Offshore Wind Power Generation Technologies

This paper provides an overview of the current state of the technology of offshore wind-based power generation and the technological challenges with emphasis on the electrical parts. First, a brief review of the core control functions, their correlation with operational behavior, and the grid-supporting capability of the machine during normal operation as well as during contingency situations are provided. This is followed by the discussion of basic considerations in wind farm collector design, including topology, grounding options, and outlay of the offshore substation. Then, issues related to offshore turbine foundation and typical dimensions of the offshore substation platform are discussed. The platform is designed to accommodate the main and grounding transformers, the switch gear, and other assorted accessories. Next, options for the transmission link from the offshore plant to the grid onshore are reviewed. Finally, a discussion of issues related to grid integration together with currently applicable special grid code requirements concludes the paper.

[1]  Istvan Erlich,et al.  Protection system behavior of DFIG based wind farms for grid-faults with practical considerations , 2010, IEEE PES General Meeting.

[2]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[3]  W.L. Kling,et al.  Transmission expansion issues for offshore wind farms integration in Europe , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition.

[4]  M. Seidel,et al.  Jacket substructures for the REpower 5M wind turbine , 2007 .

[5]  C. Feltes,et al.  High voltage ride-through of DFIG-based wind turbines , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[6]  I. Erlich,et al.  Impact of large offshore wind farms on power system transient stability , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[7]  I. Erlich,et al.  Grid code requirements concerning connection and operation of wind turbines in Germany , 2005, IEEE Power Engineering Society General Meeting, 2005.

[8]  Lothar Fickert,et al.  Improved Protection system for electrical components in wind energy plants , 2006 .

[9]  I. Erlich,et al.  Dynamic Behavior of DFIG-Based Wind Turbines during Grid Faults , 2007, 2007 Power Conversion Conference - Nagoya.

[10]  J. G. Slootweg,et al.  Wind Power: Modelling and Impact on Power System Dynamics , 2003 .

[11]  I. Erlich,et al.  Neutral grounding in wind farm medium voltage collector grids , 2011, 2011 IEEE/PES Power Systems Conference and Exposition.

[12]  I. Erlich,et al.  Modeling of Wind Turbines Based on Doubly-Fed Induction Generators for Power System Stability Studies , 2007, IEEE Transactions on Power Systems.

[13]  Graham Ault,et al.  Electrical collector system options for large offshore wind farms , 2007 .

[14]  I. Erlich,et al.  Advanced grid requirements for the integration of wind turbines into the German transmission system , 2006, 2006 IEEE Power Engineering Society General Meeting.

[15]  I. Erlich,et al.  Enhanced Fault Ride-Through Method for Wind Farms Connected to the Grid Through VSC-Based HVDC Transmission , 2009, IEEE Transactions on Power Systems.

[16]  Hermann Koch,et al.  Connecting large offshore wind farms to the transmission network , 2010, IEEE PES T&D 2010.

[17]  J. Holboell,et al.  Energization of Wind Turbine Transformers With an Auxiliary Generator in a Large Offshore Wind Farm During Islanded Operation , 2011, IEEE Transactions on Power Delivery.

[18]  Lennart Söder,et al.  Wind power grid integration: The European experience , 2011 .