Automatic ultrasound determination of thermal coagulation front during laser tissue heating

Thermal therapies using laser, microwaves, radio frequency radiation, and high intensity focused ultrasound have shown great promise for minimally invasive treatment of benign and malignant lesions. To treat tissue effectively and safely, techniques that could monitor the advancement of coagulation front during treatment are highly desirable. This paper presents a noninvasive ultrasound technique for automatically determining the propagation of coagulation damage front during laser tissue heating. The basic assumption underlying this technique is that when coagulation is taking place in a tissue, owing to thermally induced structure changes in tissue, the waveform of echo signal scattered from that treated region should be changing accordingly. We first track echoes scattered from many small tissue regions during heating using a cross-correlation echo-tracking technique. We then use the waveform-change information to determine the position of coagulation front via an automatic calculation procedure. To test our technique, we carried out 35 experiments in which we irradiated fresh canine liver samples with a Nd:YAG laser (1064-nm wavelength) at various light fluence (62 to 167 W/cm/sup 2/) and exposure time (20 to 350 s). A 13-mm diameter 10-MHz broadband single-element spherical focused ultrasound transducer was used to detect the thermal coagulation front. The root mean square difference between ultrasonically and visually determined coagulation depths was 0.77 mm. This good agreement between visually inspected and ultrasonically determined coagulation depths shows the potential of our technique for monitoring coagulative tissue damage during thermal therapy.

[1]  G. Clifford Carter Coherence and time delay estimation : an applied tutorial for research, development, test, and evaluation engineers , 1993 .

[2]  W. O’Brien,et al.  Experimental verification of theoretical in vivo ultrasound heating using cobalt detected magnetic resonance , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Yoshimi Anzai,et al.  MR imagin—histopathologic correlation of thermal injuries induced with interstitial Nd:YAG laser irradiation in the chronic model , 1992, Journal of magnetic resonance imaging : JMRI.

[4]  Jeffrey D. Robinson,et al.  Interstitial laser phototherapy assisted by magnetic resonance imaging: A new technique for monitoring laser‐tissue interaction , 1990, The Laryngoscope.

[5]  Nasser Kehtarnavaz,et al.  Ultrasound imaging to track the advance of coagulation front in laser irradiated tissue , 1996, Proceeding of Southwest Symposium on Image Analysis and Interpretation.

[6]  M Motamedi,et al.  Ultrasonic Doppler detection of laser-tissue interaction. , 1994, Ultrasound in medicine & biology.

[7]  F. Duck Physical properties of tissue , 1990 .

[8]  Z. Sun,et al.  A multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: theory and computer simulation. , 1999, Ultrasonics.

[9]  D E MALONE,et al.  Sonographic Changes during Hepatic Interstitial Laser Photocoagulation: An Investigation of Three Optical Fiber Tips , 1992, Investigative radiology.

[10]  G Godlewski,et al.  Ultrasonic and histopathological correlations of deep focal hepatic lesions induced by stereotaxic Nd-YAG laser applications. , 1988, Ultrasound in medicine & biology.

[11]  Clarence E. Carter Tutorial Overview of Coherence and Time Delay Estimation , 1993 .

[12]  R. Watkins,et al.  One‐Dimensional NMR Thermal Mapping of Focused Ultrasound Surgery , 1994, Journal of computer assisted tomography.

[13]  R. Seip,et al.  Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound , 1995, IEEE Transactions on Biomedical Engineering.

[14]  T Misaki,et al.  Thermally Controlled Laser Irradiation of the Myocardium with Intraoperative Ultrasound Monitoring , 1990, Pacing and clinical electrophysiology : PACE.

[15]  J. Ophir,et al.  The combined effect of signal decorrelation and random noise on the variance of time delay estimation , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Julius S. Bendat,et al.  Engineering Applications of Correlation and Spectral Analysis , 1980 .

[17]  A. Dachman,et al.  US-guided percutaneous laser ablation of liver tissue in a chronic pig model. , 1990, Radiology.

[18]  W. Walker,et al.  A fundamental limit on delay estimation using partially correlated speckle signals , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  W R Lees,et al.  Hepatic metastases: interstitial laser photocoagulation with real-time US monitoring and dynamic CT evaluation of treatment. , 1993, Radiology.

[20]  G. Carter Coherence and time delay estimation , 1987, Proceedings of the IEEE.

[21]  Glenn M. Preminger Video-Assisted Transurethral Resection of the Prostate , 1991 .

[22]  H. Fukukita,et al.  Ultrasound thermometry in hyperthermia , 1990, IEEE Symposium on Ultrasonics.

[23]  B. Hooper Optical-thermal response of laser-irradiated tissue , 1996 .

[24]  C. Damianou,et al.  Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical model. , 1996, The Journal of the Acoustical Society of America.

[25]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[26]  K. Hynynen,et al.  Tissue thermometry during ultrasound exposure. , 1993, European urology.

[27]  C. Damianou,et al.  Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study. , 1996, The Journal of the Acoustical Society of America.

[28]  Guanrong Chen,et al.  Real-time ultrasound-guided fuzzy control of tissue coagulation progress during laser heating , 2000, Inf. Sci..

[29]  F. Jolesz,et al.  Tissue temperature monitoring for thermal interventional therapy: Comparison of T1‐weighted MR sequences , 1994, Journal of magnetic resonance imaging : JMRI.

[30]  A. Weiss,et al.  Fundamental limitations in passive time delay estimation--Part I: Narrow-band systems , 1983 .

[31]  D. R. Wyman,et al.  Medical imaging systems for feedback control of interstitial laser photocoagulation , 1992, Proc. IEEE.