Development of test facility for compatibility and performance testing of all-digital protection systems connected to IEC 61850-9-2 standard

The development of Intelligent Electronic Devices (IED) have increased the use of digital protection systems, in which the digitized signals replaced the usage of conventional analog signals. The digitized signals are generated at electronic instrument transformers and they are transferred to protection systems over a process bus based on IEC 61850-9-2 standard. This transferring process between electronic instrument transformers and protection systems requires a detailed performance evaluation, analysis, and compatibility of the two different systems, since various vendors' instrument transformers and relays are aimed to be connected. This paper presents a developed test facility for all-digital protection system performance evaluations. Typical power system faults are regenerated with the facility and the performance of the digital systems are investigated. The compatibility of an optical current transformer and a digital relay is analyzed. Digital relay's inverse time delay characteristics are obtained. Results show that all-digital systems provided by different manufacturers can work together and are suitable to protect power systems where protection is needed.

[1]  Rick Kuffel,et al.  Real time simulation and testing using IEC 61850 , 2010, 2010 Modern Electric Power Systems.

[2]  Norman T. Stringer The effect of DC offset on current operated relays , 1997, 1997 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record.

[3]  R.E. Mackiewicz,et al.  Overview of IEC 61850 and Benefits , 2006, 2005/2006 IEEE/PES Transmission and Distribution Conference and Exhibition.

[4]  M. Kezunovic,et al.  Compatibility and interoperability evaluation of all-digital protection systems based on IEC 61850-9-2 communication standard , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[5]  A. Apostolov,et al.  IEC 61850 process bus based distributed waveform recording , 2006, 2006 IEEE Power Engineering Society General Meeting.

[6]  V. Skendzic,et al.  Enhancing Power System Automation Through the Use of Real-Time Ethernet , 2006, 2006 Power Systems Conference: Advanced Metering, Protection, Control, Communication, and Distributed Resources.

[7]  G.G. Karady,et al.  Development of test facility for transmission line protection , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition.

[8]  Hong-Hee Lee,et al.  A study on IEC 61850 based communication for intelligent electronic devices , 2005, Proceedings. The 9th Russian-Korean International Symposium on Science and Technology, 2005. KORUS 2005..

[9]  H.-J. Herrmann,et al.  Impact of decentralized transformer electronics on the protection relay design , 2004 .

[10]  Xianggen Yin,et al.  Research on Protection Equipment with Digital Interface Based on IEC-61850 , 2007, 2007 IEEE Power Engineering Society General Meeting.

[11]  A. Apostolov,et al.  Functional Testing of IEC 61850 Based Protection Relays , 2007, 2007 60th Annual Conference for Protective Relay Engineers.