Smooth Muscle-Dependent Changes in Aortic Wall Dynamics during Intra-Aortic Counterpulsation in an Animal Model of Acute Heart Failure

Purpose Intra-aortic balloon pumping (IABP) may modify arterial biomechanics; however, its effects on arterial wall properties during acute cardio-depression have not yet been fully explored. This dynamical study was designed to characterize the effects of IABP on aortic wall mechanics in an in vivo animal model of acute heart failure. Methods Aortic pressure, diameter and blood flow were measured in six anesthetized sheep with acute cardio-depression by halothane (4%), before and during IABP (1:2). Aortic characteristic impedance and aortic wall stiffness indexes were calculated. Results Acute experimental cardio-depression resulted in a reduction in mean aortic pressure (p<0.05) and an increase in the characteristic impedance (p<0.005), incremental elastic modulus (p<0.05), stiffness index (p<0.05) and Peterson elastic modulus (p<0.05). IABP caused an increase in the cardiac output (p<0.005) and a reduction in the systemic vascular resistances (p<0.05). In addition, the aortic impedance, incremental elastic modulus, stiffness index and Peterson modulus were significantly reduced during IABP (p<0.05). Conclusions Our findings show that IABP caused changes in aortic wall impedance and intrinsic wall properties, improving the arterial functional capability and the left ventricular afterload by a reduction in both. Systemic vascular resistances and aortic stiffness were also improved by means of smooth muscle-dependent mechanisms.

[1]  Alain Simon,et al.  Endothelium-dependent arterial wall tone elasticity modulated by blood viscosity. , 2002, American journal of physiology. Heart and circulatory physiology.

[2]  G. Mancia,et al.  Sympathetic modulation of radial artery compliance in congestive heart failure. , 1995, Hypertension.

[3]  E de Forteza,et al.  Adventitia‐dependent mechanical properties of brachiocephalic ovine arteries in in vivo and in vitro studies , 2006, Acta physiologica.

[4]  Susanna Price,et al.  Intra-aortic balloon pumping: effects on left ventricular diastolic function. , 2003, European Journal of Cardio-Thoracic Surgery.

[5]  A. Montoya,et al.  Arterial impedance in patients during intraaortic balloon counterpulsation. , 1996, The Annals of thoracic surgery.

[6]  L. Hillis,et al.  Intra-aortic balloon counterpulsation. , 2006, The American journal of cardiology.

[7]  Daniel Bia Santana,et al.  Pulmonary artery smooth muscle activation attenuates arterial dysfunction during acute pulmonary hypertension. , 2005, Journal of applied physiology.

[8]  N. Marchionni,et al.  Effective arterial elastance and the hemodynamic effects of intraaortic balloon counterpulsation in patients with coronary heart disease. , 1998, American heart journal.

[9]  Aortic function in patients during intra-aortic balloon pumping determined by the pressure-diameter relation. , 1998, The Journal of thoracic and cardiovascular surgery.

[10]  D. Bia,et al.  Increased reversal and oscillatory shear stress cause smooth muscle contraction‐dependent changes in sheep aortic dynamics: role in aortic balloon pump circulatory support , 2008, Acta physiologica.

[11]  R. Zelis,et al.  Alterations in vasomotor tone in congestive heart failure. , 1982, Progress in cardiovascular diseases.

[12]  Ghassan S. Kassab,et al.  Proper Orientation of the Graft Artery Is Important to Ensure Physiological Flow Direction , 2006, Annals of Biomedical Engineering.

[13]  R. Armentano,et al.  Effects of Intra-Aortic Counterpulsation on Aortic Wall Energetics and Damping: In Vivo Experiments , 2008, ASAIO journal.

[14]  E. C. Fischer,et al.  A new approach to assist postoperative heart failure in an animal model: juxta-aortic counterpulsation. , 2002, Artificial organs.

[15]  R. Armentano,et al.  Differential functional coupling between human saphenous cryoallografts and arteries: importance of the arterial type and the biomechanical parameter evaluated. , 2007, Artificial organs.

[16]  R. Armentano,et al.  Assessment of smooth muscle contribution to descending thoracic aortic elastic mechanics in conscious dogs. , 1993, Circulation research.

[17]  Alain Simon,et al.  Mechanical Pressure Versus Intrinsic Effects of Hypertension on Large Arteries in Humans , 1991, Hypertension.

[18]  Kimon S Stamatelopoulos,et al.  New aspects on the role of blood pressure and arterial stiffness in mechanical assistance by intra-aortic balloon pump: in-vitro data and their application in clinical practice. , 2004, Artificial organs.

[19]  T. Spray,et al.  Myocardial depression by anesthetic agents (halothane, enflurane and nitrous oxide): quantitation based on end-systolic pressure-dimension relations. , 1984, The American journal of cardiology.

[20]  A. Carpentier,et al.  Temporary Mechanical Circulatory Support for Severe Cardiac Failure: Experimental Study , 1991, The International journal of artificial organs.

[21]  D. Sigg,et al.  In vivo versus in vitro comparison of swine cardiac performance: induction of cardiodepression with halothane. , 2006, European journal of pharmacology.

[22]  W S Pierce,et al.  Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure. , 1999, The Journal of thoracic and cardiovascular surgery.

[23]  R. Armentano,et al.  Arterial wall mechanics in conscious dogs. Assessment of viscous, inertial, and elastic moduli to characterize aortic wall behavior. , 1995, Circulation research.

[24]  R. Reneman,et al.  Properties of the arterial wall: practice , 2011 .