A comparison of three different adaptive strategies in image-guided radiotherapy of bladder cancer

Abstract The urinary bladder shows considerable individual variation in shape and position during a course of radiotherapy (RT). In this study we have developed and compared three different adaptive RT (ART) strategies for bladder cancer involving daily cone beam CT (CBCT) imaging and plan selection. Material and methods. Ten patients treated for bladder cancer had daily CBCTs acquired that were registered online using bony anatomy registration. Seven patients received intensity modulated RT (IMRT) with a simultaneous integrated boost (SIB) technique to the bladder and pelvic lymph nodes. Three patients received treatment to the bladder only. Retrospectively, we compared three ART strategies that were all based on daily selection of the most suitable plan from a library consisting of three IMRT-plans corresponding to a small, medium and large target volume. ART method A utilised population-based margins while methods B and C used the bladder as seen on CBCT-scans from the first week of treatment; method B without delineation of the bladder on CBCT and method C with delineation of the bladder. Total dose distributions were calculated using the planning CT. For each patient, we calculated ratios of the dose volume histograms (DVHs) for the three ART strategies relative to non-adaptive therapy. Results. The inter-patient variation was large for all three ART strategies. The mean ratios of the volumes receiving 57 Gy or more (corresponding to 95% of prescribed dose) for methods A, B and C were 0.66 (SD: 0.11), 0.67 (SD: 0.13) and 0.67 (SD: 0.16) respectively when compared to the non-adaptive plan. Conclusion. When using any of the ART strategies, it is possible to reduce significantly the volumes receiving high doses compared to the use of a standard non-adaptive plan. The differences in dose volume parameters between the three methods were small compared with the differences from the standard plan.

[1]  Y. Kvinnsland,et al.  Testing the new ICRU 62 'Planning Organ at Risk Volume' concept for the rectum. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  Kari Tanderup,et al.  Acceleration and validation of optical flow based deformable registration for image-guided radiotherapy , 2008, Acta oncologica.

[3]  Lawrence B Marks,et al.  Integral dose conservation in radiotherapy. , 2009, Medical physics.

[4]  Christopher J Moore,et al.  Assessment of bladder motion for clinical radiotherapy practice using cine-magnetic resonance imaging. , 2009, International journal of radiation oncology, biology, physics.

[5]  M. V. van Herk,et al.  Tumor motion and deformation during external radiotherapy of bladder cancer. , 2006, International journal of radiation oncology, biology, physics.

[6]  D. Yan,et al.  Adaptive radiation therapy , 1997, Physics in medicine and biology.

[7]  G. Sanguineti,et al.  Dose-volume effects for normal tissues in external radiotherapy: pelvis. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  Peter Remeijer,et al.  Adaptive management of bladder cancer radiotherapy. , 2010, Seminars in radiation oncology.

[9]  C. Grau,et al.  A study of image-guided radiotherapy of bladder cancer based on lipiodol injection in the bladder wall , 2010, Acta oncologica.

[10]  L. Muren,et al.  The contribution of on-line correction for rotational organ motion in image-guided radiotherapy of the bladder and prostate , 2008, Acta oncologica.

[11]  Marcel van Herk,et al.  Lipiodol injection for target volume delineation and image guidance during radiotherapy for bladder cancer. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  J. Petersen,et al.  The normal tissue sparing obtained with simultaneous treatment of pelvic lymph nodes and bladder using intensity-modulated radiotherapy , 2009, Acta oncologica.

[13]  Ludvig Paul Muren,et al.  Propagation of target and organ at risk contours in radiotherapy of prostate cancer using deformable image registration , 2010, Acta oncologica.

[14]  Ludvig Paul Muren,et al.  An optimisation algorithm for determination of treatment margins around moving and deformable targets. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Young-Bin Cho,et al.  Inter- and intrafractional tumor and organ movement in patients with cervical cancer undergoing radiotherapy: a cinematic-MRI point-of-interest study. , 2008, International journal of radiation oncology, biology, physics.

[16]  D Verellen,et al.  Conformal arc radiotherapy for prostate cancer: increased biochemical failure in patients with distended rectum on the planning computed tomogram despite image guidance by implanted markers. , 2009, International journal of radiation oncology, biology, physics.

[17]  Peter Remeijer,et al.  Adaptive radiotherapy for invasive bladder cancer: a feasibility study. , 2005, International journal of radiation oncology, biology, physics.

[18]  L. Muren,et al.  CT-guided intensity-modulated radiotherapy for bladder cancer: isocentre shifts, margins and their impact on target dose. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  L. Muren,et al.  A method to individualize adaptive planning target volumes for deformable targets , 2009, Physics in medicine and biology.

[20]  Cai Grau,et al.  The normal tissue sparing potential of adaptive strategies in radiotherapy of bladder cancer , 2008, Acta oncologica.

[21]  Alexandra Aitken,et al.  Cone beam computed tomography-derived adaptive radiotherapy for radical treatment of esophageal cancer. , 2010, International journal of radiation oncology, biology, physics.

[22]  C. Grau,et al.  Image-guided adaptive radiotherapy – integration of biology and technology to improve clinical outcome , 2008, Acta oncologica.