  Improvement of building wall surface temperature measurements by infrared thermography , 2005 .

[18]  Rossano Albatici,et al.  Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site , 2010 .