Determination of mechanical properties of human femoral cortical bone by the Hopkinson bar stress technique.

The Hopkinson bar stress technique and a universal testing machine (Instron 1125) have been used to investigate the dynamic and static mechanical properties of cortical bone taken from a human femur respectively. We found that the average dynamic Young's modulus value (Ed = 19.9 GPa) to be 23% higher than the average static Young's modulus value (Ed = 16.2 GPa). Furthermore, the Poisson's ratio did not exhibit any significant variation for the two different types of loading. No difference was observed between the values of the dynamic Young's modulus in tension and those found in compression. A comparison was made of the results of this study with those found by other researchers using different techniques, such as ultrasonics, and it was found that they agree well with most of the results of previous studies. Finally, the viscosity for cortical bone found in this study correlates with viscosity reported by Tennyson et al. [Expl Mech. 12, 502-507 (1972)] for ten days post mortem age specimens.

[1]  S. Lang,et al.  Ultrasonic method for measuring elastic coefficients of bone and results on fresh and dried bovine bones. , 1970, IEEE transactions on bio-medical engineering.

[2]  William Bonfield,et al.  Deformation and Fracture of Bone , 1966 .

[3]  A. Gjelsvik,et al.  Mechanical properties of hydrated cortical bone. , 1974, Journal of biomechanics.

[4]  M. S. King,et al.  Determination of Elastic Constants for Human Femurs , 1979 .

[5]  R. Pelker,et al.  Stress wave propagation in bone. , 1983, Journal of biomechanics.

[6]  A. Burstein,et al.  The elastic modulus for bone. , 1974, Journal of biomechanics.

[7]  E. F. Byars,et al.  EFFECT OF EMBALMING ON THE MECHANICAL PROPERTIES OF BEEF BONE. , 1964, Journal of applied physiology.

[8]  R. S. Nelson Focused collision sequences in tungsten and molybdenum , 1963 .

[9]  J. Mcelhaney,et al.  Dynamic response of bone and muscle tissue. , 1966, Journal of applied physiology.

[10]  A Simkin,et al.  The mechanical testing of bone in bending. , 1973, Journal of biomechanics.

[11]  H. Kolsky,et al.  LXXI. The propagation of stress pulses in viscoelastic solids , 1956 .

[12]  Fracture of notched and perforated polymeric bars produced by longitudinal impact , 1979 .

[13]  W. Abendschein,et al.  Ultrasonics and selected physical properties of bone. , 1970, Clinical orthopaedics and related research.

[14]  D D Raftopoulos,et al.  Static and dynamic mechanical and optical behaviour of high polymers , 1976 .

[15]  W C Van Buskirk,et al.  Ultrasonic measurement of orthotropic elastic constants of bovine femoral bone. , 1981, Journal of biomechanical engineering.

[16]  A. Burstein,et al.  The biomechanics of torsional fractures: the effect of loading on ultimate properties. , 1971, Journal of biomechanics.

[17]  J L Lewis,et al.  The dynamic fracture and prefracture response of compact bone by split Hopkinson bar methods. , 1975, Journal of biomechanics.

[18]  W. Goldsmith,et al.  A biaxial split Hopkinson bar for simultaneous torsion and compression , 1973 .

[19]  A. Burstein,et al.  The elastic and ultimate properties of compact bone tissue. , 1975, Journal of biomechanics.

[20]  J. Katz,et al.  Ultrasonic wave propagation in human cortical bone--II. Measurements of elastic properties and microhardness. , 1976, Journal of biomechanics.

[21]  E. Sedlin,et al.  A rheologic model for cortical bone. A study of the physical properties of human femoral samples. , 1965, Acta orthopaedica Scandinavica. Supplementum.

[22]  W C Van Buskirk,et al.  A continuous wave technique for the measurement of the elastic properties of cortical bone. , 1984, Journal of biomechanics.

[23]  R. C. Tennyson,et al.  Dynamic viscoelastic response of bone , 1972 .