Reevaluating Reconstruction Filters for Path‐Searching Tasks in 3D

In this paper, we present an experiment on stereoscopic direct volume rendering, aiming at understanding the relationship between the choice of reconstruction filter and participant performance on tasks requiring spatial understanding such as 3D path‐searching. The focus of our study is on the impact on task performance of the post‐aliasing and smoothing produced by the reconstruction filters. We evaluated five reconstruction filters, each under two different transfer functions and two different displays with a wide range of behaviours in terms of post‐aliasing and smoothing. We found that path‐searching tasks commonly found in the literature, and as the one we employed here, elicit bias in the responses which should be taken into account when analysing the results. Our analysis, which employed both standard statistical tests and techniques from signal detection theory, indicates that the choice of reconstruction filter affects some aspects of the spatial understanding of the scene.

[1]  R. Hamer,et al.  Effects of age and optical blur on real depth stereoacuity , 2010, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[2]  Timo Ropinski,et al.  Supporting Depth and Motion Perception in Medical Volume Data , 2008, Visualization in Medicine and Life Sciences.

[3]  Jonathan D. Pfautz,et al.  Depth Perception in Computer Graphics , 2000 .

[4]  Timo Ropinski,et al.  About the Influence of Illumination Models on Image Comprehension in Direct Volume Rendering , 2011, IEEE Transactions on Visualization and Computer Graphics.

[5]  Timo Ropinski,et al.  Visually Supporting Depth Perception in Angiography Imaging , 2006, Smart Graphics.

[6]  Doug A. Bowman,et al.  Effects of VR System Fidelity on Analyzing Isosurface Visualization of Volume Datasets , 2014, IEEE Transactions on Visualization and Computer Graphics.

[7]  D. Louis Collins,et al.  An Evaluation of Depth Enhancing Perceptual Cues for Vascular Volume Visualization in Neurosurgery , 2014, IEEE Transactions on Visualization and Computer Graphics.

[8]  William Ribarsky,et al.  Evaluating depth perception of volumetric data in semi-immersive VR , 2012, AVI.

[9]  Timo Ropinski,et al.  Interactive volumetric lighting simulating scattering and shadowing , 2010, 2010 IEEE Pacific Visualization Symposium (PacificVis).

[10]  Arun N. Netravali,et al.  Reconstruction filters in computer-graphics , 1988, SIGGRAPH.

[11]  Terry M. Peters,et al.  Visual Enhancement of MR Angiography Images to Facilitate Planning of Arteriovenous Malformation Interventions , 2015, TAP.

[12]  Stéphane Ploix,et al.  A perceptive evaluation of volume rendering techniques , 2007, TAP.

[13]  M. Unser,et al.  Interpolation Revisited , 2000, IEEE Trans. Medical Imaging.

[14]  Steve Marschner,et al.  An evaluation of reconstruction filters for volume rendering , 1994, Proceedings Visualization '94.

[15]  Ingrid Carlbom,et al.  Optimal filter design for volume reconstruction and visualization , 1993, Proceedings Visualization '93.

[16]  Roger J. Hubbold,et al.  Autostereoscopic display for radiotherapy planning , 1997, Electronic Imaging.

[17]  Eric D. Ragan,et al.  Studying the Effects of Stereo, Head Tracking, and Field of Regard on a Small-Scale Spatial Judgment Task , 2013, IEEE Transactions on Visualization and Computer Graphics.

[18]  William Ribarsky,et al.  Stereo and motion cues effect on depth perception of volumetric data , 2014, Electronic Imaging.

[19]  Eliot Winer,et al.  Assessment of visual-spatial skills in medical context tasks when using monoscopic and stereoscopic visualization , 2013, Medical Imaging.

[20]  Ioannis Ivrissimtzis,et al.  An evaluation of reconstruction filters for a path-searching task in 3D , 2014, 2014 Sixth International Workshop on Quality of Multimedia Experience (QoMEX).

[21]  Leonid I. Dimitrov,et al.  Enhanced Voxelization and Representation of Objects with Sharp Details in Truncated Distance Fields , 2010, IEEE Transactions on Visualization and Computer Graphics.

[22]  Thierry Blu,et al.  Generalized interpolation: Higher quality at no additional cost , 1999, Proceedings 1999 International Conference on Image Processing (Cat. 99CH36348).

[23]  Neil A. Macmillan,et al.  Detection Theory: A User's Guide , 1991 .

[24]  Nikolaus F. Troje,et al.  Enhancing Depth Perception in Translucent Volumes , 2006, IEEE Transactions on Visualization and Computer Graphics.

[25]  Colin Ware,et al.  Evaluating stereo and motion cues for visualizing information nets in three dimensions , 1996, TOGS.

[26]  David Hawkes,et al.  Surface transparency makes stereo overlays unpredictable: the implications for augmented reality. , 2003, Studies in health technology and informatics.

[27]  Paolo Fiorini,et al.  Evaluation of force and torque magnitude discrimination thresholds on the human hand-arm system , 2010, TAP.

[28]  David S. Ebert,et al.  Interactive volume illustration and feature halos , 2003, 11th Pacific Conference onComputer Graphics and Applications, 2003. Proceedings..

[29]  Ioannis P. Ivrissimtzis,et al.  Quality measures of reconstruction filters for stereoscopic volume rendering , 2016, Computational Visual Media.

[30]  Johan H. C. Reiber,et al.  The effect of stereoscopy and motion cues on 3D interpretation task performance , 2010, AVI.

[31]  David H. Laidlaw,et al.  Effects of Stereo and Screen Size on the Legibility of Three-Dimensional Streamtube Visualization , 2012, IEEE Transactions on Visualization and Computer Graphics.

[32]  Balázs Csébfalvi,et al.  An Evaluation of Prefiltered Reconstruction Schemes for Volume Rendering , 2008, IEEE Transactions on Visualization and Computer Graphics.

[33]  Mathias Schott,et al.  Evaluation of Depth of Field for depth perception in DVR , 2013, 2013 IEEE Pacific Visualization Symposium (PacificVis).

[34]  Stefan Bruckner,et al.  Enhancing Depth-Perception with Flexible Volumetric Halos , 2007, IEEE Transactions on Visualization and Computer Graphics.

[35]  M. Unser,et al.  Interpolation revisited [medical images application] , 2000, IEEE Transactions on Medical Imaging.

[36]  Nicolas S. Holliman,et al.  Investigating the performance of path-searching tasks in depth on multiview displays , 2010, TAP.

[37]  Davide Rocchesso,et al.  Auditory distance perception in an acoustic pipe , 2008, TAP.

[38]  Andrea Giachetti,et al.  An interactive 3D medical visualization system based on a light field display , 2009, The Visual Computer.

[39]  Pere-Pau Vázquez,et al.  Depth-Enhanced Maximum Intensity Projection , 2010, VG@Eurographics.

[40]  Colin Ware,et al.  Reevaluating stereo and motion cues for visualizing graphs in three dimensions , 2005, APGV '05.

[41]  Timo Ropinski,et al.  Interactive Volume Rendering with Dynamic Ambient Occlusion and Color Bleeding , 2008, Comput. Graph. Forum.

[42]  A BowmanDoug,et al.  Validation of the MR Simulation Approach for Evaluating the Effects of Immersion on Visual Analysis of Volume Data , 2012 .